This paper studies the concept of controllability for infinite-dimensional linear control systems in Banach spaces. First,
we prove that the set of admissible control operators for the semigroup generator is unchanged if we perturb the generator
by the Desch–Schappacher perturbations. Second we show that exact controllability is not changed by such perturbations. 相似文献
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations. 相似文献
The treatment of the non-linear isotherm in chromatography by one of the authors [1] is extended to other cases of practical interest. The original paper dealt with the case of an initially thin zone resulting in a Poisson distribution the asymmetry of which is a function of the plate number and the non-linearity constant. The present work shows that the same relations apply to initially thick zones and to the cases of washing and deposition leading to simple relations for breakthrough curves. For significantly non-linear isotherms other quasi-Gaussian distributions can give a better fit. 相似文献
Square-planar copper(II) and nickel(II) derivatives of the cis-dithiolate N(2)S(2) ligand bis(N,N'-2-mercapto-2-methylpropyl)-1,5-diazocyclooctane, (bme*daco)M, nucleate four Cu(I)Cl moieties, forming M(II)(2)Cu(I)(4)S(4) clusters with unusual triply bridging thiolates, mu(3)-SR, in the topological form of adamantane. As determined by X-ray crystallography, the (bme*daco)M (M = Cu or Ni) metallothiolate serves as a bidentate ligand that bridges four Cu(I) ions, utilizing all lone pairs on sulfurs. Further characterization by electrochemical and electronic spectral measurements suggests greater electron delocalization in the all-copper complex as compared to the NiCu heterometallic complex. Mass spectral data imply that the mixed-metal Ni(II)(2)Cu(I)(4)S(4) is more stable toward CuCl loss than Cu(II)(2)Cu(I)(4)S(4), a result that is corroborated by extraction of Cu(I) by 1,2-bis(diphenylphosphino)ethane in the latter but not the former. 相似文献
A series of Bcl-x(L)/Bak antagonists, based on a terephthalamide scaffold, was designed to mimic the alpha-helical region of the Bak peptide. These molecules showed favorable in vitro activities in disrupting the Bcl-x(L)/Bak BH3 domain complex (terephthalamides 9 and 26, K(i) = 0.78 +/- 0.07 and 1.85 +/- 0.32 microM, respectively). Extensive structure-affinity studies demonstrated a correlation between the ability of terephthalamide derivatives to disrupt Bcl-x(L)/Bak complex formation and the size of variable side chains on these molecules. Treatment of human HEK293 cells with the terephthalamide derivative 26 resulted in disruption of the Bcl-x(L)/Bax interaction in whole cells with an IC(50) of 35.0 microM. Computational docking simulations and NMR experiments suggested that the binding cleft for the BH3 domain of the Bak peptide on the surface of Bcl-x(L) is the target area for these synthetic inhibitors. 相似文献
The theory of composite chromatographic columns has been re-examined and general equations relating their efficiency to those of individual columns were derived. The derivations were based on elementary principles without reference to the principle of variance additivity. Derived also, were general equations for the efficiency of columns with continuously varying diameters, HETP and other properties from which formulae for special cases of practical interest were deduced. An example comparing the efficiencies of two columns, one conical and the other composite was given. The calculations show clearly that the conical column is superior in efficiency for the same total length and total retention volume. 相似文献
In the applications of single-walled carbon nanotubes (SWNTs), it is extremely important to separate semiconducting and metallic SWNTs. Although several methods have been reported for the separation, only low yields have been achieved at great expense. We show a separation method involving a dispersion-centrifugation process in a tetrahydrofuran solution of amine, which makes metallic SWNTs highly concentrated to 87% in a simple way. 相似文献
A totally automated and reliable high-performance liquid chromatographic method is described for the routine determination of free catecholamines (norepinephrine, epinephrine and dopamine) in urine. The catecholamines were isolated from urine samples using small alumina columns. A standard automated method for pH adjustment of urine before the extraction step has been developed. The extraction was performed on an ASPEC (Automatic Sample Preparation with Extraction Columns, Gilson). The eluate was collected in a separate tube and then automatically injected into the chromatographic column. The catecholamines were separated by reversed-phase ion-pair liquid chromatography and quantified by fluorescence detection. No manual intervention was required during the extraction and separation procedure. One sample may be run every 15 min, ca. 96 samples in 24 h. Analytical recoveries for all three catecholamines are 63-87%, and the detection limits are 0.01, 0.01, and 0.03 microM for norepinephrine, epinephrine and dopamine, respectively, which is highly satisfactory for urine. Day-to-day coefficients of variation were less than 10%. 相似文献
Permselective modifier films are very important in preparing highly sensitive electrochemical sensors. In this work, for the first time, the behavior of gold and glassy carbon electrodes coated with biocompatible zein film as a permselective membrane for the electrochemical detection of various compounds has been investigated. For this purpose, several electroactive cationic (methylene blue, brilliant green, and thionine) and anionic (potassium ferricyanide, alizarin red S, and riboflavin-5’-phosphate) compounds have been used as model. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) showed that zein membranes prepared from casting solution containing 1% zein in ethanol/water have porous structures with high nanometric roughness. The capacitance values of electrical double layers of electrodes modified with zein film were very high for hydrophilic ions in comparison with hydrophobic ions. Point of zero charge pH (pHpzc) of zein membrane was 4.8. The results of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) as well as pHpzc study indicated that zein permselective membrane acts as ion exchanger film for selected cationic compounds with fast electrochemical kinetics responses in aqueous solution (pH=7). This behavior was confirmed by circulating solutions containing model compounds from homemade continuous cell equipped with polyamide membranes modified with zein film.
A novel membrane sensor for selective monitoring of iodide, consisting of a triiodide‐ketoconazole ion pair complex dispersed in a PVC matrix, plasticized with a mixture of 2‐nitrophenyl octyl ether and dioctylphtalate with unique selectivity toward iodide ions, is described. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The optimized membrane demonstrates a near‐Nernstian response for iodide ions over a wide linear range from 1.0 × 10?2 to 1.0 × 10?5 M, at 25 ± 1 °C. The electrode could be used over a wide pH range 3–10 and has the advantages of high selectivity, fast response time and good lifetime (over 4 months). It was successfully used as indicator electrode in potentiometric titrations and direct potentiometric assay of iodide ions. 相似文献