排序方式: 共有107条查询结果,搜索用时 46 毫秒
41.
A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL).The ion source has been optimized to be operated at 28GHz for its maximum performance.The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping.For 28GHz operation,the magnet assembly can produce peak mirror fields on axis 3.6T at injection,2.2T at extraction and a radial sextupole field of 2.0T at plasma chamber wall.A unique feature of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. During the ongoing commissioning phase at 18GHz with a stainless steel chamber,tests with various gases and some metals have been conducted with microwave power less than 3.2kW and it turned out the performance is very promising.Some record ion beam intensities have been produced,for instance,810eμA of O~(7 ),505eμA of Xe~(20 ),306eμA of Xe~(27 ),21eμA of Xe~(34 ),2.4eμA of Xe~(38 ) and so on.To reach better results for highly charged ion beams,further modifications such as an aluminium chamber with better cooling,higher microwave power and a movable extraction system will be done,and also emittance measurements are being prepared. 相似文献
42.
43.
44.
45.
针对舰船装备软件接口交互信息量大,利用现有动态测试技术对此类软件开展测试工作时效率较低,自动化测试水平亟待提高的现状,归纳分析了舰船装备软件测试系统的主要能力需求,研究了接口协议形式化、测试用例自动生成、测试用例自动驱动、通信接口转换等关键技术,并以上述技术为基础给出了舰船装备软件测试系统的体系架构设计方案,进而实现了一种基于LoadRunner自动化应用程序接口(LoadRunner Automation API)的舰船装备软件测试系统,为舰船装备软件提供了一种可行的自动化测试手段;该测试系统主要包括测试管理模块、测试用例生成模块、测试用例驱动模块和数据收集与分析模块;采用该测试系统能够有效提高舰船装备软件的测试效率。 相似文献
46.
一种改进的同步辐射X射线荧光原位分析人肝细胞胞质溶胶内金属蛋白分布的方法 总被引:1,自引:0,他引:1
对同步辐射X射线荧光分析技术(SBXRF)原位测定蛋白质经十二烷基硫酸铀.聚丙烯酰胺凝胶电泳(SDS-PAGE)分离后条带中微量元素的方法做了重要改进。通过增加一个于胶步骤,使得本底材料对光源的康普顿散射明显减弱,本底信号降低到约为湿胶的10%,从而可以用来测定蛋白条带内比锌轻的微量元素的相对含量。所提出的方法有望成为一种具有广泛应用前景的生物样品中微量元素的种态分析方法。对人肝细胞胞质溶胶内金属蛋白分布的研究结果表明:在15-95kDa的范围内有6个含锌蛋白,相对分子量分别为17.5、20.5、27、35、55及63kDa,其中63kDa蛋白为主要的含锌蛋白;此外至少还有4种分子量分别为20、23、43和83.5kDa的含铁蛋白分布于这个分子量范围内。 相似文献
47.
利用双晶单色器和精密二圆衍射仪,在北京同步辐射装置建立了同步辐射X射线驻波实验技术,并用这一实验技术结合X射线衍射方法,研究了Si晶体中外延生长的起薄Ge原于层的微结构。实验结果表明,由于Ge原予的偏析,在Si晶体样品中形成了共格生长的GexSi1-x合金层,浓度平均值为x≈0.13;650℃退大会使Ge原予向表面扩散,Si晶体中的合金层消失,在晶体表面形成接近纯Ge的单原于层。 相似文献
48.
50.
Self-biased magnetoelectric responses in magnetostrictive/piezoelectric composites with different high-permeability alloys
下载免费PDF全文
![点击此处可从《中国物理 B》网站下载免费的PDF全文](/ch/ext_images/free.gif)
We comparatively investigate the influence of various high-permeability alloys on the hysteretic and remanent res- onant magnetoelectric (ME) response in a composite of magnetostrictive nickel (Ni) and piezoelectric Pb(Zrl_x, Tix)O3 (PZT). In order to implement this comparative research, Co-based amorphous alloy (CoSiB), Fe-based nanocrystalline alloy (FeCuNbSiB) and Fe-based amorphous alloy (FeSiB) are used according to different magnetostriction (2s) and saturation magnetization (μtoMs) characteristics. The bending and longitudinal resonant ME voltage coefficients (αME,b and αME,1) are observed comparatively for CoSiB/Ni/PZT, FeCuNbSiB/Ni/PZT, and FeSiB/Ni/PZT composites. The experimental data indicate that the FeSiB/Ni/PZT composite has the largest remanent self-biased aME,b and aME,1 due to the largest magnetic grading of λs and μ0Ms in the FeSiB/Ni layer. When the number of FeSiB foils is four, the maximum remanent aME,b and aME,I at zero bias magnetic field are 57.8 V/cm·Oe and 107.6 V/cm·Oe, respectively. It is recommended that the high-permeability alloy is supposed to have larger λs and μ0Ms for obtaining a larger remanent self-biased ME responses in ME composite with high-permeability alloy. 相似文献