首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   55篇
  免费   1篇
化学   35篇
物理学   21篇
  2022年   2篇
  2021年   1篇
  2016年   1篇
  2015年   1篇
  2013年   2篇
  2012年   4篇
  2011年   3篇
  2010年   6篇
  2009年   2篇
  2008年   3篇
  2007年   5篇
  2006年   9篇
  2005年   4篇
  2004年   4篇
  2003年   1篇
  1998年   1篇
  1995年   2篇
  1993年   1篇
  1992年   1篇
  1991年   1篇
  1984年   1篇
  1982年   1篇
排序方式: 共有56条查询结果,搜索用时 0 毫秒
31.
32.
We report on the first measurement of the triangular v3, quadrangular v4, and pentagonal v5 charged particle flow in Pb-Pb collisions at sqrt(s(NN)) = 2.76 TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show that the triangular flow can be described in terms of the initial spatial anisotropy and its fluctuations, which provides strong constraints on its origin. In the most central events, where the elliptic flow v2 and v3 have similar magnitude, a double peaked structure in the two-particle azimuthal correlations is observed, which is often interpreted as a Mach cone response to fast partons. We show that this structure can be naturally explained from the measured anisotropic flow Fourier coefficients.  相似文献   
33.
The centrality dependence of the charged-particle multiplicity density at midrapidity in Pb-Pb collisions at sqrt[s_{NN}]=2.76 TeV is presented. The charged-particle density normalized per participating nucleon pair increases by about a factor of 2 from peripheral (70%-80%) to central (0%-5%) collisions. The centrality dependence is found to be similar to that observed at lower collision energies. The data are compared with models based on different mechanisms for particle production in nuclear collisions.  相似文献   
34.
4,4??-biphenylene spaced lipophilic bis-??-diketone ligands of the type 4,4??-bis(RC(O)CH2C(O))C12H8 (R = Pr, Ph, hexyl, octyl, nonyl) have been prepared and used for the liquid?Cliquid extraction of d-block metal ions. These ligands are expected to interact with divalent metal ions to form charge-neutral trinuclear metallocycles of type [M3(L 3 )3(solvent)] as has been demonstrated with the previously reported derivative of H2 L 3 (R =  t Bu), the X-ray structure of which is reported. Liquid?Cliquid extraction studies were performed in a two-phase water/chloroform system employing a radiotracer technique for cobalt(II) and zinc(II). These experiments involved the systematic variation of ligand, metal and 4-ethylpyridine concentrations to probe the stoichiometries of the species extracted. Synergistic extraction was observed when 4-ethylpyridine was present with the ligand in the organic phase. Competitive extraction studies demonstrated the ligands are highly selective for copper(II) over cobalt(II), nickel(II), zinc(II) and cadmium(II).  相似文献   
35.
A simple, fast, efficient and reproducible method for peptide separations in CZE is reported. It consists in running tryptic digests of peptides in an uncoated capillary, in a BGE composed of tetraborate as a buffering ion, in which the typical sodium counterion is substituted with barium. Efficient absorption of this divalent cation to ionized silanols and barium silicate precipitation seem to be able to shield effectively the silica surface from separands. This is demonstrated by the fact that, when tBa(2+) ions are present in solution (from pH 8.5 up to pH 11.0), the electroendoosmotic flow is reversed; such reversal being progressively higher at higher pH values, by up to a four-fold. Separations become progressively better at higher pH values, whereas at pH 11 in sodium tetraborate they are dramatically worsened. It is further hypothesized that the barium silicate layer further protects the silica surface against dissolution and corrosion which is quite substantial at pH 11.  相似文献   
36.
To study the molecular mass distribution and number of species in narrow-range (2-pH-unit wide, in the nominal pI 2-4 or 3-5 interval) carrier ampholytes from four commercial sources (Bio-Lyte, Servalyt, Ampholine and Pharmalyte), a 2-D technique was adopted, consisting of a preparative focusing step in a Rotofor instrument, followed by analysis of every other collected fraction (10 out of 20) by CE-MS. It was found that Ampholine pH 3.5-5 contains 105 different molecular mass (M(r)) compounds, in the M(r) interval 205-965 Da, for a total of 446 isoforms. Bio-Lyte pH 3-5 consists of 84 different M(r) species, in the M(r) range 216-965 Da, for a total of 383 isoforms. Servalyt pH 2-4 is made of 227 different M(r) compounds, in the M(r) interval 204-929 Da, for a total of 1201 isoforms. Pharmalyte pH 2.5-5 comprises 245 amphoteres, in the M(r) range 203-857 Da, for a total of 857 isoforms. Pharmalyte appears to be the best brand, with the vast majority of species focusing sharply at their pI position and almost no 'poor' species, distributed along the entire pH gradient, denoting an extremely shallow pH/mobility curve across the pI value. Due to some overlap with the adjacent acidic pH 4-6 interval, the species in common have been evaluated: the most extended overlaps are found in Ampholine (55% of the species appearing in the two neighbouring intervals) and in Servalyt (47% coincidence). The lowest overlaps are found in Pharmalyte (23%) and in Bio-Lyte (20%).  相似文献   
37.
In horses, there is an increasing interest in developing long-lasting drug formulations, with biopolymers as viable carrier alternatives in addition to their use as scaffolds, suture threads, screws, pins, and plates for orthopedic surgeries. This communication focuses on the prolonged biocompatibility and biodegradation of PLA, prepared by hot pressing at 180 °C. Six samples were implanted subcutaneously on the lateral surface of the neck of one horse. The polymers remained implanted for 24 to 57 weeks. Physical examination, plasma fibrinogen, and the mechanical nociceptive threshold (MNT) were performed. After 24, 28, 34, 38, and 57 weeks, the materials were removed for histochemical analysis using hematoxylin-eosin and scanning electron microscopy (SEM). There were no essential clinical changes. MNT decreased after the implantation procedure, returning to normal after 48 h. A foreign body response was observed by histopathologic evaluation up to 38 weeks. At 57 weeks, no polymer or fibrotic capsules were identified. SEM showed surface roughness suggesting a biodegradation process, with an increase in the median pore diameter. As in the histopathological evaluation, it was not possible to detect the polymer 57 weeks after implantation. PLA showed biocompatible degradation and these findings may contribute to future research in the biomedical area.  相似文献   
38.
A trinuclear metallo-capsule has been assembled from a new tripodal pyridyl ligand and three silver(I) ions; the X-ray structure shows the presence of a Ag-Ag interaction in the solid state giving rise to a non-symmetric capsule arrangement while NMR evidence indicates that the structure in solution is symmetrical.  相似文献   
39.
Polytetrafluoroethylene (PTFE) latices with spherical and rod‐like particles in the submicrometer size range, were employed as seeds in the emulsifier‐free methylmethacrylate (MMA) emulsion polymerization to obtain PTFE‐polymethylmethacrylate (PMMA) core‐shell nanoparticles. Stable latices were generally obtained. No residual PTFE was found at the end of the reaction. By appropriately choosing the ratio between MMA and PTFE in the reaction mixture, particles with predetermined size and monodisperse or narrow size distribution were prepared. The high structural regularity of the core‐shell samples allows the preparation of film with a periodic distribution of the cores thus ultimately leading to a well structured 2D colloidal crystal. A very peculiar crystallization behavior was observed because of the PTFE compartmentalization in the composite. © 2009 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 47: 2928–2937, 2009  相似文献   
40.
A novel method for performing 2‐D map analysis is here reported, consisting in a modification of the second dimension run, which is performed not in a conventional square‐ or rectangular‐size gel, but in a radial surface. This has the advantage of permitting resolution of closely adjacent bands, representing strings of isoforms of similar or identical mass but of closely spaced isoelectric points. When used in a mono‐dimensional, SDS‐PAGE format, this system allows the simultaneous running of 62 sample tracks. Examples are given of separation of plasma and urinary proteins.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号