排序方式: 共有40条查询结果,搜索用时 281 毫秒
31.
Dolashka-Angelova P Beck A Dolashki A Stevanovic S Beltramini M Salvato B Hristova R Velkova L Voelter W 《Micron (Oxford, England : 1993)》2004,35(1-2):101-104
Using Zn2+ ions as new method, several FUs have been isolated from molluscan Hc Rapana venosa without formation of non-functional proteolytic side products. N-terminal sequences of these fragments in comparison with FUS from other gastropodan Hcs show a very high degree of structural identity. Four Fus, purified from enzyme-treated structural subunits RvH1 and RvH2 (RvH1-a, RvH1-f, RvH2-a and RvH2-e) show identical N-terminal sequences compared to fragments isolated after treatment with Zn2+ ions. However, in some cases trypsin cleaves RvH chains at different positions if compared to the Zn2+ treatment. To analyze the oligosaccharide composition of two FUS from the first structural subunit of Rapana Hc, RvH1-a and RvH1-f, several techniques were applied: capillary electrophoresis, MALDI-MS, ESI-MS in combination with glycosidase digestions. On basis of these results and the determined amino acid sequence two N-linkage sites were identified in the FU RvH1-a, but only one in the FU RvH1-f. 相似文献
32.
Pavlina Jordanova Zdeněk Fabián Philipp Hermann Luboš Střelec Andrés Rivera Stéphane Girard Sebastián Torres Milan Stehlík 《Extremes》2016,19(4):591-626
We describe a novel method of heavy tails estimation based on transformed score (t-score). Based on a new score moment method we derive the t-Hill estimator, which estimates the extreme value index of a distribution function with regularly varying tail. t-Hill estimator is distribution sensitive, thus it differs in e.g. Pareto and log-gamma case. Here, we study both forms of the estimator, i.e. t-Hill and t-lgHill. For both estimators we prove weak consistency in moving average settings as well as the asymptotic normality of t-lgHill estimator in iid setting. In cases of contamination with heavier tails than the tail of original sample, t-Hill outperforms several robust tail estimators, especially in small samples. A simulation study emphasizes the fact that the level of contamination is playing a crucial role. The larger the contamination, the better are the t-score moment estimates. The reason for this is the bounded t-score of heavy-tailed distributions (and, consequently, bounded influence functions of the estimators). We illustrate the developed methodology on a small sample data set of stake measurements from Guanaco glacier in Chile. 相似文献
33.
Jindrich Kynicky Vedran Milosavljevic Pavlina Jelinkova Yazan Haddad Miguel Angel Merlos Rodrigo Hana Buchtelova Zuzana Bytesnikova Martin Brtnicky Lukas Richtera Pavel Kopel Vojtech Adam 《Chemical Papers》2018,72(6):1437-1449
Eu(III) and Tb(III) Schiff base complexes are applicable in various fields such as sensing, assays, screening protocols in vitro, and imaging studies in vitro or in vivo. Fluorescent europium and terbium complexes and their interaction with cell penetrating peptide (KKKRKC) can represent an excellent key for understanding pathway of peptide transportation though cell membrane and the application of Schiff base complexes as potential antibacterial drugs. The Schiff base–metal complexes and its conjugates with peptide were tested for their antibacterial activity against Pseudomonas aeruginosa and Salmonella typhimurium. Schiff base–metal complexes conjugated with peptide show minor toxicity in normal human PNT1A cells and high antibacterial activity against P. aeruginosa and S. typhimurium, where IC50 down to 125.9 and/or 36.1 µM were found for P. aeruginosa and S. typhimurium, respectively. Our results strongly suggest that Schiff base–metal complexes conjugated with peptide have great potential to be developed into highly effective antibacterial drug. 相似文献
34.
35.
Pavlina Kovacheva Katya Arishtirova Albena Predoeva 《Reaction Kinetics and Catalysis Letters》2003,79(1):149-155
The oxidative methylation of toluene with methane is used as a test reaction for determining the activity, selectivity and
yield of C8 hydrocarbons (ethylbenzene and styrene) over different zeolite and zeolite-type catalysts, viz., X, Y, mordenite, ZSM-5, silicalite and AlPO4-5. Selectivity and basicity increase with decreasing Si/Al atomic ratio within the series of the same structural type. The
basicity, surface structure and structural integrity are characterized by TPD of CO2, XPS and IRS, respectively.
This revised version was published online in June 2006 with corrections to the Cover Date. 相似文献
36.
The recent global financial crisis caused implementation of negative or close to zero interest rates. This situation implies a necessity to study a flexible and simplistic model of interest rate, which well accommodates oscillations, cycles, and negative signs. In this article, we introduce a novel nonlinear stochastic interest rate model, which, as a special case, incorporates the standard linear model of Parker. Many practical implications for finance and pensions are obtained. 相似文献
37.
Elisa?Fossale Pavlina?Wolf Janice?A?Espinola Tanya?Lubicz-Nawrocka Allison?M?Teed Hanlin?Gao Dorotea?Rigamonti Elena?Cattaneo Marcy?E?MacDonald Susan?L?CotmanEmail author 《BMC neuroscience》2004,5(1):57
Background
JNCL is a recessively inherited, childhood-onset neurodegenerative disease most-commonly caused by a ~1 kb CLN3 mutation. The resulting loss of battenin activity leads to deposition of mitochondrial ATP synthase, subunit c and a specific loss of CNS neurons. We previously generated Cln3 Δex7/8 knock-in mice, which replicate the common JNCL mutation, express mutant battenin and display JNCL-like pathology. 相似文献38.
39.
Houserová P Matejícek D Kubán V Pavlícková J Komárek J 《Journal of separation science》2006,29(2):248-255
Solvent extraction, sonication, and microwave-assisted extractions in the presence of extraction agents (thioacetic acid, citric acid, cysteine, 2-mercaptoethanol, HCl + NaCl, etc.) were tested for the isolation of mercury species. A mixture of 6 M HCl and 0.1 M NaCl was selected as the most suitable extraction agent. The extraction efficiency was about 10% higher and the RSD below 3.3% when microwave-assisted extraction was applied instead of sonication. The liquid chromatography-cold vapour atomic fluorescence spectrometry (LC/CV-AFS) method was optimised and used for separation and determination of inorganic mercury cations and alkylated and arylated mercury species. Isocratic elution at a flow rate of 0.15 mL/min (with a mobile phase containing 0.05% 2-mercaptoethanol (pH = 5) and 7% methanol and with a stepwise increase of methanol content up to 100% MeOH in the 15th min) was used for separation of mercury species on a Hypersil BDS C18 RP column. The limits of detection of the LC/CV-AFS system were estimated as 0.2 microg/L (3%) for MeHg+, 0.07 microg/L (5.3%) for inorganic Hg, 0.06 microg/L (3.4%) for PhHg+, and 0.12 microg/L (4.4%) for EtHg with the corresponding RSDs at 5 microg/L (n = 10) given in parentheses. The concentrations (2-10 mg/kg fresh weight) of total mercury and methylmercury (90-99% of the total mercury) in selected fish obtained by HPLC/CV-AFS were in good agreement (absolute deviations 0.05 mg/kg) but more precise (RSDs <5.4% at 5 mg/L, n = 10) than those determined by GC coupled to an electron capture detector. The RSDs (3.1-8.2% and 4.1-9.0%) of the overall analytical procedure for the determination of total mercury (AMA 254) and methylmercury (HPLC/CV-AFS) were determined for intra-day and inter-day assays, respectively. 相似文献
40.
A microcoulometric method is described for the determination of organic-halide pollutants at 2-2000 microg/L in natural, drinking, waste, and treated waters. The conditions for the adsorption of organic halides, using a microcolumn with activated charcoal-and for the desorption of inorganic halides-as well as for the pyrolysis process, were optimized for the successful determination of priority organic halide pollutants. An appropriate criterion was proposed to stop the desorption step. The mean recovery was 100.3%, and the mean relative standard deviation was 9.9%. The detection limit based on 3 times the standard deviation of the blank sample was 2 microg/L. 相似文献