We have upgraded a Self-consistent-field – Hartree–Fock routine to include a finite nuclear mass correction for molecules developed in our laboratory. The new routine can handle isotopomers without calculating any nuclear kinetic energy matrix element. Tests on H2, LiH, HF, F2, and H2O isotopomers indicate the equivalence of our correction to the standard diagonal adiabatic correction. A further original application to C2H6 illustrates the usefulness of the method for polyatomic molecules. The resulting molecular orbitals carry the nuclear mass signature, exemplified with Koopmans ionization potentials.From the Proceedings of the 28th Congreso de Químicos Teóricos de Expresión Latina (QUITEL 2002) 相似文献
Summary This work describes the study of a degradation curve of Oxadixyl in field-treated potato and tomato samples. The residues
were extracted using classical and supercritical fluid (SFE) extraction methods and analyzed by HRGC/ECD. The extraction techniques
were compared and the results indicate the advantages of using SFE as an alternative method for pesticide analyses in these
samples. 相似文献
The 2-Phenyl-4,5-dimethylphosphorin P-W(CO)5 complex reacts easily as a dienophile with 2,3-dimethylbutadiene through its 1,6-positions and as a diene with N-phenylmaleimide, dimethyl acetylenedicarboxylate and cyclopentadiene, through its 1,4-positions. 相似文献
Organosolv (ethanol/water and acetosolv) pulps were treated with Bacillus pumilus xylanase for 4, 8, and 12 h and compared with commercial Cartazyme HS xylanase-treated pulps. Treatment of ethanol/water pulps with B. pumilus xylanase increased viscosity by 40% in 8 h of treatment compared with pulps treated without enzyme. However, acetosolv pulps treated with B. pumilus xylanase lost viscosity. Ethanol/water pulps treated with Cartazyme had a viscosity of 18.5 cP in 4 h of treatment. In the acetosolv pulps treated with commercial enzyme, the loss of viscosity was 20% compared with pulps treated without enzyme. Ethanol/water pulps treated with B. pumilus and Cartazyme had similar effects: a 44% reduction in kappa number for pulps treated with enzyme followed by alkaline extraction compared with pulps treated with alkaline extraction. In acetosolv pulps treated with B. pumilus, the kappa number was from 12 to 18, compared with pulps treated without enzyme, which had a 40% reduction in 4 and 12 h and a 60% reduction in 8 h. Cartazyme-treated acetosolv pulps had a kappa number of 14 in 4 and 8 h of treatment. For 12 h of treatment, the kappa number was 8. Fourier transform infrared spectra of the pulps showed that enzyme-treated pulps had changes in the 1000 cm?1 absorption owing to a C-O bond present in esters. Using principal component analysis, it is possible to differentiate the unbleached pulps and enzyme-treated pulps. 相似文献
A new liquid chromatographic (LC)-chemometric approach was developed for the determination of sunset yellow (SUN) and tartrazine (TAR) in commercial preparations. This approach uses LC and chemometric calibration methods, i.e., classical least-squares (CLS), principal component regression (PCR), and partial-least squares (PLS), simultaneously. The combined LC-chemometric approaches, denoted as LC-CLS, LC-PCR, and LC-PLS, are based on photodiode array (PDA) detection at multiple wavelengths. Optimum chromatographic separation of SUN and TAR with allura red as the internal standard (IS) was obtained by using a Waters Symmetry C18 column, 5 microm, 4.6 x 250 mm, and 0.2 M acetate buffer (pH 5)-acetonitrile-methano-bidistilled water (55 + 20 + 15 + 10, v/v) as the mobile phase at a flow rate of 1.9 mL/min. The LC data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using PDA detection at 5 wavelengths (465, 470, 475, 480, and 485 nm). LC-chemometric calibrations for SUN and TAR were separately constructed by using the relationship between the peak-area ratio and the training sets for each colorant. LC-chemometric approaches were tested for different synthetic mixtures containing SUN and TAR in the presence of the IS. These LC-chemometric calibrations were applied to a commercial preparation of the 2 colorants. The experimental results of the LC-chemometric approaches were compared with those obtained by a developed classical LC method using single-wavelength detection. 相似文献
Continuous 1-dimensional wavelet transform (WT) was applied to the quantitative analysis of a vitamin combination of thiamine hydrochloride (THI) and pyridoxine hydrochloride (PYR) with strongly overlapping signals. Absorbance data from the UV-Vis absorption spectrum of width 1150 were subjected to Gauss1 and Gauss2 WTs. Because of its flexibility, data processing, and its high signal amplitude, the continuous WT method is a powerful tool for analysis of multicomponent mixtures. By measuring the amplitude signals corresponding to the selected zero-crossing points of the transformed signal, we obtained the calibration curve. The validation of the calibration graphs was confirmed with different mixtures of THI and PYR at various concentration ratios. A brief explanation of the continuous wavelet method is given. MATLAB 6.5 software was used to perform the calculations. The results of our study were compared with those obtained by spectroscopic, chemometric, and liquid chromatographic methods, and good agreement was found. 相似文献
The study and extension of a simple automated clean-up method for polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) to a broad range of polychlorinated biphenyls (PCB) is described. The isolation of seven PCDD, ten PCDF, and three coplanar PCB (cPCB) is extended to eight monoortho substituted PCB and seven so-called "marker PCB" (Aroclor 1260) for fatty food samples. This enables quantification of 35 compounds - including all congeners with a WHO toxic equivalent factor (TEF)--in a single extraction and single purification step. The chromatographic behaviour of mono-ortho PCB and marker PCB on a variety of adsorbents, including basic alumina, has been studied. Partitioning of analytes through multi-column sequences is described and correlated with their structural and electronic properties, by use of molecular modelling calculations. The fractionation process available with the Power-Prep automated clean-up system enables rapid independent analysis of the different groups of compounds. Gas chromatography with high resolution mass spectrometry (GC-HRMS) is used for the PCDD/F and cPCB fraction and quadrupole ion-storage tandem in time mass spectrometry (GC-QISTMS) for analysis of the remaining PCB. A comparison study was performed on quality-control samples and real fatty food samples to evaluate the robustness of the new strategy compared with a reference method. On the basis of this simultaneous clean-up, a rapid simplified strategy for PCDD/F and selected PCB analysis determination is proposed for fatty food samples. 相似文献
A 23 full factorial experimental design was adopted to estimate the effects of three variables on the biodegradation of oil during
soil bioremediation: bioaugmentation seeding a mixed culture, addition of fertilizer or mineral media, and correction of initial
pH of the soil to 7.0. The tests were carried out in polyvinyl chloride reactors with 5.0 kg of crude oil-contaminated soil
at 14 g/kg. After screening the variables, soil bioremediation tests were conduced with varied C:N ratios, yielding an increase
in biodegradation of the oil heavy fraction from 24 to 65%, consumption of total n-paraffins, and a remarkable decrease in the concentration of residual polycyclic aromatic hydrocarbons of the soil. 相似文献
The use of crown ethers is a simple and rapid method for the separation and determination of strontium in various samples. After sample dissolution oxalate precipitation was carried out to remove K. Chromatographic separation of strontium from most inactive and radioactive interference was done with a crown ether. The chemical recovery was determined gravimetrically. Radiostrontium was then determined by liquid scintillation counting. 相似文献
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.
An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ1=μ2=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed. 相似文献