首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
  国内免费   1篇
化学   10篇
力学   3篇
物理学   4篇
  2019年   1篇
  2018年   1篇
  2012年   2篇
  2011年   2篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2006年   2篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
排序方式: 共有17条查询结果,搜索用时 15 毫秒
11.
We report observations on a chiral nematic liquid crystal confined in a plane cell treated for homeotropic alignment. The characteristics of the specimen investigated are such that at room temperature a uniform homeotropic alignment is observed and at higher temperatures the material displays the helical structure. It is observed that the changeover between homeotropic and helical textures does not occur at one single threshold. There are two thresholds, between which there is an intermediate texture where small circular domains are observed. These domains may be regarded as circular analogues of the plane solitons predicted by previous authors.  相似文献   
12.
13.
A sensitive and specific luminescence method for the determination of Fexofenadine (FEX), in pharmaceutical formulations is reported. The method is based on the sensitization of terbium (Tb3+) by complex formation with FEX. The luminescence signal for Tb–FEX complex is greatly enhanced by the addition of triethylamine (ET3N) and zinc nitrate in methanol solution. Monitoring of the signal is accomplished when the instrument is in the phosphorescence mode with the excitation and emission wavelengths set at λex = 220 nm and λem = 550 nm respectively. Optimum conditions for the formation of the complex in methanol were 2.25 × 10?6 M of Tb3+, 5.00 × 10?6 M of Et3N and Zn2+ which allows for the determination of 10–800 ppb of FEX in the batch mode with a detection limit of 0.3 ppb. The proposed method was successfully applied for the determination of FEX in pharmaceutical formulations.  相似文献   
14.
The effect of detection chip geometry on chemiluminescence (CL) signal intensity of tris(1,10-phenanthroline)-ruthenium(II) peroxydisulphate system for analysis of chlorpheniramine maleate (CPM) in pharmaceutical formulations was investigated. It was observed that the design of the detection chip is very crucial and can play an important role in enhancing the CL signal intensity in this system. The CL signal intensity was enhanced 250% when a teardrop micromixer chip was used, compared to the commonly used serpentine chip geometry. The study was conducted using a multi-chip device. In this device, chip 1 was used to prepare and pump the reagent mixture, whereas chip 3 was used for pumping the sample. The two chips were connected to the teardrop chip (2) via silica capillary where detection took place. Non-linear regression curve fitting of the calibration data revealed that the calibration curves are best described by third order polynomial equation with excellent correlation coefficients (R2 = 0.9998) for the concentration range 7.69 × 10−8 to 5.12 × 10−5 mol L−1. A linear response is also observed over the range 7.69 × 10−8 to 1.28 × 10−5 mol L−1 (R2 = 0.9996) and the detection limit was found to be 5.49 × 10−8 mol L−1. The device was successfully used for the analysis of CPM in tablets and a multi-component cough syrup. Results were reproducible with relative standard deviation (RSD) of 0.6-1.1%.  相似文献   
15.
A sensitive time- resolved luminescence method for the determination of meloxicam (MX) in methanol and in aqueous solution is described. The method is based on the luminescence sensitization of europium (Eu3+) by formation of ternary complex with MX in the presence of 1,10- phenanthroline as coligand, Tween-80 as surfactant and gadolinium ion as a co-luminescence reagent. The signal for Eu- MX-1, 10- phenanthroline is monitored at λex = 360 nm and λem = 620 nm. Optimum conditions for the formation of the complex in aqueous system were 0.01 M TRIS buffer, pH 8.0, 1,10- phenanthroline (6.0 × 10−6 M) , Gd3+ (7.0 × 10−6 M), Tween-80 (0.28%) and 1.75 mM of Eu3+ which allows the determination of 20–800 ppb of MX with limit of detection (LOD) of 7 ppb. The relative standard deviations of the method range between 0.1 and 1.1% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assay of MX in pharmaceutical formulations, plasma and in urine samples. Average recoveries of 99.8 ± 1.1%, 100.2 ± 0.9% and 100.9 ± 1.1% were obtained for MX in tablet, plasma and urine sample respectively.  相似文献   
16.
A fast, economic and sensitive chemiluminescence (CL) method has been developed for the analysis of cetrizine hydrochloride (CET) in pharmaceutical formulations and in biological fluids. The CL method is based on the oxidation of tris(2,2′-bipyridyl)ruthenium(II) (Ru (bipy)32+) by peroxydisulphate in a two-chip device. Up to 180 samples can be analysed per hour, consuming only minute quantities of reagents. Three instrumental setups were tested to find the most economical, sensitive and high throughput setup. In the first setup, a continuous flow of sample and CL reagents was used, whereas in the second setup, a fixed volume (2 μL) of (Ru (bipy)32+) was introduced into a continuous infusion of peroxydisulphate and the sample. In the third design, a fixed volume of sample (2 μL) was injected while the CL reagents were continuously infused. Compared to the first setup, a 200% signal enhancement was observed in the third setup. Various parameters that influence the CL signal intensity, including pH, flow rates and reagent concentrations, were optimized. A linear response was observed over the range of 50 μg L−1 to 6400 μg L−1 (R2 = 0.9959) with RSD values of 1.1% (n = 15) for 1000 μg L−1. The detection limit was found to be 15 μg L−1 (S/N = 3). The amount of consumed sample was only 2 μL, from which the detected amount of CET was found to be 6.5 × 10−14 mol. This procedure was successfully applied to the analysis of CET in pharmaceutical formulations and biological fluids.  相似文献   
17.
A sensitive and a selective spectrofluorimetric method have been developed for the rapid determination of trace levels of zinc. The method is based on complex formation between zinc and 3-hydroxyflavone (3HF), which displays an intense emission signal around 478 nm. The analytical performance of the method was examined by considering the factors that affect the complex formation such as pH, mole ratio of the metal and solvent type. The optimum conditions for the complex formation were metal to ligand stoichiometric ratio of 1:1 at pH 7.5 with 0.1 M Tris buffer. Under these conditions the detection limit attained was 1.5 ppb. The method was appropriately validated and yielded relative standard deviations of less than 2% (n = 5), which was considered acceptable. It was successfully applied to the trace determination of zinc in drinking water, hair shampoo and pharmaceutical samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号