排序方式: 共有65条查询结果,搜索用时 0 毫秒
31.
对近代物理研究所建成的用于研究高电荷态离子与原子碰撞中多电子转移过程的符合关联实验测量系统;该系统的飞行时间谱仪、位置灵敏探测器、多参数数据获取系统分别进行了介绍;给出了利用加速器提供的离子束Ar12+→Ar调试的反冲氩离子飞行时间谱仪和O2→He离子束调试位置灵敏探测器的实验结果,给出了104keV的Ar8++Ar碰撞的最新实验结果,并对Ar8++Ar反应的二维关联谱的结果进行了分析,研究鉴定了这一碰撞反应中的多电子转移过程和残余气体引起的多次碰撞. 相似文献
32.
33.
汶伟强 马新文 张大成 朱小龙 孟令杰 李杰 刘惠萍 赵冬梅 王之帅 毛瑞士 赵铁成 武军霞 马晓明 晏太来 李国宏 杨晓东 刘勇 杨建成 原有进 夏佳文 徐瑚珊 肖国青 赵红卫 《中国物理 C》2013,37(10)
The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP. For an RF-bunched ion beam, a longitudinal momentum spread of Δp/p=1.6×10-5 has been reached with less than 107 stored ions. The reduction of momentum spread compared with a coasting ion beam was observed from Schottky noise signal of the bunched ion beam. In order to prepare the future laser cooling experiment at the CSRe, the RF-bunching power was modulated at 25th, 50th and 75th harmonic of the revolution frequency, effective bunching amplitudes were extracted from the Schottky spectrum analysis. Applications of Schottky noise for measuring beam lifetime with ultra-low intensity of ion beams are presented, and it is relevant to upcoming experiments on laser cooling of relativistic heavy ion beams and nuclear physics at the CSRe. 相似文献
34.
为了在CSRm的电子冷却器上进行辐射复合以及双电子复合实验, 需要探测能量小于4 MeV/u的离子, 因此设计了新的置于超高真空环境的CsI(Tl)闪烁探测器, 探测器采用的光电倍增管为R7525(Hamamatsu)。 介绍了新闪烁探测器的结构, 并对其进行了性能测试。 测试结果表明, 该探测器对高、 低能离子均有良好的响应, 探测器的信号十分明显。 探测器的最高计数率可以达到106 ions/s, 并且探测器附近的真空度可达10-10 Pa量级, 能够满足辐射复合与双电子复合实验以及储存环对真空的要求, 为今后在CSRm上进行复合实验打下了良好的基础。 A new CsI(Tl) scintillation detector readout with R7525 PMT(Hamamatsu)is designed to detect low energy (<4 MeV/u) ions in radiative recombination and dielectronic recombination experiments at the main cooler storage ring in Lanzhou. The structure of the scintillator detector is described in this paper. The detector is tested with α source and ion beams, respectively. The signals from background, 200 MeV/u C6+ and alpha radioactive source are recorded and analyzed. The results show that the detector has good response to high and low energy ions. The maximum counting rate of the detector can reach 106 ions/s and the vacuum level near the detector can reach 10-10 Pa, both are good for recombination experiments. The installation of the new detector to CSRm is of great help for future radiative recombination and dielectronic recombination experiments. 相似文献
35.
36.
37.
38.
39.
测量了入射离子能量为27 keV、45 keV和66 keV时Ar3 Ar碰撞反应各子过程的分截面,通过将其归一化到Bliman,Dousson等人所测量的截面值,获得了绝对截面.结果表明,该能区电子俘获过程仍占主导地位,但转移电离过程已不能忽略.结果还表明,各子过程反应截面基本不随能量变化.与考虑自电离的MCBM(Molecular Coulombic overBarrier Model)模型比较发现,模型所给截面普遍高于实验测量值,这在一定程度上是由于归一化时带来的系统误差.在误差允许的范围内,单电子和双电子俘获截面符合的比较好,但三电子俘获截面却相差一个数量级.对于实验观测到的转移电离过程,模型却预言并没有此过程发生. 相似文献
40.