首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   79篇
  免费   2篇
  国内免费   1篇
化学   69篇
力学   2篇
数学   2篇
物理学   9篇
  2016年   1篇
  2015年   2篇
  2013年   1篇
  2012年   1篇
  2011年   9篇
  2010年   3篇
  2009年   2篇
  2008年   5篇
  2007年   4篇
  2006年   6篇
  2005年   3篇
  2004年   8篇
  2003年   7篇
  2002年   1篇
  2001年   3篇
  2000年   4篇
  1999年   5篇
  1998年   1篇
  1997年   1篇
  1996年   3篇
  1994年   1篇
  1993年   3篇
  1991年   2篇
  1990年   1篇
  1989年   1篇
  1988年   2篇
  1987年   1篇
  1984年   1篇
排序方式: 共有82条查询结果,搜索用时 546 毫秒
71.
A high-temperature configuration for a diaphragm valve-based gas chromatography (GCXGC) instrument is demonstrated. GCxGC is a powerful instrumental tool often used to analyze complex mixtures. Previously, the temperature limitations of valve-based GCxGC instruments were set by the maximum operating temperature of the valve, typically 175 degrees C. Thus, valve-based GCxGC was constrained to the analysis of mainly volatile components; however, many complex mixtures contain semi-volatile components as well. A new configuration is described that extends the working temperature range of diaphragm valve-based GCxGC instruments to significantly higher temperatures, so both volatile and semi-volatile compounds can be readily separated. In the current investigation, separations at temperatures up to 250 degrees C are demonstrated. This new design features both chromatographic columns in the same oven with the valve interfacing the two columns mounted in the side of the oven wall so the valve is both partially inside as well as outside the oven. The diaphragm and the sample ports in the valve are located inside the oven while the temperature-restrictive portion of the valve (containing the O-rings) is outside the oven. Temperature measurements on the surface of the valve indicate that even after a sustained oven temperature of 240 degrees C, the portions of the valve directly involved with the sampling from the first column to the second column track the oven temperature to within 1.2% while the portions of the valve that are temperature-restrictive remain well below the maximum temperature of 175 degrees C. A 26-component mixture of alkanes, ketones, and alcohols whose boiling points range from 65 degrees C (n-hexane) to 270 degrees C (n-pentadecane) is used to test the new design. Peak shapes along the first column axis suggest that sample condensation or carry-over in the valve is not a problem. Chemometric data analysis is performed to demonstrate that the resulting data have a bilinear structure. After over 6 months of use and temperature conditions up to 265 degrees C, no deterioration of the valve or its performance has been observed.  相似文献   
72.
Comprehensive two-dimensional (2D) separations provide the analyst with a tremendous amount of complex data. In order to glean useful information from this complex data, advancements in commercially available software that implement chemometrics are currently available and continue to evolve. Future advancements will no doubt involve commercializing (or adapting) specialized, in-house chemometric techniques that are currently found only in the hands of technical experts and researchers in industry, government, and academia. In order to make timely advancements, future commercialization of novel chemometric techniques should involve collaborations among instrument software manufacturers, professional programmers, technical experts, and researchers. During the last decade, this field has seen a steady advancement from single analyte target analysis to comprehensive non-target analysis of entire multidimensional sample profiles (involving sample classification and/or data mining for discovery-based sample comparisons). The advancements in instrumentation and chemometric software tools have a tremendous impact in various applications: fuels, food, environmental, pharmaceuticals, metabolomics, etc. Most of the development has been for software to apply with gas chromatography-based instrumentation, such as comprehensive two-dimensional gas chromatography (GC x GC) and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC x GC-TOF-MS). More recently there have been notable advancements in liquid-phase instrumentation as well.  相似文献   
73.
l-β-Methylamino-alanine (BMAA) has been proposed as a worldwide contributor to neurodegenerative diseases, including Parkinson dementia complex (PDC) of Guam and Alzheimer's disease (AD). Recent conflicting reports of the presence of this amino acid in human brain from patients affected by these diseases have made it necessary to develop methods that provide unambiguous detection in complex samples. Comprehensive two-dimensional gas chromatography coupled with time-of-flight-mass-spectrometry analysis (GC × GC–TOFMS) followed by a targeted Parallel Factor Analysis (PARAFAC) deconvolution method has been used recently in metabolomic investigations to separate, identify, and quantify components of complex biological specimens. We have extended and applied this methodology to the toxicological problem of detecting BMAA in extracts of brain tissue. Our results show that BMAA can be isolated from closely eluting compounds and detected in trace amounts in extracts of brain tissue spiked with low levels of this analyte, ranging from 2.5 ppb to 50 ppb, with a limit of detection (LOD) of 0.7 ppb. This new method was sufficiently sensitive to detect BMAA in cerebral extracts of mice fed BMAA. This optimized approach was then applied to analyze tissue from humans; however, no BMAA was detected in the brain extracts from controls or patients with PDC or AD. Our results demonstrate the application of multidimensional chromatography–mass spectrometry methods and computational deconvolution analysis to the problem of detecting trace amounts of a potential toxin in brain extracts from mice and humans.  相似文献   
74.
A useful methodology is introduced for the analysis of data obtained via gas chromatography with mass spectrometry (GC-MS) utilizing a complete mass spectrum at each retention time interval in which a mass spectrum was collected. Principal component analysis (PCA) with preprocessing by both piecewise retention time alignment and analysis of variance (ANOVA) feature selection is applied to all mass channels collected. The methodology involves concatenating all concurrently measured individual m/z chromatograms from m/z 20 to 120 for each GC-MS separation into a row vector. All of the sample row vectors are incorporated into a matrix where each row is a sample vector. This matrix is piecewise aligned and reduced by ANOVA feature selection. Application of the preprocessing steps (retention time alignment and feature selection) to all mass channels collected during the chromatographic separation allows considerably more selective chemical information to be incorporated in the PCA classification, and is the primary novelty of the report. This methodology is objective and requires no knowledge of the specific analytes of interest, as in selective ion monitoring (SIM), and does not restrict the mass spectral data used, as in both SIM and total ion current (TIC) methods. Significantly, the methodology allows for the classification of data with low resolution in the chromatographic dimension because of the added selectivity from the complete mass spectral dimension. This allows for the successful classification of data over significantly decreased chromatographic separation times, since high-speed separations can be employed. The methodology is demonstrated through the analysis of a set of four differing gasoline samples that serve as model complex samples. For comparison, the gasoline samples are analyzed by GC-MS over both 10-min and 10-s separation times. The successfully classified 10-min GC-MS TIC data served as the benchmark analysis to compare to the 10-s data. When only alignment and feature selection was applied to the 10-s gasoline separations using GC-MS TIC data, PCA failed. PCA was successful for 10-s gasoline separations when the methodology was applied with all the m/z information. With ANOVA feature selection, chromatographic regions with Fisher ratios greater than 1500 were retained in a new matrix and subjected to PCA yielding successful classification for the 10-s separations.  相似文献   
75.
An ion chromatographic (IC) method for the determination of oxalate in plasma was developed. The method exploits a rapid and simple sample preparation step that substantially reduces the plasma chloride level to facilitate the oxalate determination. The chloride is removed as silver chloride by using a cation-exchange resin in the silver cation form. The dependence on chloride concentration and pH was evaluated. The oxalate recovery in plasma samples was found to be 93 ± 18% (n=4 trials) according to a standard addition study. A comparison of the IC method with an enzymatic method indicated that both methods measure the same oxalate concentration over the range examined, 5–300 μM. Furthermore, the comparison involved a correlation study that allowed cross-validation of the two methods, suggesting that neither is adversely affected by interferences. The detection limit of the IC method was 0.5 μM or 4.4 ng oxalate.  相似文献   
76.
For l, an -triangulation F of a planar domain is such that,for every T F, there holds 1 RT/2rT , where RT (resp. rT)denotes the radius of the circumscribed (resp. inscribed) circleof the triangle T. When T is varying in F the centre of itsinscribed circle is varying in a compact interior to T and itsorthogonal projections on the sides are varying in compact intervalsinterior to these sides. Precise results are given about thesizes of these compacts and are used for the computation oferror constants in the problem of Hermite interpolation by Powell-Sabinquadratic finite elements, bringing to the fore their dependenceon the parameter .  相似文献   
77.
Quigley WW  Ecker ST  Vahey PG  Synovec RE 《Talanta》1999,50(3):569-576
The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m(-1), was obtained for resorcinol, at a retention factor of k'=4.88 (retention time of 9.55 min at 1 ml min(-1) for a 25 cmx4.6 mm i.d. column, packed with 5 mum diameter particles with the cyano propyl stationary phase). A separation via reversed phase liquid chromatography (RP-LC) with a 100% water mobile phase of six phenols and related compounds was compared to a separation of the same compounds by traditional RP-LC, using octadecylsilane (ODS), i.e. C18, bound to silica and an aqueous mobile phase modified with acetonitrile. Nearly identical analysis time was achieved for the separation of six phenols and related compounds using the cyano propyl stationary phase with a 100% water mobile phase, as compared to traditional RP-LC requiring a relatively large fraction of organic solvent modifier in the mobile phase (25% acetonitrile:75% water). Additional understanding of the retention mechanism with the 100% water mobile phase was obtained by relating measured retention factors of aliphatic alcohols, phenols and related compounds, and chlorinated hydrocarbons to their octanol:water partition coefficients. The retention mechanism is found to be consistent with a RP-LC mechanism coupled with an additional retention effect due to residual hydroxyl groups on the cyano propyl stationary phase. Advantages due to a 100% water mobile phase for the chemical analysis of alcohol mixtures and chlorinated hydrocarbons are reported. By placing an absorbance detector in-series and preceding a novel drop interface to a flame ionization detector (FID), selective detection of a separated mixture of phenols and related compounds and aliphatic alcohols is achieved. The compound class of aliphatic alcohols is selectively and sensitively detected by the drop interface/FID, and the phenols and related compounds are selectively and sensitively detected by absorbance detection at 200 nm. The separation and detection of chlorinated hydrocarbons in a water sample matrix further illustrated the advantages of this methodology. The sensitivity and selectivity of the FID signal for the chlorinated hydrocarbons are significantly better than absorbance detection, even at 200 nm. This methodology is well suited to continuous and automated monitoring of water samples. The applicability of samples initially in an organic solvent matrix is explored, since an organic sample matrix may effect retention and efficiency. Separations in acetonitrile and isopropyl alcohol sample matrices compared well to separations with a water sample matrix.  相似文献   
78.
肉苁蓉 Cistanche Salsa(C.A.Mey.)G.Beak 是列当科 Orobanchaceae 植物肉苁蓉的肉质茎;又名大芸,纵蓉。它分布在北疆地区荒漠戈壁地带,有益肾壮阳,延年益寿等功能,故有“沙漠人参”之称。肉苁蓉是一种常用的中药,新疆地区资源丰富,其精油化学成分在国内外未见报道。为了整理和发掘祖国医药学宝库,我们对其化学成分进行了研究。  相似文献   
79.
Young TE  Ecker ST  Synovec RE  Hawley NT  Lomber JP  Wai CM 《Talanta》1998,45(6):1189-1199
Reversed phase high-performance liquid chromatography (RP-HPLC) is demonstrated for hydrophobic analytes such as aromatic hydrocarbons on a chemically bonded stationary phase and a mobile phase consisting of only water. Reversed phase liquid chromatography separations using a water-only mobile phase has been termed WRP-LC for water-only reversed phase LC. Reasonable capacity factors are achieved through the use of a non-porous silica substrate resulting in a chromatographic phase volume ratio much lower than usually found in RP-HPLC. Two types of bonded WRP-LC columns have been developed and applied. A brush phase was synthesized from an organochlorosilane. The other phase, synthesized from an organodichlorosilane, is termed a branch phase and results in a polymeric structure of greater thickness than the brush phase. A baseline separation of a mixture containing benzaldehyde, benzene, toluene, and ethyl benzene in less than 5 min is demonstrated using a water mobile phase with 12 000 plates generated for the unretained benzaldehyde peak. The theoretically predicted minimum reduced plate height is also shown to be approached for the unretained analyte using the brush phase. As an application, subcritical water extraction (SWE) at 200°C is combined with WRP-LC. This combination allows for the extraction of organic compounds from solid matrices immediately followed by liquid chromatographic separation of those extracted compounds all using a solvent of 100% water. We demonstrate SWE/WRP-LC by spiking benzene, ethyl benzene, and naphthalene onto sand then extracting the analytes with SWE followed by chromatographic separation on a WRP column. A sand sample contaminated with gasoline was also analyzed using SWE/WRP-LC. This extraction process also provides kinetic information about the rate of analyte extraction from the sand matrix. Under the conditions employed, analytes were extracted at different rates, providing additional selectivity in addition to the WRP-LC separation.  相似文献   
80.
High-speed temperature programming is implemented via the direct resistive heating of the separation column (2.3m MXT-5 Silicosteel column with a 180 microm I.D. and a 0.4 microm 5% phenyl/95% dimethyl polysiloxane film). Resistive temperature programming was coupled with synchronized dual-valve injection (with an injection pulse width of 2 ms), producing a complete high-speed gas chromatography (GC) system. A comparison of isothermal and temperature programmed separations of seven n-alkanes (C(6) and C(8)-C(13)) shows a substantial improvement of peak width and peak capacity with temperature programming. The system was further implemented in separations of a mixture of analytes from various chemical classes. Separations of the n-alkane mixture using three different temperature programming rates are reported. A temperature programming rate as high as 240 degrees C/s is demonstrated. The method for determination of temperature programming rate, based on isothermal data, is discussed. The high-speed resistive column heating temperature programming resulted in highly reproducible separations. The highest rate of temperature programming (240 degrees C/s) resulted in retention time and peak width RSD, on average, of 0.5 and 1.4%, respectively, for the n-alkane mixture. This high level of precision was achieved with peak widths-at-half-height ranging from 13 to 36 ms, and retention times ranging from 147 to 444 ms (for n-hexane to n-tridecane).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号