首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   166篇
  免费   9篇
化学   162篇
力学   2篇
数学   5篇
物理学   6篇
  2023年   2篇
  2021年   2篇
  2020年   5篇
  2019年   6篇
  2018年   8篇
  2017年   6篇
  2016年   11篇
  2015年   10篇
  2014年   11篇
  2013年   14篇
  2012年   23篇
  2011年   19篇
  2010年   10篇
  2009年   10篇
  2008年   4篇
  2007年   6篇
  2006年   6篇
  2005年   4篇
  2004年   8篇
  2003年   2篇
  2002年   4篇
  1996年   1篇
  1994年   1篇
  1992年   1篇
  1987年   1篇
排序方式: 共有175条查询结果,搜索用时 31 毫秒
81.
A new on-line cloud point extraction (CPE) system coupled to ICP-OES was designed for simultaneous extraction, preconcentration and determination of Cd2+, Co2+, Cr3+, Cu2+, Fe3+ and Mn2+ ions in water samples. This is based on the complexation of the metal ions with 1-(2-thenoyl)-3,3,3-trifluoraceton reagent (TTA) at pH 6.0 in the presence of non-ionic surfactant of Triton X-114. The micellar solution was heated above 60 °C and loaded through a column packed with cotton, which acts as a filter for retaining the analyte-entrapped surfactant-rich phase. Then the surfactant-rich phase was eluted using propanol:0.5 mol L−1 nitric acid solution (75:25, v/v) at a flow rate of 3.0 mL min−1 and directly introduced into the nebulizer of the ICP-OES. Several factors influencing the instrumental conditions and extraction were evaluated and optimized. Under the optimum conditions, the enhancement factors of the proposed method for target ions were between 42 and 97, the detection limits (DLs) were in the range of 0.1-2.2 μg L−1. The relative standard deviations (R.S.D.s) at 100 μg L−1 concentration levels of each ion were found to be less than 4.6%. Also, the calibration graphs were linear in the range of 0.5-100 μg L−1 with the correlation coefficients within the range of 0.9948-0.9994.Finally, the developed method was successfully applied to the extraction and determination of the mentioned metal ions in the tap, well, sea and mineral water samples and satisfactory results were obtained.  相似文献   
82.
In the present work, a on-chip electromembrane extraction (CEME) was designed and employed for simultaneous extraction of mefenamic acid (MEF) and diclofenac (DIC), as acidic model analytes, and betaxolol (BET), as a basic model analyte, followed by HPLC-UV. The CEME consists of two polymethyl methacrylate (PMMA) parts which each part consists of two separated microfluidic channels. A polypropylene sheet membrane impregnated with an organic solvent was sandwiched between the parts. One of the parts was used as the flow path for the sample solution and the other one as holder for the acceptor phases. The separated microfluidic channels of the sample solution part were connected to each other using a small piece of a capillary tube and the sample solution was pumped through them by means of a micro-syringe pump. However, the acceptor phases of the acidic and basic analytes were separately kept stagnant in the two microfluidic channels during the extraction process. A d.c. potential was applied for migration of the analytes from sample solution through the organic membrane into the acceptor phases. All effective variables on the extraction efficiency of the analytes were optimized. Under the optimized conditions, preconcentration factors higher than 15 were achieved and the calibration curves were linear in the range of 10–500 μg L−1 (r2 > 0.9982). RSD% values (n = 4) and LODs were less than 7.1% and 5.0 μg L−1. The results demonstrated that CEME could efficiently be used for the simultaneous analysis of acidic and basic analytes in biological samples.  相似文献   
83.
A rapid and simple microextraction method with a high sample clean-up, termed as tandem air-agitated liquid–liquid microextraction (TAALLME), is described. This method is based upon the tandem implementation of the air-agitated liquid–liquid microextraction (AALLME), and this approach improves the applicability of the dispersive liquid–liquid microextraction (DLLME) methods in complicated matrices. With very simple tools, the three non-steroidal anti-inflammatory drugs diclofenac, ibuprofen, and mefenamic acid were efficiently extracted, with an overall extraction time of 7 min. By performing the first AALLME, these acidic analytes, contained in an aqueous sample solution (donor phase, 8.0 mL), were extracted into the organic solvent (1,2-dichloroethane, 37 μL), and their simple back-extraction into the aqueous acceptor solution (pH, 10.01, 51 μL) was obtained in 2 min by a second implementation of AALLME. Response surface methodology (RSM) was used for optimization of the experimental parameters. The pH values 2.94 and 10.01 were obtained for the donor and acceptor phases, respectively, and the volumes 99.5 and 51 μL were obtained for the organic solvent and the acceptor phase, respectively, as the optimal extraction conditions. Under the optimized conditions, tandem AALLME-HPLC-UV provided a good linearity in the range of 0.5–4000 ng mL−1, limits of detection (0.1–0.3 ng mL−1), extraction repeatabilities (relative standard deviations (RSDs) below 7.7%, n = 5), and the enrichment factors (EFs) of 80–104. Finally, the applicability of the proposed method was evaluated by the extraction and determination of the drugs under study in the wastewater and human plasma samples.  相似文献   
84.
85.
86.
In this study, a fast, simple and efficient ultrasound-assisted emulsification microextraction (USAEME) method was successfully developed based on applying low density organic solvents. Fourteen microliters of toluene was injected slowly into a 12 mL home-designed centrifuge glass vial containing an aqueous sample that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and 2 μL of separated toluene (about 4 μL) was injected into a gas chromatographic system equipped with a flame ionization detector (GC-FID) for analysis. Some polycyclic aromatic hydrocarbons (PAHs) were selected as model compounds for developing the method and evaluating its performance and to compare the efficiency of the proposed method with previously reported techniques. Several factors influencing the emulsification, extraction and collection efficiency such as the nature and volume of organic solvent, emulsification–extraction temperature, ionic strength and equilibrium and centrifugation times were investigated and optimized. Under the optimum conditions, preconcentration factors (PFs) in a range of 1776–2714 were obtained. The performance of the proposed method was studied in terms of linear dynamic range (LDRs from 0.05 to 100 μg L−1), linearity (R2 ≥ 0.994), precision (repeatability: RSD% ≤ 7.9, reproducibility: RSD% ≤ 14.6) and extraction percents (59.2–90.5%). Limits of detection (LODs) in the range of 0.02–0.05 μg L−1 were obtained for different PAHs. The applicability of the proposed method was evaluated by the extraction and determination of PAHs from several natural water samples.  相似文献   
87.
An emulsification liquid phase microextraction followed by on-line phase separation coupled to high performance liquid chromatography (HPLC) is introduced based on a novel idea for the separation of dispersed organic phase from aqueous phase. In this method, the dispersed organic extraction phase was filtered using an in-line filter and it was separated from the water sample. The new approach is simple and, in addition to improving some limitations of the conventional emulsification liquid phase microextraction, eliminates the need for centrifugation in the phase separation step.  相似文献   
88.
We have combined dynamic hollow fiber liquid-phase microextraction with GC and electron capture detection for the quantitative determination of five chlorobenzenes in water samples. Extraction is based on an automated dynamic extraction device called TT-tube extractor which consists of a polypropylene hollow fiber mounted inside a stainless steel tube. Toluene is used as the extraction solvent that fills the lumen and pores of the hydrophobic fiber and flows through the lumen of the fiber using a programmable syringe pump. The type of organic solvent, ionic strength, diameter of the TT-tube, sample volume, and the times for extraction and dwelling were optimized. Under optimum conditions, the method gives limits of detection as low as 10–100?ng?L?1, a linear dynamic range of 0.05–100?μg?L?1, and relative standard deviations of <7% (n?=?6). The preconcentration factor can be as large as 562–973. In an example for a practical application, the chlorobenzenes were successfully determined in environmental aqueous samples. The hollow fiber membrane can be used at least 20 times without any carry-over or loss in extraction efficiency. The system is inexpensive and convenient, and requires minimal manual handling.
Figure
Dynamic hollow fiber liquid phase microextraction apparatus  相似文献   
89.
We describe a method for ionic liquid based dispersive liquid-liquid microextraction of Co(II), Cu(II), Mn(II), Ni(II) and Zn(II), followed by their determination via flow injection inductively coupled plasma optical emission spectrometry. The method is making use of the complexing agent 1-(2-thenoyl)-3,3,3-trifluoracetone, the ionic liquid 1-hexyl-3-methyl imidazolium bis(trifluoromethylsulfonyl)imide, and of ethanol as the dispersing solvent. After extraction and preconcentration, the sedimented ionic liquid (containing the target analytes) is collected, diluted with 1-propanol, and introduced to the ICP-OES. Effects of pH, ionic strength, ligand to metal molar ratio, volumes of extraction and disperser solvents on the performance of the microextraction were optimized in a half-fractional factorial design. The significant parameters were optimized using a face-centered central composite design. The method has detection limits between 0.10 and 0.20?ng?mL?1 of the metal ions, preconcentration factors between 79 and 102, linear responses in 0.25 to 200?ng?mL?1 concentration ranges, and relative standard deviations of 3.4 to 6.0%. The method was successfully applied to the analysis of drinking water, a fish farming pond water, and waste water from an industrial complex.
Figure
Ionic liquid based dispersive liquid-liquid microextraction of Co, Cu, Mn, Ni and Zn followed by determination via flow injection inductively coupled plasma optical emission spectrometry  相似文献   
90.
A simple, rapid and efficient dispersive liquid–liquid microextraction based on the solidification of floating organic drop (DLLME–SFO) method, followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed for the simultaneous preconcentration and determination of heavy metals in water samples. One variable at a time method was applied to select the type of extraction and disperser solvents. Then, an orthogonal array design (OAD) with OA16 (45) matrix was employed to study the effects of different parameters on the extraction efficiency. Under the best experimental conditions (extraction solvent: 140 μL of 1-undecanol; disperser solvent: 2.0 mL of acetone; ligand to metal mole ratio: 20; pH: 6 and without salt addition), the enhancement factor ranged from 57 to 96. The calibration graphs were linear in the range of 0.5–250 μg L−1 for Mn, 1.25–250 μg L−1 for Cr, Co and Cu with correlation coefficient (r) better than 0.990. The detection limits were between 0.1 and 0.3 μg L−1. Finally, the developed method was successfully applied to extraction and determination of the mentioned metal ions in the tap, sea and mineral water samples and satisfactory results were obtained.  相似文献   
[首页] « 上一页 [4] [5] [6] [7] [8] 9 [10] [11] [12] [13] [14] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号