The Cr/SiO2 Phillips catalyst has taken a central role in ethylene polymerization ever since its discovery in 1953. This catalyst is unique compared to other ethylene polymerization catalysts, since it is active without the addition of a metal-alkyl co-catalyst. However, metal-alkyls can be added for scavenging poisons, enhancing the catalyst activity, reducing the induction period and altering polymer characteristics. Despite extensive research into the working state of the catalyst, still no consensus has been reached. Here, we show that by varying the type of metal-alkyl co-catalyst and its amount, the Cr redox chemistry can be tailored, resulting in distinct catalyst activities, induction periods, and polymer characteristics. We have used in-situ UV-Vis-NIR diffuse reflectance spectroscopy (DRS) for studying the Cr oxidation state during the reduction by tri-ethyl borane (TEB) or tri-ethyl aluminum (TEAl) and during subsequent ethylene polymerization. The results show that TEB primarily acts as a reductant and reduces Cr6+ with subsequent ethylene polymerization resulting in rapid polyethylene formation. TEAl generated two types of Cr2+ sites, inaccessible Cr3+ sites and active Cr4+ sites. Subsequent addition of ethylene also revealed an increased reducibility of residual Cr6+ sites and resulted in rapid polyethylene formation. Our results demonstrate the possibility of controlling the reduction chemistry by adding the proper amount and type of metal-alkyl for obtaining desired catalyst activities and tailored polyethylene characteristics. 相似文献
The discovery of biomarkers in easily accessible body fluids such as serum is one of the most challenging topics in proteomics requiring highly efficient separation and detection methodologies. Here, we present the application of a microfluidics-based LC-MS system (chip-LC-MS) to the label-free profiling of immunodepleted, trypsin-digested serum in comparison to conventional capillary LC-MS (cap-LC-MS). Both systems proved to have a repeatability of approximately 20% RSD for peak area, all sample preparation steps included, while repeatability of the LC-MS part by itself was less than 10% RSD for the chip-LC-MS system. Importantly, the chip-LC-MS system had a two times higher resolution in the LC dimension and resulted in a lower average charge state of the tryptic peptide ions generated in the ESI interface when compared to cap-LC-MS while requiring approximately 30 times less (~5 pmol) sample. In order to characterize both systems for their capability to find discriminating peptides in trypsin-digested serum samples, five out of ten individually prepared, identical sera were spiked with horse heart cytochrome c. A comprehensive data processing methodology was applied including 2-D smoothing, resolution reduction, peak picking, time alignment, and matching of the individual peak lists to create an aligned peak matrix amenable for statistical analysis. Statistical analysis by supervised classification and variable selection showed that both LC-MS systems could discriminate the two sample groups. However, the chip-LC-MS system allowed to assign 55% of the overall signal to selected peaks against 32% for the cap-LC-MS system. 相似文献
A fixed-point-free group G of automorphisms of an abelian group is shown to be locally finite if any two elements of G generate a finite subgroup. 相似文献
Block copolymer micelles with bactericidal properties were designed to deactivate pathogens such as E. coli bacteria. The micelles of PS‐b‐PAA and PS‐b‐P4VP block copolymers were loaded with biocides TCMTB or TCN up to 20 or 30 wt.‐%, depending on the type of antibacterial agent. Bacteria were exposed to loaded micelles and bacterial deactivation was evaluated. The micelles loaded with TCN are bactericidal; bacteria are killed in less than two minutes of exposure. The most likely interpretation of the data is that the biocide is transferred to the bacteria by repeated micelle/bacteria contacts, and not via the solution.
A combined (triplex) immunoassay for the simultaneous detection of three mycotoxins in grains was developed with superparamagnetic colour-encoded microbeads, in combination with two bead-dedicated flow cytometers. Monoclonal antibodies were coupled to the beads, and the amounts of bound mycotoxins were inversely related to the amounts of bound fluorescent labelled mycotoxins (inhibition immunoassay format). The selected monoclonal antibodies were tested for their target mycotoxins and for cross-reactivity with relevant metabolites and masked mycotoxins. In the triplex format, low levels of cross-interactions between the assays occurred at irrelevant high levels only. All three assays were influenced by the sample matrix of cereal extracts to some extent, and matrix-matched calibrations are recommended for quantitative screening purposes. In a preliminary in-house validation, the triplex assay was found to be reproducible, sensitive and sufficiently accurate for the quantitative screening at ML level. The triplex assay was critically compared to liquid chromatography–tandem mass spectrometry using reference materials and fortified blank material. Results for the quantification of ochratoxin A and zearalenone were in good agreement. However, the fumonisin assay was, due to overestimation, only suitable for qualitative judgements. Both flow cytometer platforms (Luminex 100 and FLEXMAP 3D) performed similar with respect to sensitivity with the advantages of a higher sample throughput and response range of the FLEXMAP 3D and lower cost of the Luminex 100.
The priciple of the direct inhibition microbead immunoassay using fluorescent mycotoxin-reporter conjugates 相似文献
Despite considerable efforts to synthesize nanotubes using porous alumina or polycarbonate membrane templates, few studies have addressed the resulting nanotube dispersion. We prepared dispersions of multilayered polyethylenimine/maleic anhydride alternating copolymer (PEI/MAAC) nanotubes synthesized with porous alumina templates. After mechanical polishing to remove the residual polymer surface layer from templates and subsequent template dissolution, the multilayered PEI/MAAC nanotubes were easily dispersed in water at neutral pH by polyelectrolyte adsorption, producing nanotube dispersions that were stable for at least 3 months. We characterized the dispersions using phase-contrast optical microscopy, electro-optics, electrophoresis, and viscometry to help understand their colloidal properties in the dilute and semidilute regimes. The dispersions were resistant to salt-induced aggregation up to at least 1 mM NaCl and were optically anisotropic when subjected to an electric field or flow. Interestingly, the electrophoretic mobility of polystyrene sulfonate (PSS)-stabilized nanotubes increases with increasing ionic strength, because of the high surface charge and softness of the adsorbed polyelectrolyte. Furthermore, unlike many rod-like colloid systems, the polymer nanotube dispersion has low viscosity because of weak rotary Brownian motions and strong tendency to shear thinning. At the high shear rates achieved in capillary viscometry experiments, however, we observed a slight shear thickening, which can be attributed to transient hydrocluster formation. 相似文献
An early clinical development study (phase I) was conducted to determine the usefulness of dried blood spot (DBS) sampling as an alternative to venous sampling for phenotyping and genotyping of CYP450 enzymes in healthy volunteers. Midazolam (MDZ) was used as a substrate for phenotyping CYP3A4 activity; the concentrations of MDZ and its main metabolite 1'-hydroxymidazolam (1-OH MDZ) were compared between the DBS method from finger punctures, plasma and whole blood (WB), drawn by venipuncture, whereby several methodological parameters were studied (i.e. punch width, amount of dots analyzed and storage time stability). Genotyping between DBS and venous WB samples was compared for CYP2D6 (*3, *4, *6), CYP2C19 (*2, *3), CYP3A4 (*1B) and CYP3A5 (*3C). In addition, the subject's and phlebotomist's satisfaction with venous blood sampling compared with the DBS method was evaluated using a standardized questionnaire. An LC-MS/MS method for the quantification of the MDZ and 1-OH MDZ concentrations in DBS samples was developed and validated in the range of 0.100-100 ng/mL. No compromises were made for the limits of quantification of the DBS-LC-MS/MS method vs the authentic plasma and WB methods. 相似文献
Photochemical damage to the retina occurs for prolonged exposures of intense light. Two action spectra exist for this phenomenon. In rat an action spectrum matching the absorption spectrum of rhodopsin was found. In macaque, the susceptibility for photochemical damage decreased continuously from the UV to long visible wavelengths. Later, such a spectrum was also found in rat. In search for critical parameters that determine the shape of the spectrum we gathered all available data on the damage threshold dose for monochromatic radiation and noted the experimental conditions. The rhodopsin action spectrum was found in two sources; the other 16 sources adhered to the short wavelength spectrum. Comparing the conditions we conclude that the critical parameters for the generation of either action spectrum remain elusive. Experiments are suggested to resolve this issue and fill a few gaps in our knowledge. 相似文献
Strong light-induced absorption has been observed in lithium niobate crystals doped with magnesium after application of femtosecond
illumination. In this material there are no Nb-on-Li-site defects and hence no antisite polarons occur, but small free polarons
close to the conduction band can be generated. The light-induced absorption observed is attributed to these polarons. For
LiNbO3:Mg, their decay times are about two orders of magnitude smaller than those of the Nb-on-Li-site polarons in undoped material.
The results are relevant for a better understanding of the suppression of the so-called optical damage in these crystals and
for their use in femtosecond applications. 相似文献