首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   51篇
  免费   8篇
化学   57篇
物理学   2篇
  2020年   2篇
  2019年   1篇
  2016年   3篇
  2015年   3篇
  2014年   6篇
  2013年   4篇
  2012年   2篇
  2011年   6篇
  2010年   2篇
  2009年   1篇
  2008年   4篇
  2007年   1篇
  2006年   2篇
  2005年   4篇
  2004年   2篇
  2003年   4篇
  2002年   2篇
  2001年   4篇
  2000年   5篇
  1999年   1篇
排序方式: 共有59条查询结果,搜索用时 281 毫秒
31.
Hyphenation of micro-liquid and ultra-performance liquid chromatography with a hybrid (QqTOF) tandem mass spectrometry was studied from the viewpoint of their applicability for monitoring of anthocyanin dyes in various cultivars and different vintages of red wine. After appropriate optimization both techniques proved to be suitable for this task. UHPLC system provided lower LOD and LOQ values as well as higher productivity and precision of retention parameters and peak areas with respect to micro-LC method. On the other hand, micro-LC method offers significant savings of mobile phase, less contamination of ion source of mass spectrometer and makes the nebulization process in electrospray much easier. In combination with principal component analysis (PCA), the method allows to elucidate long-term relations in a complete set of certified red wine cultivars grown in South Moravia (certified in Czech Republic until year 2005). Among the studied varieties Rubinet exhibit a specific anthocyanin profile. Especially interesting is a high content of 3-coumaroylglucoside-5-glucosides of malvidin and peonidin. Those dyes can be used as markers of artificial color enhancement. Principal component analysis applied to data processed with regard to enzymatic activity markedly facilitate classification among varieties. This approach allows resolution of teinturiers, variety Blaufränkish and partial classification of other varieties.  相似文献   
32.
The electrochemical behavior of the herbicide metribuzin (4-amino-6-tert-butyl-4,5-dihydro-3-methylthio-1,2,4-triazin-5-one) at mercury electrodes was studied in aqueous solutions by direct current (DC) and tast polarography, differential pulse (DPV) and cyclic voltammetry (CV), and controlled-potential coulometry. The electrolysis products were separated and identified by chromatographic techniques combined with mass spectrometric detection. The reduction process in acid media includes two irreversible steps. In the first four-electron step the N-NH2 and the 1,6-azomethine bonds are reduced. The second step leads to the formation of 5-tert-butyl-2,3,4,5-tetrahydroimidazol-4-one at the mercury-pool electrode. The first reduction step combined with adsorptive accumulation of the herbicide molecule at the mercury electrode surface was used for its determination by differential pulse adsorptive stripping voltammetry (DPAdSV). Calibration curves were linear in the range 1-30 microg L(-1) with a detection limit of 0.27 microg L(-1) (1 nmol L(-1)) under the conditions used (buffer pH 4.5, Eacc = -0.45 V relative to Ag/AgCl and tacc = 10 s). Preconcentration on solid-phase extraction columns (SPE-phenyl) was used for the determination of very small amounts of metribuzin in river water samples. Recovery was approximately 97%. The reproducibility of the analytical procedure including SPE treatment and DPV determination was expressed as relative standard deviations of 2.53 and 3.66% for 2 and 6 microg L(-1) metribuzin, respectively.  相似文献   
33.
The electrochemical behavior of the herbicide metribuzin (4-amino-6-tert-butyl-4,5-dihydro-3-methylthio-1,2,4-triazin-5-one) at mercury electrodes was studied in aqueous solutions by direct current (DC) and tast polarography, differential pulse (DPV) and cyclic voltammetry (CV), and controlled-potential coulometry. The electrolysis products were separated and identified by chromatographic techniques combined with mass spectrometric detection. The reduction process in acid media includes two irreversible steps. In the first four-electron step the N–NH2 and the 1,6-azomethine bonds are reduced. The second step leads to the formation of 5-tert-butyl-2,3,4,5-tetrahydroimidazol-4-one at the mercury-pool electrode. The first reduction step combined with adsorptive accumulation of the herbicide molecule at the mercury electrode surface was used for its determination by differential pulse adsorptive stripping voltammetry (DPAdSV). Calibration curves were linear in the range 1–30 μg L–1 with a detection limit of 0.27 μg L–1 (1 nmol L–1) under the conditions used (buffer pH 4.5, Eacc = –0.45 V relative to Ag/AgCl and tacc = 10 s). Preconcentration on solid-phase extraction columns (SPE-phenyl) was used for the determination of very small amounts of metribuzin in river water samples. Recovery was approximately 97%. The reproducibility of the analytical procedure including SPE treatment and DPV determination was expressed as relative standard deviations of 2.53 and 3.66% for 2 and 6 μg L–1 metribuzin, respectively.  相似文献   
34.
Scanning electron microscopy was used to investigate rivulets that are formed on the analyzed surface during desorption electrospray ionization (DESI) experiment. Ferromagnetic nanoparticles added to the spray solvent in a form of colloid solution functioned as an additional surface probe. The existence of the rivulets was confirmed on glass and newly demonstrated on two different types of porous polytetrafluoroethylene (PTFE). The results show that in standard DESI set-up the rivulets are arranged into very regular shapes. Same rivulets were obtained in DESI experiments without high voltage on the sprayer. However, no such rivulets or any other regular patterns were found on a surface in nano-DESI (nanospray DESI without the carrier nebulizing gas) experiments. This indicates that symmetrical rivulets are created by the hydrodynamical rather than electrostatic forces. It was also demonstrated that blocking the rivulets by a simple physical barrier did not influence known surface charging effects.  相似文献   
35.
Desorption electrospray ionization (DESI) mass spectrometry appears to be a useful technique applicable in different areas (e.g. analysis of pharmaceuticals, identification of biologically active compounds in tissues, imaging mass spectrometry). Its modification termed desorption nano-electrospray (nano-DESI) was tested for analysis of anthocyanins. Acidifying of samples and acidic spray liquid (methanol:water = 75:25 with 0.2% HCOOH) were essential for obtaining good quality spectra. Profiles of main anthocyanins in wine samples, two vintages (2005 and 2007) of three cultivars (Alibernet, Neronet and Rubinet), were successfully acquired. They were in agreement with results of LC/MS experiments (anthocyanins isolated by solid phase extraction were separated by μ-HPLC with gradient elution and detected by ESI-MS). Nano-DESI-MS data also allowed to determine ratio of two cultivars (Neronet and Rubinet) in their mixture and to detect coloring of wine by tenturier or elderberry extract. Detection of main anthocyanins in slices of wine grape, chokeberries and elderberries or in a wine stain on cotton fabric is also presented.  相似文献   
36.
Multimode ionization source allows for switching between different ionization techniques, for example, electrospray and atmospheric pressure chemical ionization, within a single analysis. Supercritical fluid chromatography can handle a wide polarity range of substances from hydrophilic to lipophilic in a single run and can undoubtedly benefit from versatility of this ion source. Nevertheless, we observed a significant chromatographic peak broadening effect in atmospheric pressure chemical ionization mode during supercritical fluid chromatography‐mass spectrometry analysis of volatile flavor compounds with a dual ion source named ESCi (Waters). Surprisingly, this effect was not related to the separation process but was triggered solely by the ion source conditions. Neither of photodiode array detector, electrospray mode nor a dedicated atmospheric pressure chemical ionization source suffered from such a phenomenon. Chromatographic peak profiles of ten test substances obtained with the dual ion source were compared with photodiode array detector data as a reference. The broadening effect was more pronounced for volatile compounds with low polarity. Dependence of peak broadening on the ion source settings was systematically investigated. Tuning of desolvation gas flow and its temperature dramatically reduced peak distortion and increased detection sensitivity.  相似文献   
37.
Although there are existing methods for determining estrogen in human bodily fluids including blood plasma and serum, very little information is available regarding estrogen levels in human cerebrospinal fluid (CSF), which is critical to assess in studies of neuroprotective functions and diffusion of neuroprotective estrogens across the blood–brain barrier. To address this problem, a liquid chromatography with tandem mass spectrometry method for the simultaneous quantification of four endogenous estrogens (estrone, 17α‐estradiol, 17β‐estradiol, and estriol) in human CSF was developed. An aliquot (300 μL) of human CSF was bulk derivatized using dansyl chloride in the sample and 10 μL was directly injected onto a restricted‐access media trap column for protein removal. No off‐line sample extraction or cleanup was needed. The limits of detection of estrone, 17α‐estradiol, 17β‐estradiol, and estriol were 17, 28, 13, and 30 pg/mL, respectively, which is in the parts‐per‐trillion regime. The method was then applied to human CSF collected from ischemic trauma patients. Endogenous estrogens were detected and quantified, demonstrating the effectiveness of this method.  相似文献   
38.
The kinetic method has been applied for determination of d-Phe/l-Phe enantiomeric ratio. Discrimination of enantiomers was inferred from product ion mass spectra of trimeric cluster ions containing the analyte (l,d-Phe), Cu2+ as a central metal and l-Trp as a chiral reference ligand. Unsatisfactory quantitative results achieved on an ion trap were rationalized by high-resolution mass spectrometry. The formation of Mg2+-containing cluster isobaric to trimeric cluster [Cu(l-Trp)2Phe]+ was observed. Interference like this was identified as a possible reason for deterioration of quantitative low-resolution mass spectrometric analyses of real-world samples based on the kinetic method. Cation-exchanger was used for easy removal of magnesium from a sample and improvement of quantitation.Chiral dependence of formation of the Cu2+-containing trimeric cluster was also observed. Heterochiral diastereoisomeric ions were created less effectively.  相似文献   
39.
This work focused on the development and validation of the analytical procedure using gas chromatography equipped with vacuum‐ultraviolet detection for the specific and sensitive determination of nine photoinitiators in food packages. Subsequently, a comparison of the combination of vacuum ultraviolet spectroscopy with gas chromatography and a developed gas chromatography with mass spectrometry method was performed. The vacuum‐ultraviolet spectra of all tested photoinitiators were collected and found to be highly distinct, even for isomers. Under the optimal conditions, the limits of detection for nine photoinitiators ranged from 1 to 5 mg/L using vacuum ultraviolet detection and from 0.15 to 0.5 mg/L using mass spectrometric detection. Both techniques were successfully applied for screening of photoinitiators in seven kinds of food packages and the obtained data showed good agreement (the relative difference was between 3 and 18%). The variability in concentrations found in triplicate samples was assessed to be below 18%. Predominantly benzophenone was found in all analysed samples in the range of 0.31–4.23 mg/kg. It appears to be preferably selected by food packaging manufacturers. This study proposes a new simple and sensitive technique used for analysis of photoinitiators that could be a good alternative to gas chromatography with mass spectrometry.  相似文献   
40.
The amino alcohols in l‐ valinol were effectively separated and quantified using hydrophilic interaction chromatography with fluorescence detection. The influence of the mobile phase (salt type, buffer concentration, and pH) on retention was studied. A column TSKgel amide and mobile phase consisting of 10 mM acetate buffer pH 4.0 and acetonitrile (20:80, v/v) provided well‐ separated symmetric peaks of analytes. Fluorescence detection was performed using postcolumn derivatization with o‐phtaldialdehyde/2‐mercaptoethanol at an excitation and emission wavelength of 345 and 450 nm, respectively. Simple sample pretreatment and very high sensitivity represent the main advantages of the developed method. After validation, the method was successfully applied to the analysis of commercial samples of l‐ valinol.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏