首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   0篇
化学   24篇
数学   1篇
  2023年   1篇
  2021年   1篇
  2020年   1篇
  2019年   1篇
  2016年   1篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2011年   4篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   2篇
  2006年   1篇
  2004年   2篇
  2003年   3篇
  2002年   2篇
排序方式: 共有25条查询结果,搜索用时 29 毫秒
11.
The present paper describes a novel method for the quantitative determination of inorganic arsenic (iAs) in food and feed of marine origin. The samples were subjected to microwave-assisted extraction using diluted hydrochloric acid and hydrogen peroxide, which solubilised the analytes and oxidised arsenite (As(III)) to arsenate (As(V)). Subsequently, a pH buffering of the sample extract at pH 6 enabled selective elution of As(V) from a strong anion exchange solid-phase extraction (SPE) cartridge. Hydride generation atomic absorption spectrometry (HG-AAS) was applied to quantify the concentration of iAs (sum of As(III) and As(V)) as the total arsenic (As) in the SPE eluate. The results of the in-house validation showed that mean recoveries of 101-104% were achieved for samples spiked with iAs at 0.5, 1.0 and 1.5 mg·kg(-1), respectively. The limit of detection was 0.08 mg kg(-1), and the repeatability (RSD(r)) and intra-laboratory reproducibility (RSD(IR)) were less than 8% and 13%, respectively, for samples containing 0.2 to 1.5 mg kg(-1) iAs. The trueness of the SPE HG-AAS method was verified by confirming results obtained by parallel analysis using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry. It was demonstrated that the two sets of results were not significantly different (P < 0.05). The SPE HG-AAS method was applied to 20 marine food and feed samples, and concentrations of up to 0.14 mg kg(-1) of iAs were detected.  相似文献   
12.
Brix R  Spliid H  Hansen SH  Sørensen E 《The Analyst》2002,127(12):1676-1681
In this paper the process from experimental design (e.g. ruggedness test) to uncertainty estimation is described. The uncertainty estimate was calculated for the peak area of insulin plus A21 desamido insulin resulting from an HPLC analysis of a sample of an injectable human insulin preparation, Actrapid HM 100 IU ml(-1) (Novo Nordisk A/S). The analytical method used was the European Pharmacopoeia assay. (4) An expanded uncertainty (1) of 1.8% (of the area from the HPLC analysis) at an approximately 95% confidence level was found and confirmed by a validation study. This uncertainty refers to the peak area of the analyte from a single injection of the sample. The input parameters to the uncertainty estimate were found from a factorial experimental design (e.g. ruggedness test) consisting of 9 factors applied to the HPLC analysis. The input parameters were chosen to cover the probable contributors to the variability of the measured area of the HPLC analysis, including the sample preparation, but excluding uncertainty deriving from the reference material(s).  相似文献   
13.
A library of blood coagulation factor Xa (FXa)-trypsin hybrid proteases was generated and displayed on phage for selection of derivatives with the domain "architecture" of trypsin and the specificity of FXa. Selection based on binding to soybean trypsin inhibitor only provided enzymatically inactive derivatives, due to a specific mutation of serine 195 of the catalytic triad to a glycine, revealing a significant selection pressure for proteolytic inactive derivatives. By including a FXa peptide substrate in the selection mixture, the majority of the clones had retained serine at position 195 and were enzymatically active after selection. Further, with the inclusion of bovine pancreatic trypsin inhibitor, in addition to the peptide substrate, the selected clones also retained FXa specificity after selection. This demonstrates that affinity selection combined with appropriate deselection provides a simple strategy for selection of enzyme derivatives that catalyse a specific reaction.  相似文献   
14.
During the development of an on‐line solid phase extraction‐liquid chromatography‐ultraviolet detection (SPE‐LC‐UV) analytical method for determination of eight selected triazines; ametryn, atrazine, cyanazine, metrybuzine, prometryn, propazin, simazine, and terbutryn, in drinking water, it was observed that the retention times of three of them (ametryn, prometryn, and terbutryn) in Milli‐Q water were different from those in chlorinated Milli‐Q water, indicating the formation of new products. The cause of this change was found in the oxidation of the molecules as a result of chlorination with sodium hypochlorite. Experiments performed at varying concentrations of triazines and hypochlorite showed that the extent of the reaction depended on their relative concentrations. At the maximum admissible level of 100 ng/l for individual pesticides in drinking water, no apparent transformation was observed in the absence or at low concentrations (0.05 mg/l) of hypochlorite; however, on increasing the concentration of hypochlorite to the level typically present in drinking water (0.9 mg/l) the transformation was complete. The reaction is quite fast; within 1 h the parent compound is completely degraded and after 22 h the concentrations of the by‐products are constant. Investigation of the by‐products by ultra performance liquid chromatography‐quadrupole‐time of flight‐ tandem mass spectrometry (UPLC‐Q‐ToF‐MS/MS) has shown that all three triazines follow a similar transformation pathway, forming four new molecules whose structure have been elucidated. The acute toxicity of the new products was investigated using a standard method based on the bioluminescence inhibition of Vibrio fischeri, and the by‐products showed a higher toxicity than that of the parent compounds. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   
15.
The content of total and inorganic arsenic was determined in 16 dietary supplements based on herbs, other botanicals and algae purchased on the Danish market. The dietary supplements originated from various regions, including Asia, Europe and USA. The contents of total and inorganic arsenic was determined by inductively coupled plasma mass spectrometry (ICP-MS) and anion exchange HPLC-ICP-MS, respectively, were in the range of 0.58 to 5.0 mgkg?1 and 0.03 to 3.2 mg?kg?1, respectively, with a ratio between inorganic arsenic and total arsenic ranging between 5 and 100 %. Consumption of the recommended dose of the individual dietary supplement would lead to an exposure to inorganic arsenic within the range of 0.07 to 13 μg?day?1. Such exposure from dietary supplements would in worst case constitute 62.4 % of the range of benchmark dose lower confidence limit values (BMDL01 at 0.3 to 8 μg kg bw?1 kg?1 day?1) put down by European Food Safety Authority (EFSA) in 2009, for cancers of the lung, skin and bladder, as well as skin lesions. Hence, the results demonstrate that consumption of certain dietary supplements could contribute significantly to the dietary exposure to inorganic arsenic at levels close to the toxicological limits established by EFSA.  相似文献   
16.
17.
This paper presents the development, optimization, and validation of a LC-MS/MS methodology to determine the concentration of the antifungal drug and fungicide tebuconazole in a controlled exposure study of African clawed frogs (Xenopus laevis). The method is validated on animal tank water and on tissue from exposed and non-exposed adult X. laevis. Using solid-phase extraction (SPE), the analytical method allows for quantification of tebuconazole at concentrations as low as 3.89 pg mL?1 in 10 mL water samples. Using bead-beating-assisted matrix solid-phase dispersion (MSPD), it was possible to quantify tebuconazole down to 0.63 pg mg?1 wet weight liver using 150 mg tissue. The deuterated analogue of tebuconazole was used as internal standard, and ensured method accuracy in the range 80.6–99.7 % for water and 68.1–109 % for tissue samples. The developed method was successfully applied in a 4-week X. laevis repeated-exposure study, revealing high levels of tebuconazole residues in adipose and liver tissue, and with experimental bioconcentration factors up to 18,244 L kg?1.  相似文献   
18.
Uncertainty budgets can be used for a variety of situations, e.g. reporting the total uncertainty, calculating tolerance limits or method optimisation. In this paper it is demonstrated how the use of uncertainty budgets can help in reducing the total uncertainty of an analytical method, i.e. method optimisation. In this example it has been possible to reduce the total uncertainty of a concentration determination of hydrogen peroxide (by titration) from 2.7 x 10(-2) M to 3.93 x 10(-3) M (or to about a 1/7) by changing the traceability chain and working with more pure reagents.  相似文献   
19.
An attempt is made to revisit the main theoretical considerations concerning temperature effects ("Joule heating") in electro-driven separation systems, in particular lab-on-a-chip systems. Measurements of efficiencies in microfabricated devices under different Joule heating conditions are evaluated and compared to both theoretical models and measurements performed on conventional capillary systems. The widely accepted notion that planar microdevices are less susceptible to Joule heating effects is largely confirmed. The heat dissipation from a nonthermostatically controlled glass microdevice was found to be comparable to that from a liquid-cooled-fused silica capillary. Using typically dimensioned glass and glass/silicon microdevices, the experimental results indicate that 5-10 times higher electric field strengths can be applied than on conventional capillaries, before detrimental effects on the separation efficiency occur. The main influence of Joule heating on efficiency is via the establishment of a radial temperature profile across the lumen of the capillary or channel. An overall temperature increase of the buffer solution has only little influence on the quality of the separation. Still, active temperature control (cooling, thermostatting) can help prevent boiling of the buffer and increase the reproducibility of the results.  相似文献   
20.
Estrogens have been often identified as the major contributors to the endocrine-disrupting activity observed in environmental waters. However, their analysis in these, sometimes very complex, matrices is still challenging due to the very low detection limits and the selectivity required for their reliable determination at the very low concentrations at which they are physiologically active. In this work, a polyclonal enzyme-linked immunosorbent assay (ELISA) kit for 17-beta-estradiol analysis, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) based on triple-quadrupole analyzer (QqQ), and a newly developed method based on ultra performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-Q-TOF-MS) have been evaluated in terms of performance for the rapid screening, quantitative analysis, and unequivocal identification of some selected, environmentally relevant estrogens in different water matrices, including urban wastewater, river water, and ground water, after solid phase extraction. Compounds quantified and/or identified included the estrogens 17-beta-estradiol, estrone, 17-alpha-ethynyl estradiol and estriol, and the isoflavones daidzein, genistein, and biochanin A. Except for a moderate overestimation using the ELISA kit, especially in the analysis of complex wastewater samples, results obtained by all the investigated techniques were in very good, general agreement. The instrumental sensitivity achieved increased in the order: UPLC-Q-TOF-MS < polyclonal ELISA kit < HPLC-MS/MS (QqQ). Direct analysis of water samples by using the ELISA kit permitted to reach a limit of detection of 2.5 ng L(-1). However, using an appropriated sample pretreatment method detection limits at nanogram to picogram per liter levels can be obtained with all techniques and the risk for matrix effects is minimized. In terms of selectivity, both HPLC-MS/MS (QqQ) and UPLC-Q-TOF-MS show outstanding performance, but the latter allows, in addition, shorter analysis times (16 min vs. 45 min) and the identification of non-target, unknown compounds. The identification of unknown compounds is based on the accurate mass measurements for the precursor and product ions, that permit the elemental compositions calculation and the chemical structures to be identified searching against different databases.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号