排序方式: 共有40条查询结果,搜索用时 515 毫秒
21.
Relevant equivalent circuit parameters and values of material constants of a piezoelectric resonator can be determined from measurements of its electrical input impedance as a function of frequency. The complex electrical impedance curves and the associated critical frequencies are the basis of this characterization by the piezoelectric resonance method. In this paper, the previously introduced concept of normalized electrical impedance of the lossy resonator, extended to include piezoelectric losses, is applied to the analysis of the effects of different types of intrinsic losses on peak values, bandwidths and characteristic frequencies. The resulting impedance patterns depend solely on the electromechanical coupling coefficient and the loss tangents, providing a useful tool for the analysis of low-Q resonators. The normalized impedance is experimentally evaluated from the basic data provided by an HP 4194A impedance analyser by means of specifically developed ASP programs. 相似文献
22.
P. Junnila M. Latvala R. Matilainen J. Tummavuori 《Analytical and bioanalytical chemistry》1999,365(4):325-331
The method parameters of an almost one century old method for analyzing nickel as dimethylglyoximate were critically examined for the analysis of nickel raw materials and many of the method parameters were observed to have a significant effect on the Ni recovery. Thus, because the Ni precipitation method parameters vary a lot in analytical literature and also in practice, the obtained Ni results by different methods are not comparable. During this study it was found that the double precipitation worked out perfectly in eliminating the effects of impurity elements. The residual Ni content in the filtrates should also be measured to obtain accurate and precise Ni results. In complexing the impurity elements, tartaric acid, stabilized by acetic acid, turned out to be effective, and when added to the sample solution before ammonium addition, the best pH conditions for homogenous Ni precipitation with dimethylglyoxime were obtained. The optimized Ni determination method described was found to be accurate and highly reproducible when tested with Ni concentrates and standard reference materials containing high Ni concentrations. 相似文献
23.
P. Junnila M. Latvala R. Matilainen J. Tummavuori 《Fresenius' Journal of Analytical Chemistry》1999,365(4):325-331
The method parameters of an almost one century old method for analyzing nickel as dimethylglyoximate were critically examined
for the analysis of nickel raw materials and many of the method parameters were observed to have a significant effect on the
Ni recovery. Thus, because the Ni precipitation method parameters vary a lot in analytical literature and also in practice,
the obtained Ni results by different methods are not comparable. During this study it was found that the double precipitation
worked out perfectly in eliminating the effects of impurity elements. The residual Ni content in the filtrates should also
be measured to obtain accurate and precise Ni results. In complexing the impurity elements, tartaric acid, stabilized by acetic
acid, turned out to be effective, and when added to the sample solution before ammonium addition, the best pH conditions for
homogenous Ni precipitation with dimethylglyoxime were obtained. The optimized Ni determination method described was found
to be accurate and highly reproducible when tested with Ni concentrates and standard reference materials containing high Ni
concentrations.
Received: 26 December 1998 / Revised: 12 April 1999 / Accepted: 14 April 1999 相似文献
24.
Three sharp absorption features in the energy range 2.36–2.55 eV have been detected in the transmission spectrum of Co-diffused ZnSe, and a number of luminescence transitions originating from the lowest of these states at 2.361 eV have been observed. Photoluminescence excitation spectra prove that these are high energy excited states of the Co2+Zn impurity, a conclusion confirmed by comparison of measured and predicted luminescence energies. This represents the first identification of luminescence branching from a higher excited state of a transition metal ion in any semiconductor. The sharp, weakly phonon-coupled transitions involve either intra-impurity excitation or transitions from the impurity to localised states split off from a minimum in the conduction band. The implications of these observations for the mechanism of host-impurity energy transfer and for the nature of the excited state wavefunctions are discussed. 相似文献
25.
Hydrogenic (two-body) systems are the only atomic systems for which uncertainties in calculations of the energy levels approach the current state of the art in frequency measurement. This article discusses progress in the theory and measurement of transition frequencies in hydrogenic systems. These studies have relevance to the determination of fundamental constants and the testing of physical theories, especially quantum electrodynamics. A set of high accuracy calculable frequency standards could also be realized by using hydrogenic systems. 相似文献
26.
A direct sample fraction deposition method was developed for off-line size-exclusion chromatography (SEC)/matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. By using electrospray, the SEC eluent, together with a suitable matrix solution added coaxially, was directly deposited on the MALDI plate. Owing to the formation of very small droplets in electrospray, solvent evaporation is much faster. The fractionation volume in narrow-bore SEC, which can directly be collected in one MALDI spot, can easily be optimized in the range of a few microlitres. In addition, fairly homogeneous sample spots were obtained. The possible influence of composition variation of the SEC effluent on the analytical results using direct fraction deposition was investigated; no substantial effects were observed. The applicability of the method was demonstrated by characterizing a broad poly(methyl methacrylate) sample. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
27.
28.
29.
30.