首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   3篇
  国内免费   2篇
化学   94篇
力学   3篇
数学   4篇
物理学   22篇
  2023年   1篇
  2022年   3篇
  2021年   3篇
  2020年   4篇
  2019年   6篇
  2018年   5篇
  2017年   3篇
  2016年   5篇
  2015年   5篇
  2014年   8篇
  2013年   10篇
  2012年   7篇
  2011年   17篇
  2010年   12篇
  2009年   5篇
  2008年   6篇
  2007年   4篇
  2006年   2篇
  2005年   1篇
  2003年   4篇
  2000年   1篇
  1998年   1篇
  1996年   6篇
  1995年   1篇
  1992年   1篇
  1986年   1篇
  1984年   1篇
排序方式: 共有123条查询结果,搜索用时 11 毫秒
31.
A selective separation and preconcentration method for the determination of gold ions in water and ore samples has been developed using dispersive liquid–liquid microextraction, followed by flame atomic absorption spectrometry. 4-Ethyl-1(2-(4-(4-nitrophenyl)piperazin-1-yl)acetyl)thiosemicarbazide) (NPPTSC) has been used for the first time as new chelating reagent. A mixture of ethanol (dispersive solvent) and carbon tetrachloride (extraction solvent) was used. Some parameters affecting the extraction procedure including the type and volume of the extracting and dispersive solvents, HNO3 concentration, the chelating agent amount, volume of sample, and foreign ions have optimized. Also, the complex formation between gold ions and the ligand has been investigated in a methanol–water solution (1:1) using UV–visible spectrometry. The spectrophotometric titration data showed that of Au–NPPTSC complex composition was found to be 3:2. After optimizing the instrumental and experimental parameters, we achieved a detection limit of 1.5 µg L?1, a preconcentration factor of 50, and a linear dynamic range of 10.0–400.0 µg L?1. The relative standard deviation obtained 2.1% at 50 µg L?1 for gold ions (n = 10). The proposed method was successfully performed for the determination of gold in certified reference material, environmental water, and ore samples.  相似文献   
32.
We report the development of 4D scanning transmission ultrafast electron microscopy (ST-UEM). The method was demonstrated in the imaging of silver nanowires and gold nanoparticles. For the wire, the mechanical motion and shape morphological dynamics were imaged, and from the images we obtained the resonance frequency and the dephasing time of the motion. Moreover, we demonstrate here the simultaneous acquisition of dark-field images and electron energy loss spectra from a single gold nanoparticle, which is not possible with conventional methods. The local probing capabilities of ST-UEM open new avenues for probing dynamic processes, from single isolated to embedded nanostructures, without being affected by the heterogeneous processes of ensemble-averaged dynamics. Such methodology promises to have wide-ranging applications in materials science and in single-particle biological imaging.  相似文献   
33.
γ-Fe2O3 (maghemite)-silica nanocomposite particles were synthesized using a sol-gel method. The condensation products of 3-glycidoxy propyltrimethoxy silane (GPTMS) and nitrilotriacetic acid (NTA) were introduced onto the surfaces of the γ-Fe2O3-silica nanocomposite particles and subsequently, these modified surfaces were complexed with cobalt (Co+2) metal ions. A possibility of using these surface modified γ-Fe2O3-silica particles for the purification of 6×histidine tagged recombinant benzaldehyde lyase (BAL, EC 4.1.2.38) based on magnetic separation was investigated. X-ray diffraction (XRD), thermal analysis, and vibrating sample magnetometry (VSM) methods were used to characterize the surface modified superparamagnetic γ-Fe2O3 (maghemite)-silica nanoparticles. XRD (Scherer's equation) results indicate that the primary particle size of maghemite was around 11 nm. Magnetic characterization results confirmed that the γ-Fe2O3 (maghemite)-silica nanoparticles were superparamagnetic. According to sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) results, these superparamagnetic nanoparticles specifically capture 6×His-tagged BAL from crude extract of Escherichia coli (E. coli) BL21(DE3)pLysS/BALHIS. This study shows that the surface modified γ-Fe2O3 (maghemite)-silica nanoparticles are eligible for immobilized metal-ion affinity adsorption for histidine tagged recombinant proteins with its high capacity (3.16±0.4 mg/g) and selectivity.  相似文献   
34.
Cloud-point extraction (CPE) using the non-ionic surfactant Triton X-100 was used successfully to remove a highly toxic dye, rhodamine 6G (R6G), from water and wastewater. The effects of different analytical parameters such as pH, concentration of Triton X-100 (TX-100) and salts, equilibrium temperature, and incubation time on the efficiency of the extraction of R6G were studied in detail, and optimum conditions for dye extraction were obtained. Thermodynamic parameters including changes in Gibbs free energy, enthalpy, and entropy were also calculated, and these parameters indicated that the CPE of R6G was feasible, spontaneous, and endothermic in the temperature range of 75-95 degrees C. The equilibrium solubilization capacity of TX-100 was found to be 1.10 mmol/mol by using Langmuir isotherm models. No significant interference effects were observed in the presence of phenol and its derivatives, some acidic and basic dyes and most of the anions and cations. It was concluded that the CPE process described in this paper can be an alternative technique for removal of dyes and other pollutants from waters and wastewaters.  相似文献   
35.
A method for speciation of Cr(III) and Cr(VI) in real samples has been developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its pyrrolidinedithiocarbamate (APDC) complex by using a column containing Amberlite XAD–2000 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of pH, flow‐rate, adsorption and batch capacity and effect of various metal cations and salt anions on the sorption onto the resin were investigated. The adsorption is quantitative in the pH range of 1.5–2.5, and Cr(VI) ion was desorbed by using H2SO4 in acetone. The recovery of Cr(VI) was 97 ± 4 at a 95% confidence level. The highest preconcentration factor was 80 for a 200 mL sample volume. The adsorption and batch capacity of sorbent were 7.4 and 8.0 mg g?1 Cr(VI), respectively, and loading half time was 5.0 min. The detection limit of Cr(VI) is 0.6 μg/L. The procedure has been applied to the determination and speciation of chromium in stream water, tap water, mineral spring water and spring water. Also, the proposed method was applied to total chromium preconcentration in microwave digested moss and rock samples with satisfactory results. The developed method was validated with CRM‐TMDW‐500 (Certified Reference Material Trace Metals in Drinking Water) and BCR‐CRM 144R s (Certified Reference Material Sewage Sludge, Domestic Origin) and the results obtained were in good agreement with the certified values. The relative standard deviations were below 6%.  相似文献   
36.
37.
AWRK6 was a synthesized peptide developed based on the natural occurring peptide dybowskin-2CDYa, which was discovered in frog skin in our previous study. Here, a quantitative determination method for AWRK6 analysis in rat plasma by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established and validated following U.S. FDA guidelines. A combination of plasma precipitation and liquid–liquid extraction was applied for the extraction. For pharmacokinetics study, the rats were administrated with AWRK6 via intraperitoneal and intravenous injection. The prepared plasma samples were separated on an ODS column and analyzed by tandem MS using precursor-to-product ion pairs of m/z: 533.4→84.2 for AWRK6 and m/z: 401.9→101.1 for internal standard Polymyxin B sulfate in multiple reaction monitoring mode. AWRK6 concentrations in rat plasma peaked at about 1.2 h after intraperitoneal injections at 2.35, 4.7 and 9.4 mg/kg bodyweight. The terminal half-life was around 2.8 h. The absolute bioavailability of AWRK6 was 50% after 3 doses via injection, and the apparent volume of distribution was 4.884 ± 1.736 L. The obtained determination method and pharmacokinetics profiles of AWRK6 provides a basis for further development, and forms a benchmark reference for peptide quantification.  相似文献   
38.
39.
Kaya M  Volkan M 《Talanta》2011,84(1):122-126
A new chloride generation system was designed for the direct, sensitive, rapid and accurate determination of the total germanium in complex matrices. It was aimed to improve the detection limit of chloride generation technique by increasing the vapor pressure of germanium tetrachloride (GeCl4). In order to do so, a novel joint vapor production and gas-liquid separation unit equipped with a home-made oven was incorporated to an ordinary nitrous oxide-acetylene flame atomic absorption spectrometer. Several variables such as reaction time, temperature and acid concentration have been investigated. The linear range for germanium determination was 0.1-10 ng mL−1 for 1 mL sampling volume with a detection limit (3 s) of 0.01 ng mL−1. The relative standard deviation (RSD) was 2.4% for nine replicates of a 1 ng mL−1 germanium solution. The method was validated by the analysis of one non-certified and two certified geochemical reference materials, respectively, CRM GSJ-JR-2 (Rhyolite), and GSJ-JR-1 (Rhyolite), and GBW 07107 (Chinese Rock). Selectivity of the method was investigated for Cd2+, Co2+, Cu2+, Fe3+, Ga3+, Hg2+, Ni2+, Pb2+, Sn2+, and Zn2+ ions and ionic species of As(III), Sb(III), Te(IV), and Se(IV).  相似文献   
40.
Quantum Fisher Information (QFI) is a very useful concept for analyzing situations that require phase sensitivity. It become a popular topic especially in Quantum Metrology domain. In this work, we study the changes in quantum Fisher information (QFI) values for one relative arbitrary phased quantum system consisting of a superposition of N Qubits W and GHZ states. In a recent work (Ozaydin et al. Int. J. Theor. Phys. 52, 2977, 2013), QFI values of this mentioned system for N qubits were studied. In this work, we extend this problem for the changes of QFI values in some noisy channels for the studied system. We show the changes in QFI depending on noise parameters. We report interesting results for different type of decoherence channels. We show the general case results for this problem.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号