排序方式: 共有147条查询结果,搜索用时 9 毫秒
101.
Wei Shi Behnam Faraji Mark Greenberg Jesper Berggren Yu Xiang Mattias Hammar Michel Lestrade Zhi-Qiang Li Z. M. Simon Li Lukas Chrostowski 《Optical and Quantum Electronics》2011,42(11-13):659-666
A multiple quantum well (MQW) transistor vertical-cavity surface-emitting laser (T-VCSEL) is designed and numerically modeled. The important physical models and parameters are discussed and validated by modeling a conventional VCSEL and comparing the results with the experiment. The quantum capture/escape process is simulated using the quantum-trap model and shows a significant effect on the electrical output of the T-VCSEL. The parameters extracted from the numerical simulation are imported into the analytic modeling to predict the frequency response and simulate the large-signal modulation up to 40 Gbps. 相似文献
102.
This paper reports the selective and sensitive voltammetric determination of l-cysteine in the presence of folic acid using ethynylferrocene modified carbon nanotubes paste electrode in 0.1 M phosphate buffer solution (pH 7.0). Using square wave voltammetry, we could measure l-cysteine and folic acid in one mixture independently from each other by a potential difference of about 410 mV for the first time. Square wave voltammetric peak current of l-cysteine and folic acid increased linearly with their concentrations in the ranges of 0.2–250.0 and 1.0–500.0 μmol?L?1, respectively. The detection limits of 0.07 and 0.6 μmol?L?1 were achieved for l-cysteine and folic acid, respectively. The proposed voltammetric sensor was successfully applied to the determination of l-cysteine and folic acid in real samples. 相似文献
103.
104.
105.
Hedieh Pilali Shirin Faraji Kamazani Shahram Moradi Setareh Moghimi Mohammad Mahdavi Loghman Firoozpour 《合成通讯》2016,46(6):563-567
A novel three-step sequence toward benzo[e]imidazo[1,2-c][1,2,3]triazine derivatives is investigated. This pathway started from commercially available starting materials afforded 5a–h in good to excellent yields. In this method, we took the advantage of diazonium chemistry, which was followed by intramolecular N-N bond formation in the construction of N-rich cycles. 相似文献
106.
Mohammad Faraji Parisa Amini Kadijani 《International journal of environmental analytical chemistry》2016,96(15):1430-1439
A new and sensitive precolumn derivatisation with dabsyl chloride was developed for the analysis of melamine in water samples by high-performance liquid chromatography (HPLC) with visible detection. Derivatisation with dabsyl chloride leads to improving sensitivity and hydrophobicity of melamine. Under optimum conditions of derivatisation and microextraction, the method yielded a linear calibration curve ranging from 10 to 2000 µg L?1 with a determination coefficient (R2) of 0.9952. Limit of detection (LOD) and limit of quantification (LOQ) were 2.0 and 6.0 µg L?1, respectively. The relative standard deviation per cent (RSD%) for intraday and inter-day extraction and determination at 20 and 200 µg L?1 levels of melamine was less than 8.2% (n = 6). Finally, the proposed method was successfully applied for the determination of melamine in different water samples and satisfactory results were obtained (relative recovery ≥91%). 相似文献
107.
Faraji S Vazdar M Reddy VS Eckert-Maksic M Lischka H Köppel H 《The Journal of chemical physics》2011,135(15):154310
There has been a substantial amount of theoretical investigations on the photodynamics of pyrrole, often relying on surface hopping techniques or, if fully quantal, confining the study to the lowest two or three singlet states. In this study we extend ab initio based quantum dynamical investigations to cover simultaneously the lowest five singlet states, two π-σ? and two π-π? excited states. The underlying potential energy surfaces are obtained from large-scale MRCI ab initio computations. These are used to extract linear and quadratic vibronic coupling constants employing the corresponding coupling models. For the N-H stretching mode Q(24) an anharmonic treatment is necessary and also adopted. The results reveal a sub-picosecond internal conversion from the S(4) (π-π?) state, corresponding to the strongly dipole-allowed transition, to the S(1) and S(2) (π-σ?) states and, hence, to the ground state of pyrrole. The significance of the various vibrational modes and coupling terms is assessed. Results are also presented for the dissociation probabilities on the three lowest electronic states. 相似文献
108.
Mohammad Rezaee Yadollah YaminiMohammad Faraji 《Journal of chromatography. A》2010,1217(16):2342-2357
Dispersive liquid–liquid microextraction (DLLME) has become a very popular environmentally benign sample-preparation technique, because it is fast, inexpensive, easy to operate with a high enrichment factor and consumes low volume of organic solvent. DLLME is a modified solvent extraction method in which acceptor-to-donor phase ratio is greatly reduced compared with other methods. In this review, in order to encourage further development of DLLME, its combination with different analytical techniques such as gas chromatography (GC), high-performance liquid chromatography (HPLC), inductively coupled plasma-optical emission spectrometry (ICP-OES) and electrothermal atomic absorption spectrometry (ET AAS) will be discussed. Also, its applications in conjunction with different extraction techniques such as solid-phase extraction (SPE), solidification of floating organic drop (SFO) and supercritical fluid extraction (SFE) are summarized. This review focuses on the extra steps in sample preparation for application of DLLME in different matrixes such as food, biological fluids and solid samples. Further, the recent developments in DLLME are presented. DLLME does have some limitations, which will also be discussed in detail. Finally, an outlook on the future of the technique will be given. 相似文献
109.
Fariborz Omidi Monireh Khadem Fatemeh Dehghani Mirghani Seyedsomeah Seyed Jamaleddin Shahtaheri 《Journal of separation science》2020,43(13):2602-2609
In this research, a new ultrasound‐assisted dispersive micro‐solid‐phase extraction method based on N‐doped mesoporous carbon sorbent followed by high‐performance liquid chromatography equipped with diode array detector for trace measurement of 1‐hydroxypyrene as a metabolite of exposure to polycyclic aromatic hydrocarbons was optimized. Herein, the hard template method was used for the preparation of N‐doped mesoporous carbon sorbent. The prepared sorbent was characterized using the Brunauer–Emmett–Teller method, transmission electron microscopy, and elemental analysis. Parameters affecting the extraction of the target metabolite were investigated using the Box–Behnken design method. Considering optimum parameters, the plotted calibration curve for 1‐hydroxypyrene was linearly correlated with the concentration span of 0.1–50 μg/L for urine media. The accuracy of the optimized procedure was examined through the relative recovery tests on the fortified urine specimens. The relative recoveries fell between 95 and 101%. The method detection limit of the proposed procedure was also calculated to be 0.03 μg/L. 相似文献
110.
Hakim Faraji Mohammad Saber TehraniSyed Waqif Husain 《Journal of chromatography. A》2009,1216(49):8569-8574
Pre-concentration and determination of 8 phenolic compounds in water samples has been achieved by in situ derivatization and using a new liquid–liquid microextraction coupled GC–MS system. Microextraction efficiency factors have been investigated and optimized: 9 μL 1-undecanol microdrop exposed for 15 min floated on surface of a 10 mL water sample at 55 °C, stirred at 1200 rpm, low pH level and saturated salt conditions. Chromatographic problems associated with free phenols have been overcome by simultaneous in situ derivatization utilizing 40 μL of acetic anhydride and 0.5% (w/v) K2CO3. Under the selected conditions, pre-concentration factor of 235–1174, limit of detection of 0.005–0.68 μg/L (S/N = 3) and linearity range of 0.02–300 μg/L have been obtained. A reasonable repeatability (RSD ≤ 10.4%, n = 5) with satisfactory linearity (0.9995 ≥ r2 ≥ 0.9975) of results illustrated a good performance of the present method. The relative recovery of different natural water samples was higher than 84%. 相似文献