首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   97篇
  免费   9篇
化学   92篇
晶体学   1篇
力学   1篇
数学   5篇
物理学   7篇
  2024年   1篇
  2023年   2篇
  2022年   4篇
  2021年   6篇
  2020年   7篇
  2019年   6篇
  2018年   5篇
  2017年   1篇
  2016年   9篇
  2015年   5篇
  2014年   7篇
  2013年   9篇
  2012年   11篇
  2011年   6篇
  2010年   3篇
  2009年   2篇
  2008年   6篇
  2007年   9篇
  2006年   1篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2002年   1篇
排序方式: 共有106条查询结果,搜索用时 15 毫秒
41.

Abstract  

Two novel ferrocenyl substituted N-acetyl-2-pyrazolines, N-acetyl-3-(2-furyl)-5-ferrocenyl-2-pyrazoline (3) and N-acetyl-3-(2-thienyl)-5-ferrocenyl-2-pyrazoline (4), have been synthesized and characterized by FTIR, 1H-NMR, 13C-NMR techniques, elemental analysis and X-ray structure analysis. Thermal properties of these compounds have been determined by TGA, DTA and DSC analysis. Compound 3 (C19H18N2O2Fe) crystallizes in the monoclinic space group P21/c and Z = 4, with a = 8.6970(4) ?, b = 18.4725(9) ?, c = 11.0041(5) ?, β = 110.942(3)°. Compound 4 (C19H18N2OSFe) crystallizes in the orthorhombic space group Fdd2 and Z = 16, with a = 84.242(2) ?, b = 13.5416(5) ?, c = 5.9405(2) ?, β = 90°. In terms of crystal packing, each compound shows different molecular arrangement, which are stabilized by C–H···O intermolecular weak hydrogen bonds, and/or C–H···π interactions.  相似文献   
42.
43.
Photoactive allyl ammonium salt (BPEA) containing benzophenone moiety in the structure was synthesized and characterized. Its capability to act as a self-initiating addition fragmentation agent in the photoinitiated cationic polymerization of oxiranes such as cyclohexene oxide and vinyl monomers such as butylvinyl ether was investigated. These monomers turned out to be polymerizable in the presence of BPEA provided free radicals are generated photochemically at λ>300 nm by hydrogen abstraction of excited benzophenone moiety. Accordingly, a free radical adds to the carbon-carbon double bond of a ground state BPEA and fragmentation of the adduct radical results in the formation of reactive ammonium radical cation which is essentially responsible for the initiation.  相似文献   
44.
A new type of fluorescent chemosensor based on tethered hexa-borondipyrromethene cyclotriphosphazene platform (HBTC) linked via triazole groups was designed and synthesized. Its sensing behavior toward metal ions was investigated by ultraviolet-visible and fluorescence spectroscopies. Addition of a Fe2+ ion to a tetrahydrofuran solution of HBTC gave a visual color change as well as a significantly quenched fluorescence emission, while other tested 19 metal ions induced no color or spectral changes. This compound was found to be highly selective and sensitive for Fe2+ with a low limit of detection (2.03 μM) which is, to the best of our knowledge, the superior than the previously studied chemosensors for Fe2+.
Graphical Abstract ?
  相似文献   
45.
DNA hypermethylation is an epigenetic alteration and a promising biomarker for early prostate cancer detection. Simple, sensitive, easy to handle and rapid detection methodologies are imperative for point of care diagnostics especially for cancer. Herein, we describe for the first time a regenerable and compatible electrochemical biosensor for detection of Glutathione S‐Transferase P‐1 (GSTP‐1) gene hypermethylation related to prostate cancer via DNA hybridization onto the disposable Carbon and Multi Walled Carbon Nanotubes (MWCNT) Screen Printed Electrodes (SPEs). In the study, capture probes were adsorbed onto the SPEs by simple passive adsorption and then hybridization was achieved by sending the complementary target onto the probe‐modified electrodes. The selectivity of the biosensor was proved by control studies. Differential Pulse Voltammetry (DPV) technique was used to detect hybridization via guanine oxidation signals changes. The total time of the optimized method was nearly 1h, measurements took for less than 1 min, and the biosensor response was stable up to 40 days of storage period at 4 °C. The main advantages of the biosensor are very low detection limit (picomolar range) and capability of reusing the biosensor for at least 3 times after very simple regeneration process that is a unique property to reduce the cost of the assay. In addition, this is the first study that demonstrates the detection of GSTP‐1 hypermethylation electrochemically by using SPEs in order to create point of care diagnostics. The optimum parameters for the biosensor, as well as its future prospects to enhance the performance of DNA biosensors were also presented.  相似文献   
46.
Determination of copper (Cu), zinc (Zn) and manganese (Mn) micronutrients in soil samples have been studied for an efficient fertiliser application. Plant-available micronutrients of soils were extracted with DTPA extraction procedure, then differential pulse stripping voltammetry (DPSV) and square wave stripping voltammetry (SWSV) methods were performed with inexpensive and disposable pencil graphite electrode for determination of Cu(II), Zn(II) and Mn(II). Parameters such as deposition potential, deposition time, pH and concentration of the supporting electrolyte were optimised for these ions. Under optimised conditions, the limits of detection were found as 0.01 mg L?1 for Cu(II) and 0.02 mg L?1 for Zn(II) and 0.25 mg L?1 for Mn(II). Relative standard deviation (%RSD) was 6.80, 8.86 and 3.29 for Cu(II), Zn(II) and Mn(II), respectively. The experimental study was conducted using a flame atomic absorption spectroscopy. The described stripping voltammetry methods were successfully applied for the determination of Mn(II), Cu(II) and Zn(II) in soil samples.  相似文献   
47.
48.
Four new 2,1,3‐benzooxadiazole‐based donor–acceptor conjugated polymers, namely poly{9‐(9‐heptadecanyl)‐9H‐carbazole‐alt‐5,6‐bis(octyloxy)‐4,7‐di(selenophen‐2‐yl)benzo[c][1,2,5]oxadiazole)}(PSBSC), poly{9‐(9‐heptadecanyl)‐9H‐carbazole‐alt‐5,6‐bis(octyloxy)‐4,7‐di(furan‐2‐yl)benzo[c][1,2,5]oxadiazole)}(PFBFC), poly{9,9‐dioctyl‐9H‐fluorene‐alt‐5,6‐bis(octyloxy)‐4,7‐di(selenophen‐2‐yl)benzo[c][1,2,5]oxadiazole)}(PSBSFL), and poly{9,9‐dioctyl‐9H‐fluorene‐alt‐5,6‐bis(octyloxy)‐4,7‐di(furan‐2‐yl)benzo[c][1,2,5]oxadiazole)}(PFBFFL), were synthesized via Stille polycondensation reaction. All polymers were found to be soluble in common organic solvents such as chloroform, tetrahydrofuran, and chlorobenzene. Their structures were verified by 1H‐NMR and the molecular weights were determined by gel permeation chromatography (GPC). The polymer films exhibited broad absorption bands. Among all polymers, photovoltaic cells based on the device structure of ITO/PEDOT:PSS/PSBSC:PC71BM(1:3, w/w)/LiF/Al revealed an open‐circuit voltage of 0.62 V, a short circuit current of 7.63 mA cm?2 and a power conversion efficiency of 1.89%. This work demonstrates a good example for tuning absorption range, energy level, and photovoltaic properties of the polymers with different spacers and donor units can offer a simple and effective method to improve the efficiency of PSCs. © 2016 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2016 , 54, 2459–2467  相似文献   
49.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has rarely been used in the field of therapeutic drug monitoring, partly because of the complexity of the ionization processes between the compounds to be quantified and the many MALDI matrices available. The development of a viable MALDI-MS method that meets regulatory guidelines for bioanalytical method validation requires prior knowledge of the suitability of (i) the MALDI matrix with the analyte class and properties for ionization, (ii) the crystallization properties of the MALDI matrix with automation features, and (iii) the MS instrumentation used to achieve sensitive and specific measurements in order to determine low pharmacological drug concentrations in biological matrices. In the present hybrid article/white paper, we review the developments required for the establishment of MALDI-MS assays for the quantification of drugs in tissues and plasma, illustrated with concrete results for the different steps. We summarize the necessary parameters that need to be controlled for the successful development of fully validated MALDI-MS methods according to regulatory authorities, as well as currently unsolved problems and promising ways to address them. Finally, we propose an expert opinion on future perspectives and needs in order to establish MALDI-MS as a universal method for therapeutic drug monitoring.  相似文献   
50.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号