全文获取类型
收费全文 | 116篇 |
免费 | 43篇 |
国内免费 | 44篇 |
专业分类
化学 | 58篇 |
晶体学 | 7篇 |
力学 | 11篇 |
综合类 | 5篇 |
数学 | 9篇 |
物理学 | 113篇 |
出版年
2024年 | 7篇 |
2023年 | 11篇 |
2022年 | 8篇 |
2021年 | 13篇 |
2020年 | 7篇 |
2019年 | 9篇 |
2018年 | 12篇 |
2017年 | 16篇 |
2016年 | 14篇 |
2015年 | 10篇 |
2014年 | 19篇 |
2013年 | 9篇 |
2012年 | 10篇 |
2011年 | 6篇 |
2010年 | 10篇 |
2009年 | 6篇 |
2008年 | 9篇 |
2007年 | 5篇 |
2006年 | 3篇 |
2005年 | 5篇 |
2004年 | 4篇 |
2003年 | 3篇 |
2002年 | 1篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1998年 | 3篇 |
1989年 | 1篇 |
排序方式: 共有203条查询结果,搜索用时 15 毫秒
121.
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure, performance test and results of the quadrant silicon detector developed recently at the China Institute of Atomic Energy are presented. The detector is about 300 μm thick with a 48 mm×48 mm active area. The leakage current under the full depletion bias voltage of -16 V is about 2.5 nA, and the rise time is better than 160 ns. The energy resolution for a 5.157 MeV α-particle is around the level of 1%. Charge sharing effects between the neighboring quads, leading to complicated correlations between two quads, were observed when α particles illuminated on the junction side. It is explained as a result of distortion of the electric field of the inter-quad region. Such an event is only about 0.6% of all events and can be neglected in an actual application. 相似文献
122.
利用高非线性光纤产生量子关联光子对的实验研究 总被引:2,自引:2,他引:0
光纤中基于三阶(克尔)非线性效应的自发四波混频是制备量子关联光子对的有效方法之一。若采用商售高非线性光纤作为产生光子对的非线性介质,则有利于减小所需光纤的长度,从而缩小实验装置体积并降低对于抽运源的要求。利用脉冲光抽运20m的高非线性光纤产生通讯波段的频率近简并关联光子对,研究了光纤的弱双折射特性对于光子对产生的影响。当抽运光沿高非线性光纤的偏振轴入射时,具有最大的光子对产生效率,且光子对绝大部分与抽运光偏振平行;抽运光沿与光纤偏振轴45°入射时,光子对的产生效率最小,约为最大值的80%。 相似文献
123.
针对供应商和零售商组成的农产品供应链,研究市场需求受到努力水平影响的农产品供应链协调问题.由于双重边际效应,分散式供应链中的最优生产数量低于集中式供应链的情况,零售商努力水平也相对较低.引入期权契约时,在零售商主导期权契约的供应链中,研究得到零售商的最优初始订货量和最优期权价格,以及供应商的最优生产数量,实现供应链协调.数值分析证实了期权契约有助于提高零售商的努力水平以及整个供应链的利润. 相似文献
124.
为了实现空间中一定距离的近似等光程光束传输,设计了一种包含离轴椭球面反射镜的波面整形系统。基于几何光学与初级像差理论,结合Zemax光学设计软件,分析了椭球面反射镜圆锥系数、离轴量对像面处光程差的影响;设计了平面-椭球面反射镜和双椭球面反射镜2种光学结构的波面整形系统,并比较了2种结构的公差。分析结果表明:平面-椭球面反射系统和双椭球面反射系统均实现了空间中1 m距离的光束传输,且2种结构系统在3 mm物高视场和孔径角为6°条件下,各视场光瞳之间的光程差分别为0.14 mm和0.04 mm,因此,双椭球面反射结构整形效果优于平面-椭球面反射系统,但双椭球面反射结构对公差的敏感度更高。 相似文献
125.
示差折光检测-固相萃取和高效液相色谱法测定水果中的糖 总被引:3,自引:0,他引:3
研究了高效液相色谱法测定水果中的糖。水果样品的糖提取液用 Waters Sep- Pak- C18固相萃取小柱预分离 ,以 Waters Sugar- Pak- 1钙型阳离子交换柱为固定相 ,0 .0 5 g· L-1EDTA钙钠水溶液为流动相分离 ,示差折光仪为检测器检测。蔗糖、葡萄糖和果糖的检出限分别为 2 mg/ L、4 mg/ L和 4 mg/ L,RSD在0 .76 %— 1.8%之间 ,标准回收率在 97%— 10 3%之间。本方法用于几种水果样品的测定 ,结果令人满意。 相似文献
126.
Study on the novel neutron-to-proton convertor for improving the detection efficiency of a triple GEM based fast neutron detector 总被引:1,自引:0,他引:1
A high-efficiency fast neutron detector prototype based on a triple Gas Electron Multiplier(GEM) detector, which, coupled with a novel multi-layered high-density polyethylene(HDPE) as a neutron-to-proton converter for improving the neutron detection efficiency, is introduced and tested with the Am-Be neutron source in the Institute of Modern Physics(IMP) at Lanzhou in the present work. First, the developed triple GEM detector is tested by measuring its effective gain and energy resolution with55 Fe X-ray source to ensure that it has a good performance.The effective gain and obtained energy resolution is 5.0×104and around 19.2%, respectively. Secondly, the novel multi-layered HDPE converter is coupled with the cathode of the triple GEM detector making it a high-efficiency fast neutron detector. Its effective neutron response is four times higher than that of the traditional single-layered conversion technique when the converter layer number is 38. 相似文献
127.
A novel simple method based on pulse area analysis (PAA) is presented for acquisition of nuclear spectra by a digitizer. The PAA method can be used as a substitute for the traditional method of pulse height analysis (PHA). In the PAA method a commercial digitizer was employed to sample and sum in the pulse, and the area of the pulse is proportional to the energy of the detected radiation. The results of simulation and experiment indicate the great advantages of the PAA method, especially as the count rate is high and the shaping time constant is small. When the shaping time constant is 0.5 μs, the energy resolution of PAA is about 66% better than that of PHA. 相似文献
128.
Spallation neutrons were produced by the irradiation of Pb with 250 MeV protons. The Pb target was surrounded by water which was used to slow down the emitted neutrons. The moderated neutrons in the water bath were measured by using the resonance detectors of Au, Mn and In with a cadmium (Cd) cover. According to the measured activities of the foils, the neutron flux at different resonance energies were deduced and the epithermal neutron spectra were proposed. Corresponding results calculated with the Monte Carlo code MCNPX were compared with the experimental data to check the validity of the code. The comparison showed that the simulation could give a good prediction for the neutron spectra above 50 eV, while the finite thickness of the foils greatly effected the experimental data in low energy. It was also found that the resonance detectors themselves had great impact on the simulated energy spectra. 相似文献
129.
Nonionizing energy loss (NIEL) has been applied to a number of studies concerning displacement damage effects in materials and devices. However, most studies consider only the contribution of displacement damage effects, neglecting the contribution from phonons. In this paper, a NIEL model, which considers the contribution of phonons, has been established using the Monte Carlo code SRIM. The maximum endurable fluence for silicon detectors has been estimated using the equivalent irradiation fluence compared with experimental data for the incident particles. NIEL is proportional to the equivalent irradiation fluence that the detector has received. 相似文献
130.