排序方式: 共有53条查询结果,搜索用时 0 毫秒
51.
Statistical copolymers of 2-vinylpyridine (VP) with oligo(ethylene glycol) methyl ether methacrylates of two different molecular weights (300 g/mol (OEGMA300) and 1100 g/mol (OEGMA1100)), were prepared by free radical polymerization. The reactivity ratios of these two sets of monomers were estimated using the Finemann–Ross, the inverted Finemann–Ross and the Kelen–Tüdos graphical methods. Structural parameters of the copolymers were obtained by calculating the dyad monomer sequence fractions and the mean sequence length. The effect of the length of the oligo(ethylene glycol) group on the copolymer structure is discussed. The glass-transition temperature (Tg) values of the VP copolymers with OEGMA300 were measured and examined in the frame of several theoretical equations, allowing the prediction of these Tg values. The copolymers of VP with OEGMA1100 exhibited the characteristic melting endotherm, due to the crystallinity of the methacrylate sequences and glass transition temperatures attributed to the PVP sequences. 相似文献
52.
Nikolaos Mitrou Georgia‐Paraskevi Nikoleli Dimitrios P. Nikolelis Nikolas Psaroudakis Michael Scoullos 《Electroanalysis》2014,26(5):919-923
This article describes the development of a calcium solid minisensor based on lipid films on ZnO nanorods. The lipid film was composed from dipalmitoylphosphatidylcholine (DPPC) and dipalmitoylphosphatidylcic acid (DPPA). The calibration graph was logarithmically related to the concentration of calcium ions in the range from 10?6 to 10?3 M. The response times of the electrode were less than 5 s. No memory effects were observed for this electrode. The reproducibility of the electrode was less than 5 %. The electrode has shown good stability for a period of 1 month. The influence of a wide range of metals and anions as potential interferences was checked. The method was applied to the rapid detection of calcium ions in mineral waters. 相似文献
53.
Nikolaos Tzamtzis Vasillios N. Psychoyios Georgia‐Paraskevi Nikoleli Dimitrios P. Nikolelis Nikolas Psaroudakis Magnus Willander Muhammad Qadir Israr 《Electroanalysis》2012,24(8):1719-1725
A novel potentiometric uric acid biosensor was fabricated by immobilization of uricase into stabilized lipid films using zinc oxide (ZnO) nanowires as measuring electrode. Uricase was incorporated into the lipid film prior polymerization on the surface of well aligned ZnO nanowires resulting in a sensitive, selective, stable and reproducible uric acid biosensor. The potentiometric response was twice as large from previously reported values due to the presence of a cationic lipid in the lipid film. The sensor response had no interferences by normal concentrations of ascorbic acid, glucose, urea, proteins and lipids. 相似文献