首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   200篇
  免费   6篇
  国内免费   3篇
化学   169篇
力学   20篇
数学   7篇
物理学   13篇
  2023年   3篇
  2022年   10篇
  2021年   5篇
  2020年   7篇
  2019年   8篇
  2018年   9篇
  2017年   8篇
  2016年   18篇
  2015年   11篇
  2014年   10篇
  2013年   11篇
  2012年   9篇
  2011年   12篇
  2010年   13篇
  2009年   13篇
  2008年   28篇
  2007年   16篇
  2006年   7篇
  2005年   5篇
  2004年   4篇
  2003年   2篇
排序方式: 共有209条查询结果,搜索用时 15 毫秒
121.
122.
123.
124.
125.
126.
127.
Rapid and practical green acetylation and tetrahydropyranylation routes of structurally diverse alcohols and phenols were applied under solvent-free reaction conditions providing excellent yields, using catalytic amounts of environmentally friendly sulfonated ordered nanoporous carbon (CMK-5-SO3H). Non-toxic nature of the catalyst, its easy handling, recovery and reusability, and the absence of any solvent characterize the presented procedures as efficient methods. These procedures provide methods for the separation of the product by simple filtration.  相似文献   
128.
This paper investigates the inertial and creeping flow of a second-order fluid in a curved duct with a square cross-section. Numerical modeling is employed to analyze fluid flow, and the governing equations are discretized using the finite difference method on a staggered mesh. The marker-and-cell method is employed to allocate the parameters on the staggered mesh, and static pressure is calculated using the artificial compressibility approach. The effect of centrifugal force due to the curvature of the duct and the opposing effects of the first and second normal stress difference on the flow field are investigated. In addition, the order-of-magnitude technique is used to derive the force balance relations for the core region of flow. Based on these relations, the performance mechanism of centrifugal force and normal stress differences on the generation of secondary flows is considered. We also present an analytical relation for the axial velocity profile and flow resistance ratio of creeping flow. For this kind of flow, previous studies have investigated the effect of the first normal stress difference on the transition from one pair to two pairs of vortices while we show that the negative second normal stress difference has the opposite effect on this transition and can stabilize the flow.  相似文献   
129.
A simple and fast stripping voltammetric detection method has been designed for selective and non-selective measurements of heavy metal ions in a flow-injection system. A special computer numerical method is introduced for calculating the analyte signal and noise reduction, where the signal is calculated based on the partial and total charge exchange at electrode surface. For a selective determination, the currents are integrated in the range of the oxidation and reduction of the analyte. For non-selective measurements, the integration range is set for the whole potential scan range (including oxidation and reduction of the Au surface). The time for stripping has been shown to be less than 300 ms. The main advantages of the detection method are as follows: first, removal of oxygen from the measured solution is not required; second, it is sufficiently fast for the determination of heavy metal ions in various chromatographic analysis methods. The limit of detection for tested ions was between 3 x 10(-9) and 6 x 10(-10) M, and the relative standard deviation at 50 ppb Pb2+ was 4.7% for 10 runs.  相似文献   
130.
A method was developed to identify human T-lymphotropic virus-1 (HTLV-1) using cadmium–tellurium quantum dots. Two probes including the biotin-labeled acceptor and NH2-reporter probes with target DNA were hybridized. The resulted sandwich complex was immobilized on a well containing streptavidin. The quantum dot solution was added to the sandwich complex, conjugated with the amine group of reporter probe, and emission spectra of the quantum dots were recorded. The biosensor response was linear with HTLV-1 concentrations from 10 pg/µl to 0.24?ng/µl, with a detection limit of 19.5 pg/µl. The assay may be successfully used for detection of long nucleic acids.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号