首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   85篇
  免费   5篇
化学   61篇
数学   3篇
物理学   26篇
  2023年   4篇
  2022年   3篇
  2021年   2篇
  2020年   1篇
  2019年   2篇
  2018年   8篇
  2017年   4篇
  2016年   7篇
  2015年   6篇
  2014年   7篇
  2013年   6篇
  2012年   5篇
  2011年   10篇
  2010年   3篇
  2009年   3篇
  2008年   8篇
  2007年   4篇
  2006年   2篇
  2005年   2篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
排序方式: 共有90条查询结果,搜索用时 31 毫秒
31.
Catalytic adsorptive stripping voltammetry (CAdSV) has been demonstrated at a bismuth film electrode (BiFE) in an injection-moulded electrochemical micro-flow cell. The polystyrene three-electrode flow cell was fabricated with electrodes moulded from a conducting grade of polystyrene containing 40% carbon fibre, one of which was precoated with Ag to enable its use as an on-chip Ag/AgCl reference electrode. CAdSV of Co(II) and Ni(II) in the presence of dimethylglyoxime (DMG) with nitrite employed as the catalyst was performed in order to assess the performance of the flow cell with an in-line plated BiFE. The injection-moulded electrodes were found to be suitable substrates for the formation of BiFEs. Key parameters such as the plating solution matrix, plating flow rate, analysis flow rate, solution composition and square-wave parameters have been characterised and optimal conditions selected for successful and rapid analysis of Co(II) and Ni(II) at the ppb level. The analytical response was linear over the range 1 to 20 ppb and deoxygenation of the sample solution was not required. The successful coupling of a microfluidic flow cell with a BiFE, thereby forming a “mercury-free” AdSV flow analysis sensor, shows promise for industrial and in-the-field applications where inexpensive, compact, and robust instrumentation capable of low-volume analysis is required.  相似文献   
32.
Point-of-care diagnostics requires a smart separation of particles and/or cells. In this work, the multiorifice fluid fractionation as a passive method and dielectrophoresis-based actuator as an active tool are combined to offer a new device for size-based particle separation. The main objective of the combination of these two well-established techniques is to improve the performance of the multiorifice fluid fractionation by taking advantage of dielectrophoresis-based actuator for separating particles. Initially, by using numerical simulations, the effect of using dielectrophoresis-based actuator in multiorifice fluid fractionation on the separation of particles was investigated, and the size of the device was optimized by 25% compared to a device without dielectrophoresis-based actuator. Also, adding dielectrophoresis-based actuator to multiorifice fluid fractionation can extend the range of flow rates needed for separation. In the absence of dielectrophoresis-based actuator, the separation took place only when the flow rate is 100 μL/min, in the presence of dielectrophoresis-based actuator (20 Vp-p), the separation happened in flow rates ranging from 70 to 120 μL/min.  相似文献   
33.
A novel ionic liquid, 1-(ferrocenyl butyl)-3-methylimidazolium tetrafluoroborate (Fc-IL), was synthesised. The nanocomposite of Fc-IL and multi-walled carbon nanotubes (MWCNTs) was constructed and used for surface modification of carbon-ceramic electrode. The modified electrode was applied to the determination of hydrazine. Operational parameters such as pH of the solution, ionic liquid volume and amount of carbon nanotubes, which affect the analytical performance of the modified electrode, were optimised. The linear range of the modified electrode toward hydrazine concentration was 0.96–106.10 μg L–1 with a detection limit of 0.64 μg L–1 (S/N = 3). The modified electrode displayed high repeatability, reproducibility, long-term life time and low response time (<3 s). The applicability of this method was further tested by analysing the hydrazine content in boiler-feed water samples containing different concentrations of hydrazine and the results were in good agreement with the spectrophotometry method.  相似文献   
34.
An air-assisted liquid–liquid microextraction method coupled with a multivariate calibration method, namely partial least squares (PLS), was developed for the extraction and simultaneous determination of benzoic acid (BA) and sorbic acid (SA) via a spectrophotometric approach. In this work, a two-step microextraction method was used. In the first step, analytes were extracted from acidic aqueous solution into octanol, as an organic solvent, and in the second step, the analytes were simultaneously back-extracted into an alkaline aqueous solution. The high absorption signal of octanol was the main reason to perform this back-extraction step. The effects of different parameters on the method efficiency were investigated; the parameters included extraction solvent volume, ionic strength of aqueous solution, pH, number of extraction cycles, and aqueous sample volume. Under optimum conditions, calibration graphs were seen to be linear over the range of 0.1–2.0 µg mL?1 for the both analytes. Other analytical parameters were obtained as follows: Enrichment factors (EFs) were found to be 14.98 and 13.03, and limits of detection were determined to be 0.03 and 0.04 µg mL?1 for BA and SA, respectively. As the last step, binary mixtures of the analytes were prepared and simultaneously extracted using the proposed method. Finally, PLS modeling was used for multivariate calibration of spectrophotometric data. It was successfully utilized for the analysis of the target analytes in real samples.  相似文献   
35.
In this work, a sensitive electrochemical aptasensor for the detection of adenosine triphosphate (ATP) has been introduced. A simple and non-enzymatic signal amplification strategy is utilized using silver nanoparticle-decorated graphene oxide (AgNPs–GO) as a redox probe. The modified electrode surface was characterized by scanning electron microscopy, FTIR and UV–Vis spectroscopy, and electrochemical impedance spectroscopy. GO provides an excellent substrate for the presence of the large number of AgNPs, so the monitored oxidation signal of AgNPs has been amplified. ATP-specific DNA aptamer is split into two fragments (F1 & F2) in order to design a sandwich-type assay. For the construction of the sensor, the surface of a graphite screen-printed electrode is modified with electrodeposited gold nanoparticles followed by self-assembling a monolayer of 3-mercaptopropionic acid on the electrode surface. The first amino-labeled fragment, F1, is immobilized on the modified electrode via carbodiimide chemistry. The synthesized AgNPs–GO interacts with F1 via \(\pi{-}\pi\) stacking. In the presence of ATP, the second fragment of the aptamer, F2, forms an associated complex with the immobilized F1 and causes AgNPs–GO to leave the surface. Consequently, a remarkable decrease in the oxidation signal of the AgNPs is observed. The percentage of this decrease has been monitored as an analytical signal, which is proportional to ATP concentration, and delivers a linear response over the range of 10.0 (±0.6) to 850 (±5) nM with a detection limit of 5.0 (±0.2) nM.  相似文献   
36.
The essential oils of leaves and flowers of Tanacetum dumosum Boiss., an endemic medicinal shrub, were extracted by using hydrodistillation method and analysed using GC and GC–MS. A total of 43 and 44 compounds were identified in the essential oils from the leaves and flowers of T. dumosum, respectively. The major chemical constituents of leaves oil were borneol (27.9%), bornyl acetate (18.4%), 1,8-cineol (17.5%), α-terpineol (5.3%), cis-chrysanthenyl acetate (3.3%), camphene (2.7%) and terpinene-4-ol (1.9%), while the main components of the flower oil were isobornyl-2-methyl butanoate (41.1%), trans-linalyl oxide acetate (11.9%), 1,8-cineole (7.7%), thymol (4.2%), linalool (3.9%), camphor (2.9%), isobornyl propanoate (2.9%), α-terpineol (2.1%) and caryophyllene oxide (2.0%). Major qualitative and quantitative variations for some main chemical compounds among different aerial parts of T. dumosum were identified. High contents of borneol, bornyl acetate, 1,8-cineol and linalool in the leaves and flowers of T. dumosum show its potential for use in the food and perfumery industry.  相似文献   
37.
The preparation and characterization of the compounds trans-M(2)(T(i)PB)(2)(O(2)C-CH=CH-2-C(4)H(3)S)(2) where M = Mo or W and T(i)PB = 2,4,6-triisopropylbenzoate are reported. The optical spectra of the new compounds are compared with those of related trans-M(2)(T(i)PB)(2)L(2) compounds where L = O(2)C-C(6)H(4)-4-CN, O(2)C-α,α'-terthienyl (TTh), and O(2)C-4-C(6)H(4)N-B(C(6)F(5))(3), that show strong metal-to-ligand charge transfer bands because of M(2)δ to Lπ conjugation, and are notably temperature dependant due to the various conformations of the two trans-L groups. Upon cooling the spectral features sharpen as the planar geometry that optimizes M(2)δ-Lπ conjugation is favored. As the electronic coupling of the two trans-Lπ systems increases the (0,0) electronic transition gains intensity indicating a greater nesting of the ground state (S(0)) and excited state (S(1)) potential energy surfaces. These features are discussed in terms of the related electronic coupling of [M(2)]-[M(2)] complexes.  相似文献   
38.
Quantum communication provides an enormous advantage over its classical counterpart: security of communications based on the very principles of quantum mechanics. Researchers have proposed several approaches for user identity authentication via entanglement. Unfortunately, these protocols fail because an attacker can capture some of the particles in a transmitted sequence and send what is left to the receiver through a quantum channel. Subsequently, the attacker can restore some of the confidential messages, giving rise to the possibility of information leakage. Here we present a new robust General Nuser authentication protocol based on N-particle Greenberger–Horne–Zeilinger (GHZ) states, which makes eavesdropping detection more effective and secure, as compared to some current authentication protocols. The security analysis of our protocol for various kinds of attacks verifies that it is unconditionally secure, and that an attacker will not obtain any information about the transmitted key. Moreover, as the number of transferred key bits N becomes larger, while the number of users for transmitting the information is increased, the probability of effectively obtaining the transmitted authentication keys is reduced to zero.  相似文献   
39.
40.
The crucial issue of quantum communication protocol is its security. In this paper, the security of the Quantum Authentication Scheme Based on Entanglement Swapping proposed by Penghao et al. (Int J Theor Phys., doi:10.1007/s10773-015-2662-7) is reanalyzed. It is shown that the original does not complete the task of quantum authentication and communication securely. Furthermore a simple improvement on the protocol is proposed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号