Compared with real-valued complex networks, complex-valued dynamic networks have a wider application space. In addition, considering the existence of time delay and uncertainty in the actual system, the synchronization problem of fractional-order complex-valued dynamic networks with uncertain parameter and coupled delay is studied in this paper. In particular, the uncertain parameter is correlated with time delay. By using fractional derivative inequalities and linear delay fractional order equations, the synchronization of uncertainty complex networks with coupling delay is realized. Sufficient conditions for global asymptotic synchronization are obtained. The obtained synchronization results are applicable to most complex network systems with or without delay. Finally, numerical simulations verify the effectiveness of the obtained results.
By utilizing a natural mercury lamp, the transverse Zeeman background correction method, which is used for trace mercury measurement in air, is studied. In this paper, a natural mercury lamp is used as a light source, and is placed in a 1.78-T magnetic field. The lamp emits two linearly polarized light beams σ± and π of 253.65-nm resonance line, which are used as bias light and absorbing light, respectively. A polarization modulation system is used to allow σ± and π light beams to pass through alternately with a certain frequency. A multipath optical cell with 12-m optical path is used to increase optical distance. Based on the system described above, the influence caused by UV absorbing gases, such as NO2, SO2, acetone, benzene, and O3, is analyzed. The results show that it may reduce the detection limit when the concentrations of these gases exceed 83.4 ppm, 20.3 ppm, 142.3 ppm, 0.85 ppm, and 0.55 ppm, respectively. The detection limit of the system is calculated and can achieve up to 1.44 ng/m3 in 10 minutes. Measurements on mercury sample gas and air are carded out, and the measured data are compared with the data of RA-915 mercury analyzer (Russia). The result shows that the correlation coefficient reaches up to 0.967. The experimental results indicate that the transverse Zeeman background correction method can be used to quantify trace mercury in air with high-precision. 相似文献
Dark sector may couple to the Standard Model via one or more mediator particles.We discuss two types of mediators:the dark photon A’and the dark scalar mediatorΦ.The total cross-sections and various differential distributions of the processes e+e-→qqA’and e+e→qqφ(q=u,d,c,s and b quarks)are discussed.We focus on the study of the invisible due to the cleaner background at future e+e-colliders.It is found that the kinematic distributions of the two-jet system could be used to identify(or exclude)the dark photon and the dark scalar mediator,as well as to distinguish between them.We further study the possibility of a search for dark photons at a future CEPC experiment with s1/2=91.2 GeV and 240 GeV.With CEPC running at s1/2=91.2 GeV,it would be possible to perform a decisive measurement of the dark photon(20 GeV相似文献
We address the quantum transition of a spin-1/2 antiferromagnetic Kondo lattice model with an easy-axis anisotropy using the extended dynamical mean field theory. We derive results in real frequency by using the bosonic numerical renormalization group (BNRG) method and compare them with quantum Monte Carlo results in Matsubara frequency. The BNRG results show a logarithmic divergence in the critical local spin susceptibility, signaling a destruction of Kondo screening. The T=0 transition is consistent with being second order. The BNRG results also display some subtle features; we identify their origin and suggest means for further microscopic studies. 相似文献