排序方式: 共有134条查询结果,搜索用时 0 毫秒
11.
In this paper,an axial dispersion mathematical model is developed to simulate a three-phase slurry bubble column reactor for direct synthesis of dimethyl ether(DME) from syngas.This large-scale reactor is modeled using mass and energy balances,catalyst sedimentation andsingle-bubble as well as two-bubbles class flow hydrodynamics.A comparison between the two hydrodynamic models through pilot plantexperimental data from the literature shows that heterogeneous two-bubbles flow model is in better agreement with the experimental data thanhomogeneous single-bubble gas flow model.Also,by investigating the heterogeneous gas flow and axial dispersion model for small bubblesas well as the large bubbles and slurry(i.e.including paraffins and the catalyst) phase,the temperature profile along the reactor is obtained.Acomparison between isothermal and non-isothermal reactors reveals no obvious performance difference between them.The optimum values ofreactor diameter and height were obtained at 7 m and 50 m,respectively.The effects of operating variables on the axial catalyst distribution,DME productivity and CO conversion are also investigated in this research. 相似文献
12.
Farzaneh Ahmadi Jahan Bakhsh Raoof Reza Ojani Mehdi Baghayeri Moslem Mansour Lakouraj Hamed Tashakkorian 《催化学报》2015,(3)
Ag nanoparticles were synthesized on the surface of a glassy carbon electrode modified with p‐tert‐butylcalix[4]arene and p‐tert‐butylcalix[6]arene by the deposition of Ag+at an open circuit potential ... 相似文献
13.
A microextraction procedure based on a task‐specific ionic liquid for the separation and preconcentration of lead ions from red lipstick and pine leaves 下载免费PDF全文
Asma Saljooqi Tayebeh Shamspur Maryam Mohamadi Daryoush Afzali Ali Mostafavi 《Journal of separation science》2015,38(10):1777-1783
First, the extraction and preconcentration of ultratrace amounts of lead(II) ions was performed using microliter volumes of a task‐specific ionic liquid. The remarkable properties of ionic liquids were added to the advantages of microextraction procedure. The ionic liquid used was trioctylmethylammonium thiosalicylate, which formed a lead thiolate complex due to the chelating effect of the ortho‐positioned carboxylate relative to thiol functionality. So, trioctylmethylammonium thiosalicylate played the roles of both chelating agent and extraction solvent simultaneously. Hence, there is no need to use a ligand. The main parameters affecting the efficiency of the method were investigated and optimized. Under optimized conditions, this approach showed a linear range of 2.0–24.0 ng/mL with a detection limit of 0.0010 ng/mL. The proposed method was applied to the extraction and preconcentration of lead from red lipstick and pine leaves samples prior to electrothermal atomic absorption spectroscopic determination. 相似文献
14.
Elnaz Iranmanesh Moslem Jahani Azizollah Nezhadali Maliheh Mojarrab 《Journal of separation science》2020,43(6):1164-1172
This paper describes the synthesis of a molecularly imprinted polymer by chemical oxidation of pyrrole as the functional monomer, and at the presence of guaifenesin as the template. The prepared polymer was used as adsorbent in molecularly imprinted solid‐phase extraction followed by spectrophotometric determination. Different parameters in the solid‐phase extraction including sample pH, adsorbent weight, washing solution, and elution solvent were studied to determine optimum conditions for isolation and enrichment of guaifenesin. The results showed guaifenesin was quantitatively adsorbed on the molecularly imprinted polymer at pH 6.0 and completely eluted with an ethanol–water solution (50% v/v). An enrichment factor of four with satisfactory recoveries (87.0–95.0%) was obtained. The solid‐phase extraction columns could be used for up to six consecutive elution‐loading cycles without significant decreases in the analyte recoveries. The method had a dynamic range of 3.0 × 10?6–1.5 × 10?4 mol/L with a limit of detection and limit of quantification of 1.4×10?6 and 4.5×10?6 mol/L, respectively. The proposed procedure was used for the extraction and determination of guaifenesin in different pharmaceutical formulations, with satisfying results being achieved. 相似文献
15.
Naser Seyed-Matin Amir Hossein Jalili Masih Hosseini Jenab Seyed Majid Zekordi Ali Afzali Chapar Rasouli Akbar Zamaniyan 《Plasma Chemistry and Plasma Processing》2010,30(3):333-347
The carbon dioxide reforming of methane to synthesis gas under DC-pulsed plasma was investigated. The effects of specific
input energy and feed ratio on the product distribution and also feed conversion was studied. At the input energy of about
11 eV/molecule per methane and/or carbon dioxide the feed conversion of 38% for CH4 and 28% for CO2 and product selectivity of 74% has been attained for H2 and CO at feed flow rate of 90 ml/min. The energy consumption in this work displays potential to further study and optimization
of the process. The importance of the electron impact reactions in the process was discussed. The results show that by prudent
tuning of system variables, the process be able to run in the way of synthesis gas, instead of hydrocarbon production. 相似文献
16.
In the present work, dispersive liquid-liquid microextraction based on solidification of floating organic drop was developed as a simple and rapid technique for separation of silver ions from aqueous samples. In this technique, 700 μL 0.02% of 5-(4'-dimethylamino benzyliden)-rhodanine (chelating agent) was added into the 10 mL analyte sample in a test tube and 30.0 μL 1-undecanol (extraction solvent) was injected shortly thereafter. The test tubes were sonicated, centrifuged and then some effective parameters on extraction and complex formation, such as type and volume of extraction and disperser solvent, pH, the amount of chelating agent and extraction time were optimized. The effect of the interfering ions on the analytes recovery was also investigated. The calibration graph was linear in the range of 0.10-10.0 ng mL(-1) with detection limit of 0.056 ng mL(-1) (n=8). The relative standard deviation (RSD) was ±4.3% (n=8, C=5.0 ng mL(-1)) and the enrichment factor was 250.0. The proposed method was applied for extraction and determination of silver in different water samples. 相似文献
17.
Rasool Jamshidi Zahra Afzali 《International journal of environmental analytical chemistry》2013,93(9):821-827
A procedure has been proposed for the separation and preconcentration of trace amounts of thallium. It is based on the adsorption of thallium ions onto organo nanoclay loaded with 1-(2-pyridylazo)-2-naphthol (PAN). Thallium ions were quantitatively retained on the column in the pH range of 3.5–6.0, whereas quantitative desorption occurs with 5.0?mL of 5% ascorbic acid and thallium was determined by flame atomic absorption spectrometry. Linearity was maintained between 0.66?ng?mL?1–15.0?µg?mL?1?in initial solution. Detection limit was 0.2?ng?mL?1?in initial solution and preconcentration factor was 150. Eight replicate determinations of 2.0?µg?mL?1 of thallium in final solution gave a relative standard deviation of ±1.48%. Various parameters have been studied, such as the effect of pH, breakthrough volume and interference of a large number of anions and cations and the proposed method was used to determine thallium ions in water and standard samples. Determination of thallium ions in standard sample showed that the proposed method has good accuracy. 相似文献
18.
Biodegradable polyurethane elastomers with potential for applications in medical implants with tunable degradation rate and physical properties were synthesized from reaction of epoxy terminated polyurethanes (EUP) with 1,6-hexamethylene diamine (HMDA) as curing agent. Poly(ε-caprolactone) (PCL) and poly(ethylene glycol) (PEG) as well as 1,6-hexamethylene diisocyanate (HDI) were used for preparation of isocyanate terminated polyurethanes which were subsequently blocked with glycidol to prepare EUPs. All materials were characterized by conventional methods, and their properties were studied fully. Results showed that elastomers based on PEG exhibit superior degradation rate and inferior mechanical properties in comparison to elastomers based on PCL. Optimum degradation rate and mechanical properties were obtained from elastomers made from mixture of PCL and PEG base EUPs. 相似文献
19.
Nonlinear Dynamics - Different architectures and techniques have developed in the neuromorphic field to mimic and investigate the activity of biological neural networks. This paper presents a set... 相似文献
20.
Tulevski GS Miao Q Afzali A Graham TO Kagan CR Nuckolls C 《Journal of the American Chemical Society》2006,128(6):1788-1789
This study describes the effect of covalent derivatization of source and drain electrodes with monolayers of organic semiconductors. These monolayers form a template on the metal surface and provide better electronic coupling between the electrode and the semiconductor. We see a large improvement in nanoscale (40-100 nm) transistors only when the monolayer presents functionality that is complementary to the chemical and electronic structure of the molecular semiconductor. 相似文献