首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   117篇
  免费   3篇
化学   100篇
数学   8篇
物理学   12篇
  2024年   3篇
  2023年   1篇
  2022年   5篇
  2021年   7篇
  2020年   6篇
  2019年   3篇
  2018年   10篇
  2017年   7篇
  2016年   5篇
  2015年   5篇
  2014年   3篇
  2013年   13篇
  2012年   10篇
  2011年   5篇
  2010年   4篇
  2009年   5篇
  2008年   7篇
  2007年   2篇
  2006年   4篇
  2005年   2篇
  2004年   2篇
  2003年   2篇
  2002年   4篇
  2001年   4篇
  1998年   1篇
排序方式: 共有120条查询结果,搜索用时 46 毫秒
51.
In this work, microporous substrates modified by zeolite nanoparticles were prepared and used for composite membrane making with the aim of reducing internal concentration polarization (ICP) effect of membranes during engineered osmosis applications. Nanocomposite substrates were fabricated via phase inversion technique by embedding nanostructured zeolite (clinoptilolite) in the range of 0–0.6 wt% into matrix of polyethersulfone (PES) substrate. Of all the substrates prepared, the PES0.4 substrate (with 0.4 wt% zeolite) exhibited unique characteristics, i.e., increased surface porosity, lower structural parameter (S) (from 0.78 to 0.48 mm), and enhanced water flux. The thin film nanocomposite (TFN) membrane made of this optimized substrate was also reported to exhibit higher water flux compared to the control composite membrane during forward osmosis (FO) and pressure-retarded osmosis (PRO) test, without compromising reverse solute flux. The water flux of such TFN membrane was 43% higher than the control TFC membrane (1.93 L/m2 h bar) with salt rejection recorded at 94.7%. An increment in water flux is ascribed to the reduction in structural parameter, leading to reduced ICP effect.  相似文献   
52.
A PVC-based sensor for La3+ ions based on N-[hexahydrocyclopentapyrol-2((1H)yl)amino]carbonyl]-4-methyl benzene sulfonamide (gliclazide) as a novel carrier was prepared. The electrode exhibits a Nernstian response for La3+ over a wide concentration range (1.0×10−1-1.0×10−6 M) with a slope of 20.1 mV per decade. The limit of detection is 8.0×10−7 M. The sensor has a very short response time (<15 s) and a useful working pH range of 4.0-8.0. The proposed membrane sensor shows excellent discriminating ability towards La3+ ions with regard to several alkali, alkaline earth, transition and heavy metal ions. The electrode was successfully applied for determination of La3+ in binary mixtures.  相似文献   
53.
A highly selective electrode for iodide ion based on a thiopyrilium derivative as an excellent ionophore is described. At pH 5.5-8.0, the electrode responds to iodide ion in a linear range from 1.0×10−1 to 8.0×10−7 M with a slope of 60.2 mV per decade, and a detection limit of 2.0×10−7 M. Selectivity coefficients determined with the match potential method (MPM) indicate that the interference from inorganic and organic anions is very small. The proposed sensor shows a fast response time of approximately 15 s. It was applied as an indicator electrode in titration of iodide with Ag+.  相似文献   
54.
A highly sensitive and accurate method for preconcentration and determination of ultra trace amounts of cobalt and nickel ions in water samples is proposed. The preconcentration is achieved using C18-silica extraction disks modified with 5-(6-methoxy-2-benzothiazoleazo)-8-aminoquinoline (MBTAQ). The retained ions on the prepared solid phase was eluted with 10 ml of 0.01 M nitric acid and measured by inductively coupled plasma-optical emission spectrometry (ICP-OES). The influence of the type and amount of eluent used, pH, sample and eluent flow rates, amount of MBTAQ and the effect of other ions on extraction efficiency were investigated. The limits of detection of the method were 0.08 and 0.06 μg l− 1 for cobalt and nickel, respectively, and provide an enrichment factor of 100. The results obtained on 10 successive extractions and elution cycles revealed relative standard deviations of 1.5 and 1.0% for cobalt and nickel, respectively. The proposed method has been applied to the determination of ultra trace amounts of cobalt and nickel ions in natural and synthetic water samples with satisfactory results.  相似文献   
55.
The application of newly synthesized Fe3O4/TiO2–SiO2 that is modified with zinc (FTSZ) as a sorbent, for the removal of arsenic from contaminated water has been investigated in the present study. SEM, FTIR, XRD, BET, Zeta potential sizer (ξ) analyses are used to determine the sorbent characterization. The effect of the operational parameters such as initial pH, initial concentration, and the contact time were studied. In addition, the equilibrium behavior of FTSZ in As(III) removal was investigated in the temperature range of 20–40 °C. The results showed that the equilibrium data were fitted well with Langmuir than Freundlich isotherm model. The maximum monolayer adsorption capacity estimated by Langmuir isotherm was 24.010 mg g?1. Thermodynamic parameters, ?H°, ?S° and ?G° were also calculated from graphical interpretation of the experimental data. Standard heats of sorption (?H°) were found to be endothermic and ?S° values were calculated to be positive for the sorption of As(III) onto the adsorbent.  相似文献   
56.
A highly sensitive and accurate method for preconcentration and determination of ultra trace amounts of inorganic mercury and organomercury compounds in different water samples is proposed. The preconcentration is achieved using octadecyl silica (C18) extraction disks modified with 1,3-bis(2-cyanobenzene)triazene (CBT). The retained analytes as their triazenide complexes on the solid phase was eluted with 10 ml acetonitrile and measured by reversed-phase high-performance liquid chromatography (RP-HPLC). Type and amount of eluent, pH, amount of CBT, flow rates of sample solution and eluent have been optimized in order to obtain quantitative recovery of the analytes. The effect of interfering ions, such as Cu2+, Mn2+, Fe2+, Al3+, Zn2+, Cd2+, Ca2+, Mg2+, Ba2+, Pb2+, K+ and Na+ usually present in water samples on the recovery of the analytes has also been investigated. The enrichment factor of 100 was obtained for all mercury species and the analytical detection limits of phenylmercury, methylmercury and Hg2+ were found as 0.8, 1.0 and 1.3 ng l− 1, respectively. Stability of mercury species after extraction on the modified disks was studied and the results showed that complexes collected on the disks were stable for at least 5 days. The proposed method has been applied to the quantitative determination of mercury species in natural and synthetic water samples with recoveries more than 90%.  相似文献   
57.
A green, reliable synthetic method and highly efficient one-pot three-component synthesis of 2,4,5-trisubstituted imidazoles from 1,2-diketones, aldehydes and ammonium acetate in the presence of recyclable magnetic graphitic carbon nitride nanocomposite (Fe3O4@g-C3N4) has been developed. Various imidazole derivatives were obtained in moderate to excellent yields and high purity after recrystallization from ethanol. Interestingly, the low-cost Fe3O4@g-C3N4 a nontoxic and inexpensive catalyst showed excellent recyclability using an external magnet without loss of parent catalytic activity even after ten cycles and its provides new opportunities for the truly environmental friendliness methodology.  相似文献   
58.
Research on Chemical Intermediates - A magnetic graphitic carbon nitride (g-C3N4) nanocomposite was prepared and used as a novel magnetically retrievable nanocatalyst for efficient ring opening of...  相似文献   
59.
Numerical Algorithms - This paper is devoted to investigate the modified extended second derivative backward differentiation formulae from second derivative general linear methods point of view....  相似文献   
60.
A highly effective and mild protocol for ring opening of epoxides with NH 4 SCN in the presence of catalytic amount of a multisite phase-transfer catalyst, α,α',α" -N-hexakis(triethylammoniummethylene chloride)-melamine, is developed. A variety of b-hydroxy thiocyanates as important intermediates in agricultural and pharmaceutical chemistry were obtained in high yields with excellent regioselectivity and in short reaction times.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号