We show that in the framework of grand unified theory (GUT) with anomalous U(1)(A) gauge symmetry, the success of the gauge coupling unification in the minimal SU(5) GUT is naturally explained, even if the mass spectrum of superheavy fields does not respect SU(5) symmetry. Because the unification scale for most realizations of the theory becomes smaller than the usual GUT scale, it suggests that the present level of experiments is close to that sufficient to observe proton decay via dimension 6 operators, p-->e+pi. 相似文献
The purpose of this paper was to investigate the feasibility of a newly developed hyperspectral fundus imaging camera with
a liquid crystal tunable filter. The intensities of different wavelengths of light transmitted through an artery, vein, and
the area surrounding these vessels and reflected out were measured, and the differential spectral absorptions were analyzed.
Measurements were made from 16 normal eyes and from two artificial capillaries. The ratios of absorption (ROA) of arteries
to veins from 500 to 580 nm (range 1) and from 600 to 720 nm (range 2) were calculated. For all eyes, the ROArange1 was larger than ROArange2. The ROA obtained from the artificial capillary filled with blood saturated with oxygen or nitrogen was similar to that of
simulated data of oxy- and deoxyhemoglobin extinction rate. Most ROAs of human eyes were lower than those of the simulated
data and the artificial capillaries. Oxygen saturation analysis by hyperspectral fundus imaging of retinal vessels were qualitatively
in agreement with thein vitro analysis or simulated values. However, further improvements are necessary to evaluate the oxygen saturation quantitatively
in the retinal blood vessels. 相似文献
Cortisol levels in body fluids are useful for monitoring the function of the pituitary-adrenal axis. Here, we established an “enzyme-linked immunometric assay” (a noncompetitive-type ELISA) for cortisol based on idiotype-anti-idiotype reactions. Six different anti-idiotype monoclonal antibodies that recognized the variable regions of a newly established anti-cortisol antibody were generated using hybridoma technology; these were two β-type and four α-type anti-idiotype antibodies, recognizing the paratope and framework regions, respectively. An immunometric assay was established using a combination of a selected α-type and a selected β-type antibody. The analyte (cortisol) was captured by an excess amount of anti-cortisol antibody immobilized on microplates, and the unoccupied paratope was saturated with the β-type antibody. Hapten-occupied anti-cortisol antibody, with less steric hindrance, was then selectively bound by the α-type antibody, labeled with biotin. The amount of biotin residue on the microplates was colorimetrically monitored using a peroxidase-labeled streptavidin. This assay had an approximately threefold higher sensitivity (detection limit: 90 pg = 248 fmol cortisol) than a competitive ELISA using the same anti-cortisol antibody, as well as a practical specificity for providing reasonable determination of normal urinary cortisol levels. 相似文献
Measurement of cortisol levels in body fluids is important for monitoring pituitary gland and adrenal functions. To develop a specific and standardized enzyme-linked immunosorbent assay (ELISA), a novel monoclonal anti-cortisol antibody has been generated using a reasonably designed haptenic derivative. Spleen cells were prepared from the BALB/c or A/J mouse, which had repeatedly been immunized with a conjugate of 4-(2-carboxyethylthio)cortisol (CET) and bovine serum albumin, to be fused with P3/NS1/1-Ag4-1 myeloma cells. After four fusion experiments, one hybridoma clone secreting a practical antibody has been established. The resulting monoclonal antibody CS#38 (isotype gamma1, kappa) showed an affinity constant (K(a)) for cortisol of 1 x 10(9) M(-1) and provided a practical calibration curve (detection limit, 0.26 ng per assay) in a homologous ELISA system employing horseradish peroxidase-labeled CET as a labeled antigen. Cross-reactivities with related C-21 steroids were acceptably low: 11-deoxycortisol (4.3%), cortisone (4.0%), corticosterone (1.9%), progesterone (1.6%), 17alpha-hydroxyprogesterone (12%), 6beta-hydroxycortisol (8.4%), and tetrahydrocortisol (< 0.1%). Urinary and serum cortisol levels of healthy volunteers were determined by this method after methylene chloride extraction to be 39.0 +/- 17.0 microg/day (n = 7) and 80.8 +/- 38.9 ng/mL (n = 10), respectively, both of which are in the reference range. 相似文献
The electronic and structural behaviour of a Pr(III) complex with 4,7-diphenyl-1,10-phenanthroline, [Pr(bathophen)(2)(NO(3))(3)], is investigated with respect to the effect of configuration changes on the Pr(III) centre. [Pr(bathophen)(2)(NO(3))(3)] luminesces from the excited states of the ligand and the metal ion. The fluorescence, ff-emission ((1)D(2)-->(3)H(4)), and phosphorescence bands appear at 394, 608.2 and 482 nm, respectively, in the solid state. In acetonitrile, the complex also shows multiple emissions. From the time-resolved emission and the lifetime measurements, the excitation energy-transfer in [Pr(bathophen)(2)(NO(3))(3)] is clarified, that is, the upper excited triplet level of the ligand acts as an energy donor, while the (1)D(2) levels of Pr(III) is the acceptor. Additionally, the emission phenomena of the complex can be modified by molecular distortion, particularly by rotation of the phenyl groups in the ligand. 相似文献
The authors describe a pipette type of biosensor for detecting target genes and using a zinc finger protein fused to luciferase (ZF luciferase). The ZF protein binds to a specific DNA sequence, and the target double-stranded (ds) DNA can be detected by monitoring the enzymatic activity of ZF luciferase. A small avidin-immobilized reaction plate is placed on a plastic pipette tip (referred to as Biologi tip). The dsDNA detection procedures are carried out by using a programmable dispensing robot equipped with a photodetector. These procedures include (a) the aspiration of an analyte to capture the biotinylated target dsDNA (a product of a polymerase chain reaction) on the small reaction plate inside the pipette tip, (b) the introduction of ZF luciferase and luciferin into the pipette tip, and (c) migration of the pipette tip to the detection port to measure bioluminescence on the small reaction plate. The emission originating from luciferase activity is observed on the reaction plate containing immobilized biotin-tagged target dsDNA, whereas plates containing non-target or biotinylated single-stranded DNA only do not yield a signal. The intensity of emission increases proportionally to the concentration of dsDNA, and the detection limit of the target dsDNA is as low as 62 pM. An actual genomic DNA sample from Escherichia coli O157 was successfully detected by this automatic analyzer using the Biologi tip equipped with a reaction plate. This indicates that this system has a large potential for practical applications, including in particular point-of-care analyses in hygiene control, food safety testing, and clinical diagnosis.
Graphical abstract A pipette-type biosensor was developed to detect target genes using a luciferase-fused zinc finger protein, where a small NeutrAvidin-immobilized reaction plate was placed on the tip, and the biotinylated target double-stranded DNA was detected by monitoring the bound luciferase activity.
ABSTRACT Miniature crystal models of six small carbohydrates were examined using the PM3 semiempirical quantum mechanics method. The minicrystal structures, consisting of 27 sugar residues, were optimized by the combined procedure of partial optimization and reconstruction of the model, while maintaining the original crystal symmetries. All of the minicrystals were successfully optimized without exhibiting a great increase in an energy at any reconstruction step. Some minicrystals showed a prolonged behavior of optimization cycles. A major source of structure change appeared to arise from hydroxyl group rotations wherein the largest movements mostly occurred in an early optimization stage. No significant deformations in geometry of either residues or hydrogen bonds were observed in the final minicrystal structures. The thermodynamic values calculated for the optimized minicrystals were in reasonably good agreement with the literature data. The present study indicated that the PM3 semiempirical method successfully predicted the basic features of intermolecular hydrogen bonding involved in a condensed system. 相似文献
The reductive cleavage of the C–O bonds of aryl ethers has great potential in organic synthesis. Although several catalysts that can promote the reductive cleavage of aryl ethers have been reported, all such systems require the use of an external reductant, e.g., hydrosilane or hydrogen. Here, we report the development of a new nickel-based catalytic system that can cleave the C–O bonds of ethers in the absence of an external reductant. The hydrogen atom required in this new reductive cleavage reaction is provided by the alkoxy group of the substrate, which serves as an internal reductant. The absence of an external reductant enables the unique chemoselectivity, i.e., the selective reduction of an alkoxy group over alkenes and ketones. 相似文献