排序方式: 共有25条查询结果,搜索用时 15 毫秒
21.
22.
Jamshid L. Manzoori Hossein Abdolmohammad-Zadeh Mohammad Amjadi 《Mikrochimica acta》2007,159(1-2):71-78
A simple and sensitive cloud point extraction method has been developed for the preconcentration of ultra-trace amounts of
gold as a prior step to its determination by electrothermal atomic absorption spectrometry. It is based on the extraction
of gold in hydrochloric acid medium using the non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) without adding a chelating agent. The preconcentration of a 50 mL sample solution was thus enhanced
by a factor of 200. The resulting calibration graph was linear in the range of 10–200 ng L−1 with a correlation coefficient of 0.9993. The limit of detection (3s) obtained under optimal conditions was 2.0 ng L−1. The relative standard deviation for 10 replicate determinations at a 100 ng L−1 Au level was 3.6%. The method was applied to the ultra-trace determination of gold in water and copper samples. 相似文献
23.
Azimi Mitra Manzoori Jamshid L Amjadi Mohammad Abolhasani Jafar 《Journal of Analytical Chemistry》2021,76(10):1217-1224
Journal of Analytical Chemistry - The application of sulfur and nitrogen co-doped carbon quantum dot?potassium permanganate chemiluminescence (CL) system for the determination of trace... 相似文献
24.
Mohammad Amjadi Jamshid L. Manzoori Tooba Hallaj Mohammad H. Sorouraddin 《Mikrochimica acta》2014,181(5-6):671-677
We show that the very weak chemiluminescence (CL) of the Ce(IV)-thiosulfate system is enhanced by a factor of ~150 in the presence of fluorescent carbon dots (C-dots). The C-dots were prepared by a solvothermal method and characterized by fluorescence spectra and transmission electron microscopy. Possible mechanisms that lead to the effect were elucidated by recording fluorescence and CL spectra. It is found that dopamine at even nanomolar levels exerts a diminishing effect on the enhancement of CL. This was exploited to design a method for the determination of dopamine in the concentration range from 2.5 nM to 20 μM, with a limit of detection (at 3 s) of 1.0 nM. Dopamine was determined by this method in spiked human plasma samples with satisfactory results. Figure
Ce(IV)-Na2S2O3 CL reaction is dramatically enhanced by carbon dots. Based on the diminishing effect of dopamine on this new CL system, a sensitive method was developed for its determination. 相似文献
25.
We describe a new chemiluminescence (CL) system based on the oxidation of rhodamine B (RhoB) with alkaline potassium permanganate in the presence of gold nanoparticles (Au-NPs) and anionic detergent sodium dodecyl sulfate. Free RhoB is weakly chemiluminescent when oxidized with permanganate at alkaline pH values. However, a remarkably strong enhancement of CL is observed in the presence of Au-NPs, probably due to a strong interaction between RhoB and the NPs. The possible mechanism was studied via recording the CL emission. It is also found that the intensity of CL gradually decreases in the presence of cyanide due to its interaction with the Au-NPs. The relation between the decreased CL intensity and cyanide concentration was exploited to develop a method for the determination of cyanide in the 0.01–0.5 μM concentration range, with a detection limit of 2.8 nM. The method was used to determine cyanide in spiked water, urine, and serum. Figure
Alkaline permanganate-rhodamine B-SDS CL reaction is dramatically enhanced by gold nanoparticles. Based on the inhibiting effect of cyanide on this system, a sensitive CL method was developed for its determination 相似文献