首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   43篇
  免费   1篇
化学   38篇
晶体学   1篇
力学   1篇
物理学   4篇
  2017年   1篇
  2015年   2篇
  2014年   2篇
  2013年   1篇
  2012年   7篇
  2011年   1篇
  2010年   2篇
  2008年   5篇
  2007年   2篇
  2006年   5篇
  2005年   4篇
  2004年   2篇
  2003年   4篇
  2002年   1篇
  2001年   1篇
  1999年   2篇
  1995年   1篇
  1983年   1篇
排序方式: 共有44条查询结果,搜索用时 328 毫秒
31.
The effect of corona pre-treatment on the performance of Al2O3 and SiO2 gas barrier layers applied by atomic layer deposition onto polymer-coated paperboards was studied. Both polyethylene and polylactide coated paperboards were corona treated prior to ALD. Corona treatment increased surface energies of the paperboard substrates, and this effect was still observed after several days. Al2O3 and SiO2 films were grown on top of the polymer coatings at temperature of 100 °C using the atomic layer deposition (ALD) technique. For SiO2 depositions a new precursor, bis(diethylamido) silane, was used. The positive effect of the corona pre-treatment on the barrier properties of the polymer-coated paperboards with the ALD-grown layers was more significant with polyethylene coated paperboard and with thin deposited layers (shorter ALD process). SiO2 performed similarly to Al2O3 with the PE coated board when it comes to the oxygen barrier, while the performance of SiO2 with the biopolymer-coated board was more moderate. The effect of corona pre-treatment was negligible or even negative with the biopolymer-coated board. The ALD film growth and the effect of corona treatment on different substrates require further investigation.  相似文献   
32.
The aim of the present study was to investigate the adsorption properties of aminopropyltriethoxysilane (APS) modified microfibrillated cellulose (MFC) in aqueous solutions containing Ni(II), Cu(II) and Cd(II) ions. The modified adsorbents were characterized using elemental analysis, Fourier transform infrared spectroscopy, SEM and zeta potential analysis. The adsorption and regeneration studies were conducted in batch mode using various different pH values and contact times. The maximum removal capacities of the APS/MFC adsorbent for Ni(II), Cu(II), and Cd(II) ions were 2.734, 3.150 and 4.195 mmol/g, respectively. The Langmuir, Sips and Dubinin-Radushkevich models were representative to simulate adsorption isotherms. The adsorption kinetics of Ni(II) Cu(II), and Cd(II) adsorption by APS/MFC data were modeled using the pseudo-first-order, pseudo-second-order and intra-particle diffusion kinetics equations. The results indicate that the pseudo-second-order kinetic equation and intra-particle diffusion model were adequate to describe the adsorption kinetics.  相似文献   
33.
Metal detector: a bowl-shaped nanomolecule (see picture; S yellow, C gray, Zn blue) containing an unprecedented 16-atom [ZnC(3)](4) "anti-crown" ring has been unearthed by isolating a dizincated 2-substituted thiophene intermediate that would normally be hidden in tandem functionalization methodology.  相似文献   
34.
We have characterized commercially available up-converting inorganic lanthanide phosphors for their rare earth composition and photoluminescence properties under infrared laser diode excitation. These up-converting phosphors, in contrast to proprietary materials reported earlier, are readily available to be utilized as particulate reporters in various ligand binding assays after grinding to submicron particle size. The laser power density required at 980 nm to generate anti-Stokes photoluminescence from these particulate reporters is significantly lower than required for two-photon excitation. The narrow photoluminescence emission bands at 520–550 nm and at 650–670 nm are at shorter wavelengths and thus totally discriminated from autofluorescence and scattered excitation light even without temporal resolution. Transparent solution of colloidal bead-milled up-converting phosphor nanoparticles provides intense green emission visible to the human eye under illumination by an infrared laser pointer. In this article, we show that the unique photoluminescence properties of the up-converting phosphors and the inexpensive measurement configuration, which is adequate for their sensitive detection, render the up-conversion an attractive alternative to the ultraviolet-excited time-resolved fluorescence of down-converting lanthanide compounds widely employed in biomedical research and diagnostics.  相似文献   
35.
The stability of seven polycyclic aromatic hydrocarbons (PAHs) were studied in aqueous solutions at 100-350 degrees C. The aqueous solution of one PAH compound at a time was sealed in a stainless steel bomb-type reaction vessel in an argon atmosphere and heated for 10 to 240 min in an oven. The contents of the vessel were analysed by GC-MS. At 300 degrees C, degradation was observed even with the shortest heating time, 10 min. The degradation products were typically different oxidation products such as ketones and quinones. In addition to the heating time and temperature, the concentration of the analyte and the inner surface of the vessel affected the results.  相似文献   
36.
The adsorption of polyelectrolyte (PE) multilayers and complexes, obtained from both high- and low-charge polyelectrolytes, was studied on silica and on cellulose model surfaces by quartz crystal microbalance with dissipation (QCM-D). The film properties acquired with the different strategies were compared. When polyelectrolytes were added on an oppositely charged surface in sequence to form multilayers both the change in frequency and dissipation increased. The changes in frequency and dissipation were clearly higher if low-charge PEs were used in the multilayer formation. The substrate, silica or cellulose, did not affect the adsorption behaviour of low-charge PEs and only minor differences were seen in the adsorbed amounts and changes in dissipation of high-charge PEs between SiO2 and cellulose. The complexes formed by low-charge PEs had higher changes in frequency and dissipation at low ionic strength on both surfaces, while the complexes formed from high-charge polyelectrolytes adsorbed more at high salt concentration. The complexes of low-charge polyelectrolytes adsorbed more on silica, while the complexes formed by high-charge PEs formed thicker layers on cellulose. The charge ratio had a significant effect on the adsorption and the highest changes in frequency and dissipation were obtained in the anionic/cationic charge ratio of 0.5–0.6. Generally, the multilayers and complexes formed by low-charge polyacrylamides adsorbed highly and formed rather thick layers on both surfaces, unlike the high-charge PEs which formed thin layers using either one of the addition techniques.  相似文献   
37.
 Particulate matter of Diesel emissions collected from diluted exhaust during standard test runs with two Diesel fuels of different sulfur content was analysed by total-reflection X-ray fluorescence (TXRF). The trace elements determined were S, Ca, Cr, Mn, Fe, Ni, Cu, Zn and Pb. Additionally, some filter materials were tested with respect to their applicability for sample collection. Quartz fibre filters were found to be most suitable, both from a technical and a chemical point of view. A clear reduction of total particulate emissions during the whole test was observed when the fuel with very low sulfur content was used. In addition, it was found that the wear metal content of particulate matter emitted by a cold engine was higher than that observed during normal engine working temperature. Received September 10, 1998. Revision March 2, 1999  相似文献   
38.
39.
40.
Caspase proteases are key mediators in apoptosis and thus of great interest in pharmaceutical industry. Enzyme-activity assays are commonly employed in the screening of protease inhibitors that are potential drug candidates. Conventional homogeneous fluorescence-based assays are susceptible to autofluorescence originating from biological material. This background autofluorescence can be eliminated by using upconverting phosphors (UCPs) that emit visible light upon excitation at near-infrared. In the assay energy was transferred from a UCP-donor to a conventional fluorophore acceptor that resided at one end of a caspase-3-specific substrate peptide. Attached to the other end was a quencher molecule that was used to attenuate the acceptor emission through intramolecular energy transfer in an intact peptide. In non-inhibitory conditions the enzyme reaction separated the fluorophore from the quencher and the emission of the fluorophore was recovered. The method was applied for the detection and characterization of a known caspase-3 inhibitor Z-DEVD-FMK, and the assay gave IC50 values of approximately 13 nM for this inhibitor. We have demonstrated the applicability of UCPs on a fluorescence-quenching-based homogeneous enzyme-activity assay for the detection of caspase-3 inhibitors. The use of near-infrared excitable UCPs enables inexpensive instrumentation and total elimination of autofluorescence, while the use of an internally quenched substrate molecule diminishes the background resulting from radiatively excited acceptor molecules. The reduction of autofluorescence and radiative background result in high signal-to-background ratios (ratios of approximately 100 were obtained). By further utilizing assay miniaturization and signal enhancement in a white microtitration plate, a significant reduction in the reagent consumption can be achieved rendering the assay applicable for high-throughput screening.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号