首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   4篇
化学   36篇
  2018年   2篇
  2016年   2篇
  2015年   4篇
  2014年   1篇
  2013年   3篇
  2012年   3篇
  2011年   5篇
  2010年   3篇
  2009年   3篇
  2008年   1篇
  2007年   5篇
  2005年   1篇
  2004年   3篇
排序方式: 共有36条查询结果,搜索用时 15 毫秒
31.
Shahrokhian S  Rastgar S 《The Analyst》2012,137(11):2706-2715
Mixtures of gold-platinum nanoparticles (Au-PtNPs) are fabricated consecutively on a multi-walled carbon nanotubes (MWNT) coated glassy carbon electrode (GCE) by the electrodeposition method. The surface morphology and nature of the hybrid film (Au-PtNPs/MWCNT) deposited on glassy carbon electrodes is characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. The modified electrode is used as a new and sensitive electrochemical sensor for the voltammetric determination of cefotaxime (CFX). The electrochemical behavior of CFX is investigated on the surface of the modified electrode using linear sweep voltammetry (LSV). The results of voltammetric studies exhibited a considerable improvement in the oxidation peak current of CFX compared to glassy carbon electrodes individually coated with MWCNT or Au-PtNPs. Under the optimized conditions, the modified electrode showed a wide linear dynamic range of 0.004-10.0 μM with a detection limit of 1.0 nM for the voltammetric determination of CFX. The modified electrode was successfully applied for the accurate determination of trace amounts of CFX in pharmaceutical and clinical preparations.  相似文献   
32.
The electrochemical oxidation of thiocytosine on the surface of carbon-paste electrode modified with Schiff base (salophen derivatives) complexes of cobalt is studied. The effect of the substituents in the structure of salophen on the catalytic property of the modified electrode is investigated by using cyclic and differential pulse voltammetry. Cobalt (II)-5-nitrosalophen, because of its electrophilic functional groups, leads to a considerable enhancement in the catalytic activity, sensitivity (peak current), and a marked increase in the anodic potential of the modified electrode. The differential pulse voltammetry is applied as a very sensitive method for the detection of thiocytosine. The linear dynamic range was between 1 × 10−3 to 4 × 10−6 M with a slope of 0.0168 μA/μM, and the detection limit was 1 × 10−6 M. The modified electrode is successfully applied for the voltammetric detection of thiocytosine in human synthetic serum sample and also pharmaceutical preparations. A linear range from 1 × 10−3 to 1 × 10−5 M with a slope of 0.0175 μA/μM is resulted for the standard addition of thiocytosine spiked to the buffered human serum, which is differing from the curve in buffer solution about 4%. The electrode has a very good reproducibility (relative standard deviation for the slope of the calibration curve is less than 3.5% based on six determinations in a month), high stability in its voltammetric response and low detection limit for thiocytosine, and high electrochemical sensitivity with respect to other biological thiols such as cysteine.  相似文献   
33.
A carbon-paste electrode chemically modified with a Schiff-base complex of cobalt (cobalt(II)-4-chlorosalophen, CoClSal) is utilized to investigate the voltammetric response of propylthiouracil (PTU). The mechanism of electrocatalytic oxidation of the compound is investigated by means of cyclic voltammetric studies applying various pHs to the buffered solutions. The modified electrode exhibits effective catalytic properties that lower the anodic overpotential and enhance the rate of electron transfer for the electrochemical oxidation of PTU. The results of the cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques showed that the modified electrode exhibits good selectivity for discriminating between the anodic wave of PTU and some biological thiols (e.g. cysteine) which may be present in human serum samples. DPV is used as a very sensitive electroanalytical method for the detection of trace amounts of PTU in pharmaceutical and clinical preparations. The results showed that the anodic peak current for the analyte in DPV varies linearly with the concentration of PTU in the range of 7.5 × 10−6 to 7.5 × 10−4 M (RSD for the slope of calibration curve <4%, n = 6).  相似文献   
34.
A composition of multiwalled carbon nanotube (MWCNT), Nafion and cobalt(II)‐5‐nitrosalophen (CoNSal) is applied for the modification of carbon‐paste electrode (CPE). The pretreated MWCNT is well dispersed in the alcoholic solution of Nafion under the ultrasonic agitation, and the resulted suspension is used as modifier (with 10% w/w) in the matrix of the paste electrode. The prepared electrode further modified by addition of 3 wt% of CoNSal. The resulted modified electrode is used as a sensitive voltammetric sensor for simultaneous determination of uric acid (UA) and ascorbic acid (AA). The electrode showed efficient electrocatalytic activity in lowering the anodic overpotentials and enhancement of the anodic currents. This electrode is able to completely resolve the voltammetric response of UA and AA. The effects of potential sweep rate and pH of the buffer solution on the response of the electrode, toward UA and AA, and the peak resolution is thoroughly investigated by cyclic and differential pulse voltammetry (CV and DPV). The best peak resolution for these compounds using the modified electrode is obtained in solutions with pH 4. The ΔEp for UA and AA in these methods is about 315 mV, which is considerably better than previous reports for these compounds. A linear dynamic range of 1×10?7 to 1×10?4 M with a detection limit of 6×10?8 M is resulted for UA in buffered solutions with pH 4.0. The voltammetric response characteristics for AA are obtained as, the linear range of 5×10?7 to 1×10?4 M with the detection limit of 1×10?7 M. The voltammetric detection system was very stable and the reproducibility of the electrode response, based on the six measurements during one month, was less than 3.5% for the slope of the calibration curves of UA and AA. The prepared modified electrode is successfully applied for the determination of AA and UA in mixture samples and reasonable accuracies are resulted.  相似文献   
35.
The potentiometric response characteristics with respect to salicylate anion of several membrane electrodes based on iron(III) tetraphenylporphyrin chloride (FeTPPCl) and derivatives with electrophilic and nucleophilic substituents, incorporated into plasticized polyvinylchloride (PVC) membranes were investigated. Complexes tetraphenyl porphyrin iron(III) chloride (FeTPPCl; A), tetrakis (4-methoxyphenyl) porphyrin iron(III) chloride (Fe(TOCH3PP)Cl; B), tetrakis (2,6-dichlorophenyl) porphyrin iron(III) chloride (Fe(TDClPP)Cl; C), tetrakis (4-nitrophenyl) porphyrin iron(III) chloride (Fe(TNO2PP)Cl; D), and tetrakis (pentafluorophenyl) porphyrin iron(III) chloride (Fe(TPFPP)Cl; E) were used as anion carriers in the membrane electrodes. The sensitivity, working range, detection limit, response mechanism, and selectivity of the membrane sensor toward interference shows a considerable dependence on the type of carrier substituent and the pH value of the sample solution. Potentiometric investigations in solutions of various pH show that the carrier complex containing fluoro substituents (E), which have very strong electron-accepting properties and a high ability to form hydrogen bonds, is capable of serving as a positively charged ionophore. Some other ionophores are capable of serving as both charged and neutral carriers under different conditions. The electrodes prepared in this work show super-Nernstian slopes with respect to salicylate concentration, which tend to a Nernstian response (slope near to -59 mV decade-1) upon an increase of the pH of the test solution. The results of UV/Vis absorption spectroscopy are used for interpretation of the formation of an oxene complex between salicylate and iron porphyrins.  相似文献   
36.
The electrochemical oxidation of sumatriptan on the surface of carbon paste electrode modified with multi-walled carbon nanotube and cobalt methyl-salophen complex is studied by using cyclic voltammetry and polarization studies. The results indicate that the drug is irreversibly oxidized in a one electron oxidation mechanism. It was found that the peak potential shifted negatively with increasing pH, confirms that H(+) participate in the oxidation process. The electrode is shown to be very effective for the detection of sumatriptan in the presence of other biological reductant compounds. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of sumatriptan, ascorbic acid and uric acid, which makes it suitable for the simultaneous detection of sumatriptan in the presence of these compounds in clinical and pharmaceutical preparations. It can be concluded that multi-walled carbon nanotube and Shiff base complex have synergic effect on electroacatalytic oxidation of sumatriptan. A linear range of 1-1000μM and detection limit of 0.3μM was obtained for sumatriptan from DPV measurements using this electrode in 0.1M acetate buffered solution of pH 5.0. The electrode has been applied successfully for the determination of sumatriptan in synthetic serum and commercial tablets.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号