排序方式: 共有54条查询结果,搜索用时 15 毫秒
51.
Trischuk W de Troconiz JF Truitt S Tseng J Turini N Ukegawa F Valls J Vejcik S Velev G Vidal R Vilar R Vologouev I Vucinic D Wagner RG Wagner RL Wahl J Wallace NB Walsh AM Wang C Wang CH Wang MJ Watanabe T Waters D Watts T Webb R Wenzel H 《Physical review letters》2000,84(5):835-840
We present the results of a search for pair production of a fourth-generation charge -1 / 3 quark (b(')) in sqrt[s] = 1.8 TeV p&pmacr; collisions using 88 pb(-1) of data obtained with the Collider Detector at Fermilab. We assume that both quarks decay via the flavor-changing neutral current process b(')-->bZ(0) and that the b(') mass is greater than m(Z)+m(b). We studied the decay mode b(')b(');-->Z(0)Z(0)b&bmacr; where one Z0 decays into e(+)e(-) or &mgr;(+)&mgr;(-) and the other decays hadronically, giving a signature of two leptons plus jets. An upper limit on the sigma(p&pmacr;-->b(')b(');)x[B(b(')-->bZ(0))](2) is established as a function of the b(') mass. We exclude at 95% confidence level a b(') quark with mass between 100 and 199 GeV/c(2) for B(b(')-->bZ(0)) = 100%. 相似文献
52.
Zwanenburg MJ Bongaerts JH Peters JF Riese DO van Der Veen JF 《Physical review letters》2000,85(24):5154-5157
We have determined the structure of a colloidal fluid confined in a gap between two walls by making use of the waveguiding properties of the gap at x-ray wavelengths. The method is based on an analysis of the coupling of waveguide modes induced by the density variations in the confined fluid. Studies on suspensions confined within gaps of a few hundred nanometers showed strongly selective mode coupling effects, indicative of an ordering of the colloidal particles in layers parallel to the confining walls. 相似文献
53.
Theriot D Thurman-Keup R Tipton P Tkaczyk S Tollefson K Tollestrup A Toyoda H Trischuk W de Troconiz JF Tseng J Turini N Ukegawa F Vaiciulis T Valls J Vejcik S Velev G Vidal R Vilar R Volobouev I Vucinic D Wagner RG Wagner RL Wahl J Wallace NB Walsh AM Wang C 《Physical review letters》2000,85(16):3347-3352
This Letter describes a direct measurement of the W boson total decay width, gamma(W), using the Collider Detector at Fermilab. The measurement uses an integrated luminosity of 90 pb(-1), collected during the 1994-1995 run of the Fermilab Tevatron p&pmacr; collider. The width is determined by normalizing predicted signal and background distributions to 49 844 W-->enu candidates and 21 806 W-->&mgr;nu candidates in the transverse-mass region M(T)<200 GeV and then fitting the predicted shape to the 438 electron events and 196 muon events in the high- M(T) region, 100相似文献
54.
Clauwaert KM Van Bocxlaer JF Major HJ Claereboudt JA Lambert WE Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献