Reactions in the gas phase of the 13- and 15-electron radical anions [Cr(CO)3]? ˙ and [Cr(CO)4]? ˙ with a series of 27 aldehydes, ketones, esters and ethers have been examined. Sequential alkane eliminations and metal-bonded CO ligand displacements were the principal reactions identified for the RCHO/[Cr(CO)3]? ˙ systems with the latter reaction also common to the RCHO/[Cr(CO)4]? ˙ systems. While [Cr(CO)4]? ˙ was generally unreactive towards ketones R · R'CO, the principal products identified for [Cr(CO)3]? ˙/ketone reactions were the metal-decarbonylated species, respectively [R · R'CO · Cr(CO)x]? ˙ with x = 0–3, and [R · (R' - H2)CO · Cr(CO)2]? ˙. The reaction of [Cr(CO)3]? ˙ with esters RCOOR' proceeds via metal insertion into the alkoxy C? O bond to give end products of the type [R'O · Cr · R(CO)2]? and [R'O? Cr(CO)3]? while the sole ionic products of dialkyl ether/[Cr(CO)3]? ˙ reactions were identified as the alkoxytricarbonylchromium species [RO · Cr(CO)3]?. 相似文献
Periodic DFT and combined quantum mechanics/interatomic potential function (QM-pot) models were used to describe the interaction of CO with the Cu+ sites in FER. The CO stretching frequencies were calculated using omega(CO)(CCSD(T))/r(CO)(DFT) scaling method relating frequencies determined using a high-level quantum-chemical (coupled clusters) method for simple model carbonyls to CO bond lengths calculated using periodic DFT and QM-pot methods for the Cu+-zeolite system. Both periodic DFT and QM-pot models together with omega(CO)/r(CO) scaling describe the CO stretching dynamics with the "near spectroscopic accuracy", giving nu(CO) = 2156 cm(-1) in excellent agreement with experimental data. Calculations for various Cu+ sites in FER show that both types of Cu+ sites in FER (channel-wall sites and intersection sites) have the same CO stretching frequencies. Thus, the CO stretching frequencies are not site-specific in the CO/Cu+/FER system. The convergence of the results with respect to the model size was analyzed. When the same exchange-correlation functional is used the adsorption energies from periodic DFT and QM-pot are in good agreement (about 2 kcal/mol difference) but substantially larger than those of the experiment. The adsorption energy calculated with the B3LYP functional agrees with available experimental data. The overestimation of the adsorption energy in DFT calculations (periodic or QM-pot) is related to a red-shift of the CO stretching mode, both result from an underestimation of the HOMO(5sigma)-LUMO(2pi) gap of CO and the consequent overestimation of the Cu(+)(d)-CO(2pi*) back-donation. For the adsorption energy, this can be overcome by the use of hybrid B3LYP exchange-correlation functional. For the frequency calculations, the DFT problem can be overcome by the use of the omega(CO)(CCSD(T))/r(CO)(DFT) correlation. 相似文献
The sol-gel method was used to prepare two different starting gels containing SiCH3-groups for the preparation of SiOC ceramics. To understand the role of Si—H bonds in the incorporation of carbon into the SiOC network, gels prepared from a 1:2 mixture of triethoxysilane and methyldiethoxysilane (THDH2) and solely methyltriethoxysilane (TMe) were investigated. Thermogravimetric analysis coupled with mass spectroscopy (TG-MS) in inert atmosphere was performed to attain an insight into the decomposition reactions involved during gel-glass transformation. Samples calcined at different temperatures up to 1000°C were characterized by 29Si and 13C magic angle spinning nuclear magnetic resonance (MAS-NMR) spectroscopy. The presence of SiH groups in the starting gel allows an efficient conversion of Si—CH3 groups into CSi4 sites at lower temperatures. As a result, despite a much lower amount of carbon in the starting THDH2 gel (C/Si = 0.33) compared to the TMe gel (C/Si = 1), the amount of carbon inserted into the SiOC network of both glasses is equivalent, but the TMe sample contains the 10 fold amount of free carbon. 相似文献
An improved version of the disposable multichannel immunochemical biosensor for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) based on a screen-printed amperometric transducer and monoclonal antibodies (MAb) against 2,4-D is reported. Entrapment within a thin Nafion film was used for the direct immobilization of MAb at the electrode surface. The amount of the tracer (2,4-D conjugated to acetylcholinesterase) bound in a competitive immunochemical reaction was determined amperometrically using acetylthiocholine iodide as substrate. The measuring procedure (times of incubation with tracer and substrate, pH, tracer concentration) was optimized. The sensor was able to detect less than 0.01 μg/L of free 2,4-D in water. One analysis (8 samples) was completed in 30 min (20 min for immunochemical reaction, 5 min incubation with substrate, 5 min measurement). The performance of the immunosensor (two configurations) was evaluated on real samples (tap water) with added 2,4-D. The determined amounts (mean values 0.097 to 0.105 and 0.89 to 1.13) corresponded well with the added contents of 2,4-D (0.100 and 1.00 μg/L, respectively). 相似文献
A new and fast high-performance liquid chromatography (HPLC) method using technology of fused-core columns for separation of fenoxycarb and cis-, trans-permethrin has been developed and used for their determination in antiparasitic veterinary shampoo. Separation of insecticides and internal standard sudan II was achieved on the fused-core column Ascentis Express RP-Amide (100 × 3.0 mm), particle size 2.7 μm, with mobile phase acetonitrile/water (55:45, v/v) at a flow rate of 1.0 mL min−1 and at temperature 60 °C. The detection wavelength of detector was set at 225 nm for both compounds and internal standard sudan II. Under the optimum chromatographic conditions standard calibration curves were measured with good linearity [r2 = 0.99991 for fenoxycarb, r2 = 0.99987 for trans-permethrin, and r2 = 0.99984 for cis-permethrin (n = 8)]. Commercial samples of antiparasitic veterinary shampoo were extracted with ethanol in ultrasound bath for 5 min. A 2-μL sample volume of the filtered solution was directly injected into the HPLC system. Accuracy of the method defined as a mean recovery of insecticides from shampoo matrix was in the range 100.43–103.85 % for both insecticides.
Low‐temperature generation of P‐nitroxyl phosphane 2 (Ph2POTEMP), which was obtained by the reaction of Ph2PH ( 1 ) with two equivalents of TEMPO, is presented. Upon warming, phosphane 2 decomposed to give P‐nitroxyl phosphane P‐oxide 3 (Ph2P(O)OTEMP) as one of the final products. This facile synthetic protocol also enabled access to P‐sulfide and P‐borane derivatives 7 and 13 , respectively, by using Ph2P(S)H ( 6 ) or Ph2P(BH3)H ( 11 ) and TEMPO. Phosphane sulfide 7 revealed a rearrangement to phosphane oxide 8 (Ph2P(O)STEMP) in CDCl3 at ambient temperature, whereas in THF, thermal decomposition of sulfide 7 yielded salt 10 ([TEMP‐H2][Ph2P(S)O]). As well as EPR and detailed NMR kinetic studies, indepth theoretical studies provided an insight into the reaction pathways and spin‐density distributions of the reactive intermediates. 相似文献
Acrylamide and acrolein are two short-chained hazardous compounds with neurotoxic, carcinogenic, and mutagenic effects. The aim of this paper is to describe a fast and simple procedure for simultaneous determination of both acrylamide and acrolein under standard conditions, suggest a suitable calibration protocol for custom analysis, and demonstrate its applicability to the analysis of gaseous products from, e.g., cigarettes, cigars, or electronic cigarettes. A gas chromatography–mass spectrometry (GC–MS) method was developed to quantify acrylamide and acrolein in smoke vapor from electronic cigarettes, tobacco cigarettes, and cigars. Nonionic and highly polar molecules with a low boiling point and molecular mass need a suitable derivatization method to achieve appropriate retention and selectivity on commonly used relatively nonpolar stationary phases and to enhance the molecular mass for easy MS detection. The derivatization of acrylamide and acrolein was carried out by a bromination method with elemental bromine. The dibromo derivatives were extracted into an organic solvent and following a dehydrobromination procedure the samples were injected into the GC–MS system. Important experimental parameters were varied, after which the bromination time was defined as 30 min, and the injector temperature and the starting temperature of gradient were set at 280 and 50 °C respectively. Acrolein was found in all tested samples, while acrylamide was detected only in smoke from normal tobacco. Possible mechanisms for the formation of these unsaturated compounds in the samples are discussed. After its validation the newly developed method was successfully and reliably applied to the analysis of both compounds. This short method provides an easy way to determine acrylamide and acrolein in gaseous samples.