首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   37篇
  免费   1篇
化学   9篇
晶体学   1篇
力学   3篇
数学   1篇
物理学   24篇
  2021年   1篇
  2016年   1篇
  2015年   1篇
  2014年   3篇
  2013年   1篇
  2012年   1篇
  2011年   2篇
  2010年   2篇
  2008年   5篇
  2007年   1篇
  2006年   4篇
  2005年   1篇
  2004年   4篇
  2003年   1篇
  2002年   1篇
  1999年   1篇
  1998年   3篇
  1997年   2篇
  1985年   1篇
  1983年   1篇
  1982年   1篇
排序方式: 共有38条查询结果,搜索用时 78 毫秒
11.
12.
Six samples of polypropylene produced by Montepolimeri were carefully characterized in dilute solution and studied, with a capillary extrusion rheometer, in large ranges of shear and temperature. The extrudate swelling behaviour is found to be regular as far as its shear stress and temperature dependence is concerned, but the influence of molecular weight is abnormal. With increasing molecular weight the amount of elastic recovery (as measured by the extrudate swell) decreases markedly and the shear modulusG (obtained from the data by making use of simplifying assumptions) appears to be an increasing function ofM w at all the shear stress investigated. No similar results appear to be reported in the literature.Presented in part at the VIIIth Intern. Congress on Rheology, Naples, September 1–5, 1980.  相似文献   
13.
The elongational behaviour of polyethylene samples having different molecular structure has been tested. Elongational viscosity measurements have been carried out using the isothermal melt spinning technique. The extensional behaviour of the different samples is analysed as a function of total strain. The effect of long-chain branching on elongational viscosities is described. A comparison is presented between elongational viscosity and melt strength data.Some of the results reported here were presented at the VIIIth International Congress on Rheology, Naples, September 1–5, 1980, cf. [16].  相似文献   
14.
Pugnat  P.  Ballou  R.  Schott  M.  Husek  T.  Sulc  M.  Deferne  G.  Duvillaret  L.  Finger  M.  Finger  M.  Flekova  L.  Hosek  J.  Jary  V.  Jost  R.  Kral  M.  Kunc  S.  Macuchova  K.  Meissner  K. A.  Morville  J.  Romanini  D.  Siemko  A.  Slunecka  M.  Vitrant  G.  Zicha  J. 《The European Physical Journal C - Particles and Fields》2014,74(8):1-7
Recent Planck measurements show some CMB anomalies on large angular scales, which confirms the early observations by WMAP. We show that an inflationary model, in which before the slow-roll inflation the Universe is in a superinflationary phase, can generate a large-scale cutoff in the primordial power spectrum, which may account for not only the power suppression on large angular scales, but also a large dipole power asymmetry in the CMB. We discuss an implementation of our model in string theory.  相似文献   
15.
A new technique of cavity enhanced absorption spectroscopy is described. Molecular absorption spectra are obtained by recording the transmission maxima of the successive TEMoo resonances of a high-finesse optical cavity when a Distributed Feedback Diode Laser is tuned across them. A noisy cavity output is usually observed in such a measurement since the resonances are spectrally narrower than the laser. We show that a folded (V-shaped) cavity can be used to obtain selective optical feedback from the intracavity field which builds up at resonance. This induces laser linewidth reduction and frequency locking. The linewidth narrowing eliminates the noisy cavity output, and allows measuring the maximum mode transmissions accurately. The frequency locking permits the laser to scan stepwise through the successive cavity modes. Frequency tuning is thus tightly optimized for cavity mode injection. Our setup for this technique of Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) includes a 50 cm folded cavity with finesse ∼20 000 (ringdown time ∼20 μs) and allows recording spectra of up to 200 cavity modes (2 cm−1) using 100 ms laser scans. We obtain a noise equivalent absorption coefficient of ∼5×10−10 cm−1 for 1 s averaging over scans, with a dynamic range of four orders of magnitude.  相似文献   
16.
Computable error bounds for pointwise derivatives of a Neumann problem   总被引:1,自引:0,他引:1  
In this paper we discuss the recovery of derivatives and thecomputation of rigorous and useful upper bounds for the pointwiseerror in the recovered derivatives, for finite element approximationsof the Laplace equation with Neumann boundary conditions, especiallyat points close to or on a smooth, curved boundary. We analyzethe dipole image technique for the case of curved boundaries,and show how to compute reliable recovered derivatives and errorbounds even in the limiting case of points lying on the curvedboundary. Numerical experiments show reasonably tight errorbounds for points both close to and away from a curved boundary.  相似文献   
17.
This Communication describes the chemo- and site-selective coupling of cell type-specific targeting peptides to a virus capsid containing aminophenylalanine residues.  相似文献   
18.
MRI contrast agents providing very high relaxivity values can be obtained through the attachment of multiple gadolinium(III) complexes to the interior surfaces of genome-free viral capsids. In previous studies, the contrast enhancement was predicted to depend on the rigidity of the linker attaching the MRI agents to the protein surface. To test this hypothesis, a new set of Gd-hydroxypyridonate based MRI agents was prepared and attached to genetically introduced cysteine residues through flexible and rigid linkers. Greater contrast enhancements were seen for MRI agents that were attached via rigid linkers, validating the design concept and outlining a path for future improvements of nanoscale MRI contrast agents.  相似文献   
19.
We report on the first application of Optical Feedback-Cavity Enhanced Absorption Spectroscopy to formaldehyde trace gas analysis at mid-infrared wavelengths. A continuous-wave room-temperature, distributed-feedback quantum cascade laser emitting around 1,769 cm?1 has been successfully coupled to an optical cavity with finesse 10,000 in an OF-CEAS spectrometer operating on the ν2 fundamental absorption band of formaldehyde. This compact setup (easily transportable) is able to monitor H2CO at ambient concentrations within few seconds, presently limited by the sample exchange rate. The minimum detectable absorption is 1.6 × 10?9 cm?1 for a single laser scan (100 ms, 100 data points), with a detectable H2CO mixing ratio of 60 pptv at 10 Hz. The corresponding detection limit at 1 Hz is 5 × 10?10 cm?1, with a normalized figure of merit of 5 × 10?11cm $^{-1}/\sqrt{\rm Hz}$ (100 data points recorded in each spectrum taken at 10 Hz rate). A preliminary Allan variance analysis shows white noise averaging down to a minimum detection limit of 5 pptv at an optimal integration time of 10 s, which is significantly better than previous results based on multi-pass or cavity-enhanced tunable QCL absorption spectroscopy.  相似文献   
20.
We present a scheme of optical feedback cavity-enhanced absorption spectroscopy (OF-CEAS) including a fast optical switch to produce cavity ringdown spectra (OF-CRDS) simultaneously. This also works as a dynamically adjustable variable attenuator allowing to compensate for reduced signal levels in correspondence with absorption lines. For this, an acousto-optic deflector is used in a double-pass configuration to eliminate the single-pass frequency shift, which is incompatible with optical feedback. This is probably the most effective device providing the required fast response and the high extinction ratio necessary to perform clean ringdown measurements. The resulting direct comparison of OF-CEAS and OF-CRDS shows that these produce almost equivalent spectral data, with 0.3 % maximal difference at the top of an absorption line having a signal-to-noise ratio (S/N) of 3,300. OF-CEAS is largely winning on the short-term noise level while OF-CRDS appears to be more immune from interference fringes, delivering cleaner spectra after longer averaging.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号