全文获取类型
收费全文 | 694篇 |
免费 | 28篇 |
国内免费 | 15篇 |
专业分类
化学 | 470篇 |
晶体学 | 2篇 |
力学 | 44篇 |
数学 | 108篇 |
物理学 | 113篇 |
出版年
2023年 | 2篇 |
2022年 | 8篇 |
2021年 | 15篇 |
2020年 | 28篇 |
2019年 | 27篇 |
2018年 | 35篇 |
2017年 | 33篇 |
2016年 | 60篇 |
2015年 | 39篇 |
2014年 | 43篇 |
2013年 | 101篇 |
2012年 | 58篇 |
2011年 | 80篇 |
2010年 | 32篇 |
2009年 | 34篇 |
2008年 | 26篇 |
2007年 | 26篇 |
2006年 | 12篇 |
2005年 | 14篇 |
2004年 | 12篇 |
2003年 | 22篇 |
2002年 | 11篇 |
2001年 | 4篇 |
2000年 | 2篇 |
1996年 | 1篇 |
1995年 | 1篇 |
1994年 | 2篇 |
1990年 | 2篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1987年 | 2篇 |
1984年 | 1篇 |
1976年 | 2篇 |
排序方式: 共有737条查询结果,搜索用时 0 毫秒
101.
Central composite design (CCD) and response surface methodology (RSM) were developed as experimental strategies for modeling and optimization of the influence of some variables on the performance of a new PVC membrane triiodide ion-selective electrode. This triiodide sensor is based on triiodide-clozapine ion-pair complexation. PVC, plasticizers, ion-pair amounts and pH were investigated as four variables to build a model to achieve the best Nernstian slope (59.9 mV) as response. The electrode is prepared by incorporating the ion-exchanger in PVC matrix plasticized with 2-nitrophenyl octal ether, which is directly coated on the surface of a graphite electrode. The influence of foreign ions on the electrode performance was also investigated. The optimized membranes demonstrate Nernstian response for triiodide ions over a wide linear range from 5.0 x 10(-6) to 1.0 x 10(-2)mol L(-1) with a limit of detection 2.0 x 10(-6) mol L(-1) at 25 degrees C. The electrodes could be used over a wide pH range 4-8, and have the advantages of easy to prepare, good selectivity and fast response time, long lifetime (over 3 months) and small interferences from hydrogen ion. The proposed electrode was successfully used as indicator electrode in potentiometric titration of triiodide ions and ascorbic acid. 相似文献
102.
Sodium-dicyclohexyl- 18-crown-6 complex cation was used as carrier for the uphill transport of zinc as Zn(SCN)42? complex anion. By using L-cysteine as a metal ion acceptor in the receiving phase at the optimized pH of 7.6, the amount of zinc transport through the liquid membrane after 90 min was 97.2 ± 1.0%. The selectivity and efficiency of zinc transport from aqueous solutions containing equimolar mixtures of Ag+, Cd2+ Co2+, Cu2+, Fe2+, Ni2+, Pb2+, Pd2+, Sr2+, Bi3+, Cr3+ and Fe3+ ions was investigated. In the presence of NH2OH.HCl as a suitable masking agent in the source phase, the interfering effect of Cu2+ and Pb2+ ions was diminished drastically. 相似文献
103.
Individuals may have biased perceptions of health and safety risks. We conjecture perceptions of mortality risk from various risk measures using parametric and non-parametric methods. We investigate how risk perceptions are measured and what rational explanations can be found for these measures with implication for risk and solvency. 相似文献
104.
The mean centering of ratio kinetic profiles method was used for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) in water samples, without prior separation steps. The method is based on the difference in the rate of the reaction of Ni(II) and Zn(II) with xylenol orange at pH 5.3. The method allows rapid and accurate determination of Ni(II) and Zn(II). The analytical characteristics of the methods for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) were calculated. The linear range was 0.025‐2.400 μg mL?1 and 0.025‐2.20 μg mL?1 for Zn(II) and Ni(II), respectively. Interference effects of common anions and cations were studied, and the method was successfully applied to the simultaneous determination of Zn(II) and Ni(II) in water samples. 相似文献
105.
106.
107.
108.
109.
Other Index
Key Word Index of Volume 36 – 2001 相似文献110.
A simple flow injection spectrophotometric method for the determination of nitrite is described. Nitrite injected into the flow system reacts with thiourea in acidic medium and the generated thiocyanate ion reacts with Fe(III) in the reagent solution to produce a highly colored product. The influences of chemical and physical parameters including reagent concentrations, sample volume injected, flow rates of the carrier and reagent solutions, reaction coil length and reaction temperature, were studied and optimum values of these parameters were established. Under the optimum conditions, the calibration curve for nitrite was linear over the concentration range 0.36 - 90 microg ml(-1) without preconcentration and over the range 3.8 - 500 ng ml(-1) with a simple online preconcentration step using an anion exchange column. The corresponding detection limits were 0.36 micro ml(-1) and 3.8 ng ml(-1), respectively. Up to 25 samples can be analyzed per hour, with an average relative standard deviation of < or = 1.2%. Interferences by various foreign ions were studied and the method was applied to the determination of nitrite in water and spiked water samples. 相似文献