In this article, photosensitive polyimides (PSPIs) with photosensitive groups, o-nitrobenzyl ether groups (Nb), were successfully synthesized based on 2,2′-dihydroxy benzophenone-3,3′,4,4′-tetracarboxylic dianhydride and on diamine containing ethylene glycol chains (ODA). Also, a series of polyimide (PI), ODA-1-PI, ODA-3-PI, and ODA-5-PI with a number of ethylene glycol chains of 1, 3, and 5 were prepared to investigate the relationship between structure and solubility. Interestingly, ODA-5-PI, which possesses a large number of ethylene glycols, exhibited the most excellent solubility. Therefore, due to the good solubility of ODA-5-PI in organic solvents and alkaline solutions, a PSPI, poly(1,4-phenyleneoxy-3,6,9,12,15-pentaoxaoctane-1,4-phenylene-2,2′-di[2-nitrobenzyloxy]benzophenone-3,3′,4,4′-tetracarboxdiimide), named ODA-5-PSPI, was synthesized by linking Nb, which is a photosensitive group. Aiming at producing positive tone patterns, the synthesized ODA-5-PSPI was exposed to UV irradiation and then to a post-exposure bake. Afterward, it was developed using a 2.38 wt% tetramethylammonium hydroxide solution. Furthermore, a photoacid generator (PAG) was additionally incorporated for a micropatterning process. Notably, in the presence of the PAG, the photocleavage of ODA-5-PSPI occurred not only by the intramolecular rearrangement of Nb but also by its hydrolysis reaction. As a result, due to the synergistic effect of photocleavage, the micropatterning of ODA-5-PSPI with PAG could be clearly obtained with less energy (2.0 J/cm2) compared with that without PAG (3.6 J/cm2). Therefore, through the addition of PAG, the photosensitivity was improved by 45%. 相似文献
Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3 T. The proposed sequence rapidly acquires a time series of T1ρ maps with 4.0 second temporal resolution and 10 slices of volumetric coverage. Simulation, phantom, and in vivo experiments are used to evaluate many aspects of the sequence and its implementation including fidelity of measured T1ρ dynamics, potential confounds to the T1ρ response, imaging parameter tradeoffs, time series analysis approaches, and differences compared to blood oxygen level dependent functional magnetic resonance imaging. It is shown that the high temporal resolution and volumetric coverage of the sequence are obtained with some expense including underestimation of the T1ρ response, sensitivity to T1 dynamics, and reduced signal-to-noise ratio. In vivo studies using a flashing checkerboard functional magnetic resonance imaging paradigm suggest differences between T1ρ and blood oxygen level dependent activation patterns. Possible sources of the functional T1ρ response and potential sequence improvements are discussed. The capability of T1ρ to map whole-brain pH and metabolism dynamics with high temporal and spatial resolution is potentially unique and warrants further investigation and development. 相似文献
The CD spectroscopy of a chiral compound in solution yields an average CD value derived from all of the conformations of a chiral molecule. By contrast, CD spectroscopy of cold chiral molecules in the gas phase distinguishes specific conformers of a chiral molecule, but the weak CD effect has limited the practical application of this technique. Reported herein is the first resonant two‐photon ionization CD spectra of ephedrines in a supersonic jet using circularly polarized laser pulses, which were generated by synchronizing the oscillation of the photoelastic modulator with the laser firing. The spectra exhibited well‐resolved CD bands which were specific for the conformations and vibrational modes of each enantiomer. The CD signs and magnitudes of the jet‐cooled chiral molecules were very sensitive to their conformations and thus offered crucial information for determining the three‐dimensional structures of chiral species, as conducted in combination with quantum chemical calculations. 相似文献
We propose a light shutter device using dye-doped cholesteric liquid crystals for a high-visibility see-through display. In the focal-conic state, the proposed device can perfectly block the background image through simultaneous use of light scattering and absorption effects in a single-layered structure. By switching the proposed device placed at the backside of a see-through display, we can choose transparent or high-visibility display modes in a see-through display. 相似文献
A neutral Dirac fermion ψ with a nonzero magnetic dipole moment is supplied as a singlet within the context of the standard model and is considered as a dark matter candidate near the electroweak scale (10–1000 GeV). We discuss its dynamics with the ordinary matters through the magnetic dipole moment. The magnetic dipole moment constrained by the relic abundance may be as large as 10−18–10−17e⋅cm. We show that the elastic scattering is due to a spin–spin interaction for the direct detections and the predictions are under experimental exclusion limits of the current direct detectors, XENON10 and CDMS II, and consider the possibility of dark matter detection in the future. 相似文献
This template will self‐destruct : A unique particle‐growth mechanism involves growth of new coordination polymers on the surface of initially formed hexagonal blocks and concomitant dissolution of the blocks to form hexagonal tubes (see scheme and scanning electron, optical, and fluorescence microscopy images). Calcination of the tubes yields ZnO particles of the same shape.
A method for the use of persistent homology in the statistical analysis of landmark-based shape data is given. Three-dimensional landmark configurations are used as input for separate filtrations, persistent homology is performed, and persistence diagrams are obtained. Groups of configurations are compared using distances between persistence diagrams combined with dimensionality reduction methods. A three-dimensional landmark-based data set is used from a longitudinal orthodontic study, and the persistent homology method is able to distinguish clinically relevant treatment effects. Comparisons are made with the traditional landmark-based statistical shape analysis methods of Dryden and Mardia, and Euclidean Distance Matrix Analysis. 相似文献
This study was undertaken to assess the relative bias between two types of sampling methods for volatile organic compounds (VOCs), i.e., sorbent tube vs. bag sampling methods and between different standard phases. For the purpose of this comparative study, gaseous standards containing three major aromatic VOCs (benzene, toluene, and xylene—commonly called BTX) were analyzed by thermo-desorption gas chromatography (TD-GC) with flame ionization detector. According to our findings, the relative response of target compounds can be smaller in the bag method than in the tube method. Although the relative bias varies with the sample transfer conditions for the TD, the mean slope values of the former are smaller by up to 20% relative to the latter, possibly due to sorptive loss on the bag sampler. In addition, the effects of different standard matrices (i.e. liquid and gas phases) were also examined using the sorbent tube method. The results indicated that the slope values of the gas-phase standard were smaller by half (about 43–56%) than the liquid-phase standard. Consequently, information concerning the extent of relative bias between sampling methods (e.g., bag and tube) or standard matrices (e.g., gas and liquid) should be considered as one of the key factors in TD applications. 相似文献