排序方式: 共有26条查询结果,搜索用时 281 毫秒
1.
简要叙述了稠密等离子体聚焦装置作为中子发生器的工作原理,对影响稠密等离子体聚焦装置放电出中子产额及其稳定性的一些因素和改进措施进行了简单讨论.通过使用不同电极形状的场畸变开关很好地提高了焦点装置的运行,使装置输出中子的起伏得到明显的改善.通过对腔内电极的清洁,在不更换气体的条件下,聚焦装置放电出中子产额稳定.The principle of dense plasma focus(DPF) as neutron generator has been investigated in this paper. We have stated briefly some factors that mainly influnce the DPF s neutron yield and some methods improving the stability of neutron yields on the dense plasma focus. It is showed that the fluctuation of DPF output neutron becomes smaller by using different types of field-distortion elements. Over 100 consecutive shots without purging the test gas the neutron yields has no obvious change. 相似文献
2.
稠密等离子体聚焦装置的中子产额及其稳定性研究 总被引:1,自引:0,他引:1
叙述了稠密等离子体聚焦装置(DPF)作为中子发生器的工作原理,讨论了影响DPF中子产额及其稳定性的一些因素和改进措施。利用不同电极形状、不同绝缘气体的场崎变开关可以很好地提高聚焦装置的运行性能,使装置输出中子的起伏由过去的约两个量级降到目前的3倍左右。通过对腔内电极的清洁,在不更换气体的条件下。中子产额无明显下降。 相似文献
3.
建立了一套门控闪烁测量系统(门控ST-PMT系统), 测量了稠密等离子体聚焦(DPF)波形后沿中子峰下3~4个量级的物理图像, 分别讨论了长电缆对 DPF D-D, D-T中子峰下3~4个量级波形测量的影响, 采用数学方法分析了长电缆作为频率滤波函数在解逆卷积函数中的应用, 解析了电缆带宽对测量结果的影响。The influence of the Fourier Transform on long cable in the measurement of fall time of DPF neutron profile is discussed by mathematical methods. The application of anti convolution function with the Fourier Transform on long cable is analysed. The time interval between the peak time and the time that the height falls 3 orders of magnitude after peak is measured with gated detector array system which consists of PMT(photomultiplier tube) and organic scintillation crystal. 相似文献
4.
5.
用CeF3闪烁体和常用闪烁体ST401分别配特性相同的光电倍增管构成两种闪烁探测器,在1.2MeV、2.5MeV、3.5MeV、5.0MeV和14MeV等能量的稳态中子源场中,测量了这两种闪烁体探测器的电流输出,得到结果表明:上述能量的中子与CeF3闪烁探测器作用形成的电流比同尺寸ST401闪烁体构成探测器的输出电流均低一个量级以上,这些结果与这两种探测器在钴、铯γ源中测量结果比较,可以得出在n、γ混合辐射场中测量γ辐射时,CeF3闪烁探测器能够较好地屏蔽这些能量中子的干扰. 相似文献
6.
7.
大面积PIN探测器性能参数实验测量 总被引:1,自引:0,他引:1
利用CFC-67型三通道γ源加速器测量了Ф50mm,Ф60mmPIN探测器的时间响应、线性电流及相对灵敏度,并与理论计算结果进行了比较,验证了实验结果的可靠性。Ф60 mm silicon PIN detector is a large area and high sensitive one which has been developed in near years. Using the type CГC-67 γ accelerator, the parameters of PIN detectors such as time response, linear current and relative sensitivity are measured. The experiment results are compared with the theory calculation. The PIN detector can reach high γefficiency of up to 10^-14-10^-16 C·cm2, the rise time is about 10 ns and the FWHM of the time pulse is about 35 ns. The γ efficiency of the PIN detector may provide the sensitive range between 10^-14-10^-16 C·cm^2 that scintillator + photo tubes detecting system and scintillator + photomul tiplier tubes detecting system is not developed. 相似文献
8.
当样品含有多种能量的γ射线时,某一峰下的面积,不仅记录了该能量的光电效应事件,而且还包括了更高能量γ射线的Compton 散射事件。这样,就不能由峰下面积确定相应的γ射线强度,采用逆矩阵法对γ能谱进行分析可得到较好非结果。When the sample contains many kinds of energies γ rays,their peak’s area not only records the matters of optical electronic effect but also the Compton scattering matters with higher energyγ rays.So that,theγ rays intensity conducted by the peak’s area can’t gain.Using the anti-matrix method,the better results of anlyze on theγ Spectrometry may be getten. 相似文献
9.
10.
The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices.A compact MPR-type spectrometer dedicated to the research of pulsed deuterium-tritium(DT)neutron spectroscopy of special experimental conditions is currently under design.Analyses of the main parameters and performance of the magnetic analysis system through 3-D particle transport calculations and MonteCarlo simulations and calibration of the system performance as a test using CR-39 solid track detector and α particle from 239pu and 226Ra radioactive sources are presented in this paper.The results indicate that the magnetic analysis system will achieve a detection efficiency level of 10-5-10-4 at an energy resolution of 1.5%-2.1%,and fulfills the design goals of the spectrometer. 相似文献