首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   96篇
  免费   2篇
化学   72篇
数学   8篇
物理学   18篇
  2023年   1篇
  2019年   2篇
  2017年   1篇
  2016年   1篇
  2015年   2篇
  2014年   5篇
  2013年   7篇
  2012年   8篇
  2011年   4篇
  2010年   2篇
  2009年   6篇
  2008年   4篇
  2007年   6篇
  2006年   6篇
  2005年   4篇
  2004年   6篇
  2003年   2篇
  2002年   5篇
  2001年   2篇
  2000年   3篇
  1998年   1篇
  1997年   1篇
  1996年   5篇
  1994年   3篇
  1993年   2篇
  1992年   4篇
  1990年   2篇
  1986年   1篇
  1981年   1篇
  1980年   1篇
排序方式: 共有98条查询结果,搜索用时 46 毫秒
41.
In this study, DNA adsorption properties of polyethylenimine (PEI)-attached poly(p-chloromethylstyrene) (PCMS) beads were investigated. Spherical beads with an average size of 186 microm were obtained by the suspension polymerization of p-chloromethylstyrene conducted in an aqueous dispersion medium. Owing to the reasonably rough character of the bead surface, PCMS beads had a specific surface area of 14.1 m2/g. PEI chains could be covalently attached onto the PCMS beads with equilibrium binding capacities up to 208 mg PEI/g beads, via a direct chemical reaction between the amine and chloromethyl groups. After PEI adsorption with 10% (w/w) initial PEI concentration, free amino content of PEI-attached PCMS beads was determined as 0.91 mequiv./g. PEI-attached PCMS beads were utilized as sorbents in DNA adsorption experiments conducted at +4 degrees C in a phosphate buffer medium of pH 7.4. DNA immobilization capacities up to 290 mg DNA/g beads could be achieved with the tried sorbents. This value was approximately 50-times higher relative to the adsorption capacities of previously examined sorbents.  相似文献   
42.
Three digestion procedures have been tested on lichen samples for application in the determination of major, minor and trace elements (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V and Zn) in lichen samples collected in Aegean Region of Turkey by inductively coupled plasma atomic emission spectrometer (ICP-AES). The acid mixture of concentrated HNO3, H2O2 and HF were used. The instrument was optimized using lichen matrix considering RF power, nebulizer pressure, auxiliary flow rate and pump rate. The accuracy of the overall analyses was first estimated by analysis of two certified reference materials. Good agreement between measured and reference values were found for almost all elements. As the second way of determining the accuracy, results obtained from independent analytical techniques (ICP-AES and instrumental neutron activation analysis (INAA)) were compared for all elements by analyzing real samples. Correlation coefficients of two techniques for the elements ranged between 0.70 (Mg) and 0.96 (Fe). Among the three digestion systems, namely microwave, open vessel and acid bomb, microwave digestion system gave the best recovery results. The method detection limit (MDL) was computed using reagent blanks of microwave digestion system since it provides cleaner sample preparation. Detection limit is adequate for all elements to determine the elements in lichen samples. The precision was assessed from the replicate analyses of reagent blanks of microwave digestion system and was found to be less than 1.5% relative standard deviation (R.S.D.).  相似文献   
43.
44.
Ultrasound-assisted dispersive liquid–liquid microextraction was coupled with gas chromatography—mass spectrometry for the determination of phthalate esters in milk. Dimethyl phthalate, diethyl phthalate, dibutyl phthalate, benzyl butyl phthalate, bis(2-ethylhexyl) phthalate, and dioctyl phthalate were analyzed in five brands of pasteurized Turkish milk. The efficiencies of the extraction procedure for the analytes were between 66 and 100%. The linear dynamic ranges of the calibration curves were from 0.025 to 1.000 µg/mL with correlation coefficients exceeding 0.99. The precision of the method is acceptable with relative standard deviation values below 5%. Dibutyl phthalate and bis(2-ethylhexyl) phthalate were commonly observed in milk.  相似文献   
45.
In this study, poly(vinylphosphonic acid‐co‐ethylene dimethacrylate), poly(VPA‐co‐EDMA) capillary monolith was synthesized as a starting material for obtaining a stationary phase for microscale enrichment of phosphopeptides. The chelation of active phosphonate groups with Ti (IV) ions gave a macroporous monolithic column with a mean pore size of 5.4 μm. The phosphopeptides from different sources were enriched on Ti (IV)‐attached poly(VPA‐co‐EDMA) monolith using a syringe‐pump. The monolithic capillary columns exhibited highly sensitive/selective enrichment performance with phosphoprotein concentrations as low as 1.0 fmol/mL. Six different phosphopeptides were detected with high intensity by the treatment of β‐casein digest with the concentration of 1.0 fmol/mL, using Ti (IV)@poly(VPA‐co‐EDMA) monolith. Highly selective enrichment of phosphopeptides was also successfully carried out even at trace amounts, in a complex mixture of digested proteins (molar ratio of β‐casein to bovine serum albumin, 1:1500) and three phosphopeptides were successfully detected. Four highly intense signals of phosphopeptides in human serum were also observed with high signal‐to‐noise ratio and a clear background after enrichment with Ti (IV)@poly(VPA‐co‐EDMA) monolith. It was concluded that the capillary microextraction system enabled fast, efficient and robust enrichment of phosphopeptides from microscale complex samples. The whole enrichment process was completed within 20 min, which was shorter than in the previously reported studies.  相似文献   
46.
A rapid and specific proton magnetic resonance (PMR) spectroscopic method was developed for determining primidone in tablets. Maleic acid was used as the internal standart and DMSO-d6 served as the PMR solvent.  相似文献   
47.
Summary A capillary electrophoretic method for the determination of lansoprazole in pharmaceutical preparations is described. The analysis was performed in a fused silica capillary using 20 mM borate buffer at pH 8.7 as a background electrolyte. The best resolution was obtained by applying a potential of 30 kV and vacuum injection of 1 s. Detection was made at 200 nm. Phenobarbital sodium was a good internal standard and the migration times were 4.1±0.2 min (lansoprazole) and 5.7±0.2 min (phenobarbital sodium). A well-correlated calibration equation was found in the range of 1.12×10−5 and 2.24×10−4 M. Limit of detection (LOD) and limit of quantitation (LOQ) were 1.4×10−6 M (RSD 1.44%) and 4.42×10−6 M (RSD 1.49%), respectively. The method was validated and applied to the capsules containing enteric coated pellets of lansoprazole. The results of the proposed method were compared those of UV spectrophotometry. Insignificant differences were found between the two methods at the 95% probability level. The described CE method is selective, rapid, sensitive and accurate for the analysis of lansoprazole in quality control laboratories.  相似文献   
48.
In this study, click chemistry was proposed as a tool for tuning the surface hydrophilicity of monodisperse-macroporous particles in micron-size range. The monodisperse-porous particles carrying hydrophobic or hydrophilic molecular brushes on their surfaces were obtained by the proposed modification. Hydrophilic poly(glycidyl methacrylate-co-ethylene dimethacrylate), poly(GMA-co-EDM) particles were hydrophobized by the covalent attachment of poly(octadecyl acrylate-co-propargyl acrylate), poly(ODA-co-PA) copolymer onto the particle surface via triazole formation by click chemistry. In the second part, Hydrophobic poly(4-chloromethylstyrene-co-divinylbenzene), poly(CMS-co-DVB) particles were hydrophilized by the covalent attachment of poly(vinyl alcohol), PVA onto their surface also via triazole formation by click chemistry. The presence of PVA and poly(ODA-co-PA) copolymer on the corresponding particles was shown by FTIR-DRS. After click-coupling reactions applied for both hydrophobic poly(CMS-co-DVB) and hydrophilic poly(GMA-co-EDM) particles, the marked changes in surface polarity were shown by contact angle measurements. Protein adsorption characteristics of plain and modified particles were investigated for both materials. In the isoelectric point of albumin, the non-specific albumin adsorption decreased from 225 to 80 mg/g by grafting PVA onto the poly(CMS-co-DVB) beads. On the other hand, the non-specific albumin adsorption onto the plain poly(GMA-co-EDM) beads increased from 50 to 400 mg/g by the covalent attachment of poly(ODA-co-PA) copolymer onto the bead-surface via click chemistry. The protein adsorption behavior was efficiently regulated by the covalent attachment of appropriate molecular brushes onto the surfaces of selected particles. The results indicated that "click chemistry" was an efficient tool for controlling the polarity of monodisperse-macroporous particles.  相似文献   
49.
A new “grafting to” strategy was proposed for the preparation of polymer based ion exchange supports carrying polymeric ligands in the form of weak or strong ion exchangers. Monodisperse porous poly(glycidyl methacrylate-co-ethylene dimethacrylate), poly(GMA-co-EDM) particles 5.9 μm in size were synthesized by “modified seeded polymerization”. Poly(2,3-dihydroxypropyl methacrylate-co-ethylene dimethacrylate), poly(DHPM-co-EDM) particles were then obtained by the acidic hydrolysis of poly(GMA-co-EDM) particles. The hydroxyl functionalized beads were treated with 3-(trimethoxysilyl)propyl methacrylate to have covalently linked methacrylate groups on the particle surface. The selected monomers carrying weak or strong ionizable groups (2-acrylamido-2-methyl-1-propane sulfonic acid, AMPS; 2-dimethylaminoethylmethacrylate, DMAEM and N-[3-(dimethylamino)propyl] methacrylamide, DMAPM) were subsequently grafted onto the particles via immobilized methacrylate groups. The final polymer based materials with polyionic ligands were tried as chromatographic packing in the separation of proteins by ion exchange chromatography. The proteins were successfully separated both in the anion and cation exchange mode with higher column yields with respect to the previously proposed materials. The plate heights obtained for poly(AMPS) and poly(DMAEM) grafted poly(DHPM-co-EDM) particles by using proteins as the analytes were 80 and 200 μm, respectively. Additionally, the plate height exhibited no significant increase with the increasing linear flow rate in the range of 1–20 cm/min. The most important property of the proposed strategy is to be applicable for the synthesis of any type of ion exchanger both in the strong and weak form.  相似文献   
50.
Hydrophilic, polyacrylate-based, monosized-porous beads with zwitterionic molecular brushes were synthesized as a new stationary medium for hydrophilic interaction chromatography. Monosized-porous poly(glycerol-1,3-diglycerolate diacrylate-co-glycerol dimethacrylate), poly(GDGDA-co-GDMA), beads 5 μm in size were obtained by a staged-shape template polymerization. As an initiator for surface-initiated atom transfer radical polymerization (SI-ATRP), bromine functionality was obtained on the beads by reacting their hydroxyl groups with 3-(aminopropyl)triethoxysilane and α-bromoisobutyryl bromide, respectively. Zwitterionic molecular brushes on the hydrophilic poly(GDGDA-co-GDMA) beads were generated by SI-ATRP of a sulfobetaine monomer, [2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl) ammonium hydroxide (MESH). Poly(MESH)-grafted poly(GDGDA-co-GDMA), poly(MESH)g-poly(GDGDAco-GDMA), beads were slurry packed into the microbore columns with 2 mm i.d. and evaluated as stationary medium for the separation of organic acids, nucleosides and peptides using microbore columns in hydrophilic interaction chromatography with the plate numbers up to 30,000 plates m?1.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号