排序方式: 共有76条查询结果,搜索用时 15 毫秒
51.
52.
53.
在同步辐射装置3W1B光束线上测量了软X射线能区50~200 eV金属W薄膜的反射率,并采用最小二乘拟合得到其光学常量.实验采用三种样品:Si衬底单层W超薄膜,Si衬底W/C双层膜,SiO2衬底W薄膜.分别获得金属W光学常量,三种样品的结果分别代表W薄膜光学常量,WC薄膜结合中W薄膜的光学常量及体材料W的光学常量.结果表明,前两者结果与以往发表数据一致性较好,第三种样品的结果则更接近已发表的体材料的结果.通过实验结果和已发表数据的比较,发现随着薄膜厚度的降低,光学常量实部(色散因子)变化不明显,而虚部(吸收因子)随之升高.实验不确定度来源于光谱纯净度和光源稳定性. 相似文献
54.
55.
A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multilayer has been designed, constructed, and installed in 3W1B at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-transmission, front-reflection-behind-transmission and front-transmission-behind-reflection, have been realized. It can be used for the polarization analysis of synchrotron radiation. It also can be used to characterize the polarization properties of the optical elements in the soft X-ray energy range. Some experiments with Mo/Si and Cr/C multilayers have been performed by using this polarimeter with good results obtained. 相似文献
56.
对研制的安装在合肥国家同步辐射实验室(NSRL)计量光束线上的VUV/EUV标准探测器装置进行了传输标准探测器的首次标定工作.实验选取了3个能点17.625nm,6.8nm和92nm,在这3个能点处分别标定光电二极管,得到其相应的量子效率.结果表明在同一能点多次标定结果的重复一致性很好,相对标准偏差在1%—14%的水平;但是与美国国家标准计量局(NIST)标定过的光电二极管的量子效率比较,短波17.625nm的标定结果较好,而6.8nm和92nm波长的结果差距偏大.偏差主要来自光源稳定性和光谱纯净度的影响. 相似文献
57.
58.
X射线胶片是电磁内爆模拟技术研究(Z-pinch)中辐射图像记录的重要媒质.本文针对Z-pinch辐射特性,采用特殊方法制备了兼具大的高感颗粒、略小的中感颗粒和更小的低感颗粒的氯-溴-碘化银微晶乳剂,并使各不同粒径微晶具有特定的晶型和分布几率,调控涂布工艺参数,得到分辨率较高、宽容度大的软X射线胶片(LLSXF).利用北京同步辐射装置作光源,测试了该胶片的宽容度值,并分析了影响宽容度的因素. 相似文献
59.
Measurement of the polarization for soft X-ray magnetic circular dichroism at the BSRF beamline 4B7B
Three ultra-short-period W/B4C multilayers (1.244 nm, 1.235 nm and 1.034 nm) have been fabricated and used for polarization measurement at the 4B7B Beamline at the Beijing Synchrotron Radiation Facility (BSRF). By using the rotating analyzer ellipsometry method, the linear polarization degree of light emerging from this beamline has been measured and the circular polarization evaluated for 700-860 eV. The first soft X-ray magnetic circular dichroism measurements are carried out at BSRF by positioning the beamline aperture out of the plane of the electron storage ring. 相似文献
60.
软X光平面镜反射率标定实验 总被引:9,自引:3,他引:6
报道了掠入射软X光平面镜反射率标定实验。实验利用北京同步辐射装置 (BSRF) 3W 1B束线及反射率计靶室 ,在束流 35mA~ 110mA、贮存环电子能量 2GeV专用光运行模式下 ,在 5 0eV~ 85 0eV能区分四个能段 ,进行了 5°掠入射Ni平面镜反射率标定实验。标定过程中用高灵敏度无死层的硅光二极管代替X射线二极管作探测器 ,输出信号提高 2~ 3个量级 ,可标定能区从 15 0eV~ 2 70eV拓展到 5 0eV~ 85 0eV ,给出了完整的 5°Ni平面镜反射率标定曲线。最后把实验数据与理论计算作了比对并进行了分析。 相似文献