首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   74篇
  免费   0篇
化学   56篇
力学   2篇
数学   4篇
物理学   12篇
  2022年   4篇
  2021年   3篇
  2020年   4篇
  2019年   2篇
  2018年   4篇
  2017年   3篇
  2016年   2篇
  2014年   1篇
  2013年   2篇
  2012年   6篇
  2011年   6篇
  2010年   2篇
  2009年   7篇
  2008年   4篇
  2007年   7篇
  2006年   4篇
  2005年   4篇
  2004年   4篇
  2002年   2篇
  2001年   1篇
  1999年   1篇
  1997年   1篇
排序方式: 共有74条查询结果,搜索用时 15 毫秒
71.
Critical micelle concentrations (cmc) of aqueous solutions of poly(methyl methacrylate)-block-poly(N-isopropylacrylamide) were determined at several temperatures by surface tensiometry. Below the lower critical solution temperature (LCST), the low Delta mic H 0 determined can be assigned to the PMMA block being tightly coiled in the dispersed molecular state, so that the unfavorable interactions of hydrophobic entities with water are minimized. Above the LCST the cmc value was found to increase; an anomalous behavior that can be directly related to the micelle-globule transition of the hydrophilic block. Interestingly, above the LCST the surface tension of relatively concentrated solutions was found to depend weakly on temperature not following the usual strong decrease with temperature expected for aqueous solutions.  相似文献   
72.
The protein myoglobin has been successfully immobilized into a mesoporous metal-organic framework with hierarchical pore sizes, which demonstrates interesting size-selective biocatalysis as well as superior catalytic activities toward small substrate oxidation compared to its mesoporous silica material counterpart.  相似文献   
73.
The purpose of this study is to evaluate the ability of proton density (PD)-BLADE sequences in reducing or even eliminating motion and pulsatile flow artifacts in knee magnetic resonance imaging examinations. Eighty consecutive patients, who had been routinely scanned for knee examination, participated in the study. The following pairs of sequences with and without BLADE were compared: (a) PD turbo spin echo (TSE) sagittal (SAG) fat saturation (FS) in 35 patients, (b) PD TSE coronal (COR) FS in 19 patients, (c) T2 TSE axial in 13 patients and (d) PD TSE SAG in 13 patients. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion and pulsation artifacts was evaluated. Based on the results of the SNR, CRN and ReCon for the different sequences and anatomical structures, the BLADE sequences were significantly superior in 19 cases, whereas the corresponding conventional sequences were significantly superior in only 6 cases. BLADE sequences eliminated motion artifacts in all the cases. However, motion artifacts were shown in (a) six PD TSE SAG FS, (b) three PD TSE COR FS, (c) three PD TSE SAG and (d) two T2 TSE axial conventional sequences. In our results, it was found that, in PD FS sequences (sagittal and coronal), the differences between the BLADE and conventional sequences regarding the elimination of motion and pulsatile flow artifacts were statistically significant. In all the comparisons, the PD FS BLADE sequences (coronal and sagittal) were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable to potentially eliminate motion and pulsatile flow artifacts in MR images.  相似文献   
74.
This study aims in the examination of a new class of materials named polymer layered silicate nanocomposites. In our case, composites are usually combinations of polypropylene matrix with solid mineral reinforcements named silicates (e,g. montmorillonite, a natural clay). In this study, two complementary techniques used to characterize nanocomposites. Fourier transform infrared spectroscopy (FT-IR) both in transmission and attenuated total reflectance (ATR) modes combined with X-ray photoelectron spectroscopy (XPS).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号