首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   49篇
  免费   1篇
化学   24篇
晶体学   4篇
物理学   22篇
  2014年   1篇
  2012年   1篇
  2011年   4篇
  2010年   1篇
  2009年   2篇
  2008年   1篇
  2007年   3篇
  2006年   5篇
  2005年   2篇
  2004年   3篇
  2003年   3篇
  2000年   1篇
  1999年   1篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1993年   3篇
  1992年   1篇
  1991年   1篇
  1983年   1篇
  1982年   2篇
  1981年   1篇
  1980年   1篇
  1975年   1篇
  1973年   2篇
  1972年   2篇
  1967年   2篇
  1960年   1篇
排序方式: 共有50条查询结果,搜索用时 15 毫秒
21.
The depth-resolved luminescence of whispering gallery modes (WGMs) was studied in TiO2:Eu3+ microsphere using cathode luminescence. As the penetration depth of the electron beam into the microsphere was increased through the control of the accelerating voltage, periodic structures appeared superimposed over the intrinsic transition lines of Eu3+, which were attributable to the cavity enhancement effect of the spontaneous emission by WGM resonance. The calculated radial intensity distribution of the WGM and the penetration depth explained the observed dependence of the WGM structure's visibility on the accelerating voltage.  相似文献   
22.
We report the reaction dynamics of cobalt phthalocyanine (CoPc) molecules with Bi-line structures (BLSs) on a Si(1 0 0) surface, investigated using scanning tunneling microscopy (STM). When CoPc molecules were deposited on a Si(1 0 0) surface with BLSs at room temperature, single-spot protrusions were observed in the STM image instead of four-spot images corresponding to CoPcs flat molecular structure. Moreover, domains with a c(4 × 4) periodicity appeared on the terraces of the Si(1 0 0) surface. This indicates that CoPc molecules may have decomposed on the surface by catalytic reaction with Bi atoms.  相似文献   
23.
A method utilizing light polarization was applied to take the projection data of absorbers in a highly scattering medium. The floor level of the projection data due to diffused light was significantly suppressed by detection of photons which preserved initial polarization. An optical computed tomgraphy image was reconstructed from the projection data taken by this method and exhibited higher spatial resolution than the image reconstructed from the projection data by conventional method.  相似文献   
24.
Various amino acid esters and dicarboxylic acid esters having a β-thioether group have been synthesized and their polycondensation with diamine was found to occur at room temperature to form polyamide thioether. The effect of solvents or chelating agents on their polycondensation reaction was investigated. Metal acetylacetonates or inorganic salts had a great influence on the rate of the polycondensation reaction, and the catalytic activity of metal acetylacetonates M(AcAc)n or inorganic salts decreased in the following order: Mg(AcAc)2?Th(AcAc)4>Cu(AcAc)2>Li(AcAc)>None>Zr(AcAc)4, MgCl2·6H2O>CuCl2·.2H2O>ZnCl2>MgCl2>None. It was also found that the amount of polyamide thioether was dependent on solvents or the presence of chelating agents because the polycondensation rate and the apparent equilibrium between ring and chain structures were both greatly influenced by solvents or chelating agents. These effects of solvents or chelating agent on the polycondensation may be attributable to formation of a complex with the thioether group which enhances the reactivity of ester.  相似文献   
25.
Reactions of some imidazo[4,5-b]pyridine 4-oxides with phosphoryl chloride are described. Treatment of N-1-substituted imidazo[4,5-b]pyridine 4-oxides with phosphoryl chloride led to the predominant formation of 7-chloro derivatives. This feature was successfully applied to the preparation of a chloroimidazo[4,5-b]pyridine nucleoside, which served as an important precursor of 1-deazaadenosine.  相似文献   
26.
Cadmium species in river water were kinetically extracted with dithizone by varying the extraction time. The obtained extraction curve showed a three-stage stepwise profile that reflected the rate of the ligand substitution reaction between the dithizone and cadmium species. Corresponding to each stage, we divided these extracted cadmium species into three groups: "highly labile", "moderately labile" and "slowly labile" species.  相似文献   
27.
Several key improvements in crystal quality of bulk GaN grown by the ammonothermal method are presented. Full width at half maximum of (0 0 2) X-ray rocking curve was reduced to 53 and 62 arcsec for Ga-side and N-side, respectively. Transparent bulk GaN crystal was also demonstrated. Oxygen and sodium concentrations were reduced to mid-1018 and mid-1015 cm−3, respectively. We are currently searching for a growth condition that produces transparent bulk GaN with high structural quality and low impurities. Small-sized, semi-transparent GaN wafers were fabricated by slicing the grown bulk GaN crystals, which demonstrate the high feasibility of ammonothermal growth for production of GaN wafers.  相似文献   
28.
The peak shape of tris(2-methyl-8-quinolinolato)gallium(III) by reversed-phase high-performance liquid chromatography was found to be very sensitive to trace amounts of silanol groups on the surface of octadecylsylanized silica gel (ODS silica gel). The variation of the peak of the gallium(III) complex can be used as a probe of the residual silanol groups in an ODS column. The chromatographic peak parameters of the complex were compared with the silanol activities output by some silanol-detecting tests using nitrogen-containing compounds as probes. The comparison was performed with several commercially available ODS columns and laboratory-packed columns in which the amount of silanol groups was controlled by mixing fully endcapped ODS materials and a non-endcapped ODS material. The peak height was the most effective parameter among the peak parameters, and much more sensitive than the silanol-detecting tests using nitrogen-containing compounds, in detecting a trace amount of silanol groups that could not be detected by other silanol-detecting tests.  相似文献   
29.
Tris(2-methyl-8-quinolinolato)iron(III) was proposed as a sensitive spectrophotometric silanol-detecting probe based on the coordination ability of silanol groups on the surface of octadecylsylanized silica gel (ODS silica gel) for reversed-phase high-performance liquid chromatography. A peak of the iron(III) complex on a chromatogram abruptly collapsed as the silanol content in an ODS column increased, indicating that the iron(III) complex could sense trace amounts of silanol groups. The change of the peak parameters, such as the peak height and the peak area was highly related to the output of some nitrogen-containing compounds used as silanol-detecting probes as a function of the silanol content in an ODS column. The response of the peak height of the iron(III) complex to the silanol content was much more sensitive than the response of the nitrogen-containing probes, and was comparable to that of tris(2-methyl-8-quinolinolato)gallium(III), which had been proposed as a fluorometric silanol-detecting probe based on the coordination ability of the silanol groups.  相似文献   
30.
The fundamental performance of microangiography has been evaluated using the S‐band linac‐based inverse‐Compton scattering X‐ray (iCSX) method to determine how many photons would be required to apply iCSX to human microangiography. ICSX is characterized by its quasi‐monochromatic nature and small focus size which are fundamental requirements for microangiography. However, the current iCSX source does not have sufficient flux for microangiography in clinical settings. It was determined whether S‐band compact linac‐based iCSX can visualize small vessels of excised animal organs, and the amount of X‐ray photons required for real time microangiography in clinical settings was estimated. The iCSX coupled with a high‐gain avalanche rushing amorphous photoconductor camera could visualize a resolution chart with only a single iCSX pulse of ~3 ps duration; the resolution was estimated to be ~500 µm. The iCSX coupled with an X‐ray cooled charge‐coupled device image sensor camera visualized seventh‐order vascular branches (80 µm in diameter) of a rabbit ear by accumulating the images for 5 and 30 min, corresponding to irradiation of 3000 and 18000 iCSX pulses, respectively. The S‐band linac‐based iCSX visualized microvessels by accumulating the images. An iCSX source with a photon number of 3.6 × 103–5.4 × 104 times greater than that used in this study may enable visualizing microvessels of human fingertips even in clinical settings.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号