排序方式: 共有32条查询结果,搜索用时 31 毫秒
11.
12.
13.
Marijke WA de Backer Carlos P Fitzsimons Maike AD Brans Mieneke CM Luijendijk Keith M Garner Erno Vreugdenhil Roger AH Adan 《BMC neuroscience》2010,11(1):81
Background
This study compared the transduction efficiencies of an adeno-associated viral (AAV) vector, which was pseudotyped with an AAV1 capsid and encoded the green fluorescent protein (GFP), with a lentiviral (LV) vector, which was pseudotyped with a VSV-G envelop and encoded the discosoma red fluorescent protein (dsRed), to investigate which viral vector transduced the lateral hypothalamus or the amygdala more efficiently. The LV-dsRed and AAV1-GFP vector were mixed and injected into the lateral hypothalamus or into the amygdala of adult rats. The titers that were injected were 1 × 108 or 1 × 109 genomic copies of AAV1-GFP and 1 × 105 transducing units of LV-dsRed. 相似文献14.
Monitoring the real-time behavior of spatial arrays of single living bacteria cells is only achieved with much experimental difficulty due to the small size and mobility of the cells. To address this problem, we have designed and constructed a simple microfluidic device capable of trapping single bacteria cells in spatially well-defined locations without the use of chemical surface treatments. The device exploits hydrodynamics to slow down and trap cells flowing near a narrow aperture. We have modeled this system numerically by approximating the motion of Escherichia coli cells as rigid 3-D ellipsoids. The numerical predictions for the speed and efficiency of trapping were tested by fabricating the devices and imaging GFP expressing E. coli at a high spatio-temporal resolution. We find that our numerical simulations agree well with the actual cell flow for varying trap geometries. The trapped cells are optically accessible, and combined with our ability to predict their spatial location we demonstrate the ease of this method for monitoring multiple single cells over a time course. The simplicity of the design, inexpensive materials and straightforward fabrication make it an accessible tool for any systems biology laboratory. 相似文献
15.
AM Cardoso SM Alexandre CM Barros AJ Correia NM Nibbering 《Rapid communications in mass spectrometry : RCM》1999,13(19):1885-1888
The collision-induced dissociation (CID) of deprotonated arylalkylamines of general formula R(1)C(6)H(4)CHR(2)CH(2)NR(3)(2) (where R(1) = H, OH, F or NO(2); R(2) = H or OH; R(3) = H or CH(3)) generated by negative chemical ionization with H(2)O and D(2)O as ionizing reagents, is discussed. The negative chemical ionization mass spectra show that, in the absence of a hydroxy group in the aromatic ring, deprotonation takes place at the benzylic position whereas the proton is lost from the OH group when present. The nitro compound forms only M(-.) ions. The CID spectra of the deprotonated molecules show that fragmentations are strongly dependent on the structural features of the molecules, namely the presence or absence of substituents in the aromatic ring or aliphatic chain. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
16.
AM Johnston CM Scrimgeour MO Henry LL Handley 《Rapid communications in mass spectrometry : RCM》1999,13(14):1531-1534
The conversion of nitrate (NO(3)(-)) to 1-phenylazo-2-naphthol (Sudan-1) has been examined as a method for natural abundance measurement of delta(15)N of NO(3)(-). The reaction results in dilution of NO(3)(-)-N with only one reagent-derived N and the product is readily concentrated from dilute samples by reverse phase chromatography. There is systematic isotopic fractionation during the reaction, but this can be allowed for by analysing known NO(3)(-) standards along with each sample set. Sudan-1 prepared from surface water samples containing approximately 50 &mgr;g NO(3)(-)-N can be analysed by automated continuous flow isotope ratio mass spectrometry with a precision of 0.2 per thousand (one standard deviation) and the accuracy is not affected by interference from other nitrogenous species in the sample or reagents. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
17.
We report a low cost, disposable polymer microfluidic sample preparation device to perform rapid concentration of bacteria from liquid samples using enhanced evaporation targeted at downstream detection using surface enhanced Raman spectroscopy (SERS). The device is composed of a poly(dimethylsiloxane) (PDMS) liquid sample flow layer, a reusable metal airflow layer, and a porous PTFE (Teflon?) membrane sandwiched in between the liquid and air layers. The concentration capacity of the device was successfully demonstrated with fluorescently tagged Escherichia coli (E. coli). The recovery concentration was above 85% for all initial concentrations lower than 1 × 10(4) CFU mL(-1). In the lowest initial concentration cases, 100 μL initial volumes of bacteria solution at 100 CFU mL(-1) were concentrated into 500 nL droplets with greater than 90% efficiency in 15 min. Subsequent tests with SERS on clinically relevant Methicillin-Sensitive Staphylococcus aureus (MSSA) after concentration in this device proved more than 100-fold enhancement in SERS signal intensity compared to the signal obtained from the unconcentrated sample. The concentration device is straightforward to design and use, and as such could be used in conjunction with a number of detection technologies. 相似文献
18.
S Rayaprol Krushna Mavani CM Thaker DS Rana Keka Chakravorty SK Paranjape M Ramanadham Nilesh A Kulkarni DG Kuberkar 《Pramana》2002,58(5-6):877-880
A new series of mixed oxide superconductors with the stoichiometric composition La2−x
Dy
x
Ca
y
Ba2Cu4+y
O
z
(x=0.0 − 0.5, y=2x) has been studied for structural and superconductiong properties. Our earlier studies on La2−x
(Y/Er)
x
Ca
y
Ba2Cu4+y
O
z
series, show a strong dependence of T
c on hole concentration (p
sh). In the present work, the results of the analysis of the neutron diffraction measurements at room temprerature on x=0.3 and 0.5 samples are reported. It is interesting to know that Ca substitutes for both La and Ba site with concomitant
displacement of La onto Ba site. Superconductivity studies show that maximum T
c is obtained for x=0.5, y=1.0 sample (T
c ∼ 75 K), for La1.5Dy0.5Ca1Ba2Cu5O
z
(La-2125). 相似文献
19.
20.
Finite element error bounds for a curve shrinking with prescribed normal contact to a fixed boundary
We approximate the evolution of a curve subject to motion bycurvature by linear finite elements. The curve evolves insidea given domain and meets orthogonally. We derive optimal boundsfor the error with respect to the L2- and H1-norms and presentsome computed examples. 相似文献