We have efficiently produced collagen-rich microstructures in fibroblast multicellular spheroids (MCSs) as a three-dimensional in vitro tissue analog to investigate silver (Ag) nanoparticle (NP) penetration. The MCS production was examined by changing the seeding cell number (500 to 40,000 cells) and the growth period (1 to 10 days). MCSs were incubated with Ag NP suspensions with a concentration of 5 μg mL−1 for 24 h. For this study, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used to visualize Ag NP localization quantitatively. Thin sections of MCSs were analyzed by LA-ICP-MS with a laser spot size of 8 μm to image distributions of 109Ag, 31P, 63Cu, 66Zn, and 79Br. A calibration using a NP suspension was applied to convert the measured Ag intensity into the number of NPs present. The determined numbers of NPs ranged from 30 to 7200 particles in an outer rim of MCS. The particle distribution was clearly correlated with the presence of 31P and 66Zn and was localized in the outer rim of proliferating cells with a width that was equal to about twice the diameter of single cells. Moreover, abundant collagens were found in the outer rim of MCSs. For only the highest seeding cell number, NPs were completely captured at the outer rim, in a natural barrier reducing particle transport, whereas Eosin (79Br) used as a probe of small molecules penetrated into the core of MCSs already after 1 min of exposure.
Fibroblast MCS could build up the barrier only for nanoparticles
New systems for millimeter and submillimeter wave ESR have been developed in Kobe University. In the previous system the pulsed magnetic field was limited up to 17 T in the temperature range from 1.8 to 86 K. Using the new systems, we can measure in the field range up to 30 T in the temperature range from 1.8 K to 4.2 K and from 18 K to room temperature. The resolution of the magnetic field has been also improved in the new ESR system. The details of our new ESR systems are presented. In addition, the measurements of Yb2Cu2O5 using these new systems are presented. 相似文献
This paper is concerned with cross-validation (CV) criteria for choice of models, which can be regarded as approximately unbiased
estimators for two types of risk functions. One is AIC type of risk or equivalently the expected Kullback-Leibler distance
between the distributions of observations under a candidate model and the true model. The other is based on the expected mean
squared error of prediction. In this paper we study asymptotic properties of CV criteria for selecting multivariate regression
models and growth curve models under the assumption that a candidate model includes the true model. Based on the results,
we propose their corrected versions which are more nearly unbiased for their risks. Through numerical experiments, some tendency
of the CV criteria will be also pointed. 相似文献
A laser ablation-inductively coupled plasma-mass spectrometric (LA-ICPMS) technique utilizing a titanium-sapphire (TiS) femtosecond laser (fs-laser) has been developed for elemental and isotopic analysis. The signal intensity profile, depth of the ablation pit and level of elemental fractionation were investigated in order to evaluate the analytical capability of the present fs-laser ablation-ICPMS technique. The signal intensity profile of (57)Fe, obtained from iron sulfide (FeS(2)), demonstrated that the resulting signal intensity of (57)Fe achieved by the fs-laser ablation was almost 4-times higher than that obtained by ArF excimer laser ablation under a similar energy fluence (5 J/cm(2)). In fs-laser ablation, there is no significant difference in a depth of the ablation pit between glass and zircon material, while in ArF laser ablation, the resulting crater depth on the zircon crystal was almost half the level than that obtained for glass material. Both the thermal-induced and particle size-related elemental fractionations, which have been thought to be main sources of analytical error in the LA-ICPMS analysis, were measured on a Harvard 91500 zircon crystal. The resulting fractionation indexes on the (206)Pb/(238)U (f(Pb/U)) and (238)U/(232)Th (f(U/Th)) ratios obtained by the present fs-laser ablation system were significantly smaller than those obtained by a conventional ArF excimer laser ablation system, demonstrative of smaller elemental fractionation. Using the present fs-laser ablation technique, the time profile of the signal intensity of (56)Fe and the isotopic ratios ((57)Fe/(54)Fe and (56)Fe/(54)Fe) have been measured on a natural pyrite (FeS(2)) sample. Repeatability in signal intensity of (56)Fe achieved by the fs-laser ablation system was significantly better than that obtained by ArF excimer laser ablation. Moreover, the resulting precision in (57)Fe/(54)Fe and (56)Fe/(54)Fe ratio measurements could be improved by the fs-laser ablation system. The data obtained here clearly demonstrate that, even with the fundamental wavelength (NIR operating at 780 nm), the fs-laser ablation system has the potential to become a significant tool for in-situ elemental and isotopic analysis of geochemical samples including heavy minerals and metallic materials. 相似文献
[reaction: see text] The first catalytic asymmetric synthesis of 2-aryl-2,3-dihydro-4-quinolones has been developed by way of a rhodium-catalyzed 1,4-addition of arylzinc reagents to 4-quinolones. These 1,4-adducts can be obtained with high enantioselectivity by the use of (R)-binap as a ligand, and high yields are realized by conducting the reactions in the presence of chlorotrimethylsilane. 相似文献
Chiral calixarene analogs incorporating cystine peptide into their macrocyclic ring were easily prepared by the cyclization reactions of bis(chloromethyl)phenol-formaldehyde oligomers with cystine peptides in moderate yields. Circular dichroism (CD) spectra indicated the existence of the transmission of the chirality from peptide unit to phenol-formaldehyde oligomer moiety. 相似文献