首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   157篇
  免费   5篇
  国内免费   6篇
化学   137篇
力学   9篇
数学   15篇
物理学   7篇
  2021年   4篇
  2020年   6篇
  2019年   8篇
  2018年   7篇
  2017年   4篇
  2016年   9篇
  2015年   6篇
  2014年   8篇
  2013年   17篇
  2012年   16篇
  2011年   15篇
  2010年   9篇
  2009年   18篇
  2008年   11篇
  2007年   11篇
  2006年   5篇
  2005年   3篇
  2004年   4篇
  2002年   3篇
  2000年   1篇
  1999年   1篇
  1997年   1篇
  1995年   1篇
排序方式: 共有168条查询结果,搜索用时 0 毫秒
1.
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations.  相似文献   
2.
A ZnAl2O4@SiO2 nanocomposite was prepared from metal nitrates and tetraethyl orthosilicate by the sol-gel process, and characterized by X-ray diffraction, Fourier transform infrared, transmission electron microscopy, and N2 adsorption-desorption measurements. The nanocomposite was tested as a heterogeneous catalyst for the acetylation of alcohols, phenols, and amines under solvent-free conditions. Under optimized conditions, efficient acetylation of these substrates with acetic anhydride over the ZnAl2O4@SiO2 nanocomposite was obtained. Acetylation of anilines and primary aliphatic amines proceeded rapidly at room temperature, while the reaction time was longer for the acetylation of alcohols and phenols, showing that an amine NH2 group can be selectively acetylated in the presence of alcoholic or phenolic OH groups. The catalyst can be reused without obvious loss of catalytic activity. The catalytic activity of the ZnAl2O4@SiO2 nanocomposite was higher than that of pure ZnAl2O4. The method gives high yields, and is clean, cost effective, compatible with substrates having other functional groups and it is suitable for practical organic synthesis.  相似文献   
3.
This is a survey of some recent results on spherical tropical geometry.  相似文献   
4.
5.
A multicomponent electrochemical sensor, with two nanometer-scale components in sensing matrix/electrode, was used to simultaneous determination of levodopa (LD) and tyramine (TR) in pharmaceutical and diet samples. Multiwall carbon nanotubes (MWCNTs) were used as carbonaceous materials in the electrode construction. 5-amino-3',4'-dimethoxy-biphenyl-2-ol (5ADMB) was used as electron mediator and Pt nanoparticles (nPt) as a catalyst. The 5ADMB catalyzes the oxidation of LD to the corresponding catecholamine, which is electrochemically reduced back to LD. Preparation of this electrode was very simple and modified electrode showed good properties at electrocatalytic oxidization of LD and TR. Using differential pulse voltammetry (DPV), a highly selective and simultaneous determination of LD and TR has been explored at the modified electrode. Differential pulse voltammetry peak currents of LD and TR increased linearly with their concentrations at the ranges of 0.50–100.0 μM and 0.60–100.0 μM, respectively. Also, the detection limits for LD and TR were 0.31 and 0.52 μM, respectively. The electrode exhibited an efficient catalytic response with good reproducibility and stability.  相似文献   
6.

Permselective modifier films are very important in preparing highly sensitive electrochemical sensors. In this work, for the first time, the behavior of gold and glassy carbon electrodes coated with biocompatible zein film as a permselective membrane for the electrochemical detection of various compounds has been investigated. For this purpose, several electroactive cationic (methylene blue, brilliant green, and thionine) and anionic (potassium ferricyanide, alizarin red S, and riboflavin-5’-phosphate) compounds have been used as model. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) showed that zein membranes prepared from casting solution containing 1% zein in ethanol/water have porous structures with high nanometric roughness. The capacitance values of electrical double layers of electrodes modified with zein film were very high for hydrophilic ions in comparison with hydrophobic ions. Point of zero charge pH (pHpzc) of zein membrane was 4.8. The results of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) as well as pHpzc study indicated that zein permselective membrane acts as ion exchanger film for selected cationic compounds with fast electrochemical kinetics responses in aqueous solution (pH=7). This behavior was confirmed by circulating solutions containing model compounds from homemade continuous cell equipped with polyamide membranes modified with zein film.

Graphical Abstract
  相似文献   
7.
A simple, efficient and practical procedure for the Biginelli reaction using zinc oxid (ZnO) as a novel and reusable catalyst is described under solvent-free conditions in high yields. The use of this agent is characterized by remarkable reactivity, moderate costs, low toxicity and simple work up procedures.  相似文献   
8.
Dispersive liquid–liquid microextraction (DLLME) in conjunction with high-performance liquid chromatography-diode array detection (HPLC-DAD) has been applied to the extraction and determination of EDTA in sediments and water samples. The effect of extraction, nature and volume of disperser solvent, pH value of sample solution, extraction time and extraction temperature were investigated. Under the optimal conditions the analytical range of EDTA was from 3.0 to 50.0 μg L?1 with a correlation coefficient of 0.9982 and a detection limit of 1.7 μg L?1. The relative standard deviation (RSD) was less than 5.4% (n?=?5), and the recovery values were in the range of 89–95%. The simplicity, high enrichment, high recovery and good repeatability are the main advantages of the method presented. The DLLME-HPLC-DAD method was successfully applied to the analysis of EDTA in aqueous samples.  相似文献   
9.
A wide variety of oximes and alcohols were efficiently converted to their corresponding aldehydes and ketones in good to excellent yields using amberlite IRA-400 supported chromic acid in the presence of zirconium tetrachloride in refluxing acetonitrile-H2O. Selective oxidation of oximes and alcohols in the presence of other functional groups such as acetal, hydrazone, aldehyde, ether and alkene can be considered as a noteworthy advantage of this method. A wide variety of oximes and alcohols were efficiently converted to their corresponding aldehydes and ketones in good to excellent yields using amberlite IRA-400 supported chromic acid in the presence of zirconium tetrachloride in refluxing acetonitrile-H2O. Selective oxidation of oximes and alcohols in the presence of other functional groups such as acetal, hydrazone, aldehyde, ether and alkene can be considered as a noteworthy advantage of this method.  相似文献   
10.
A partial least squares (PLS-1) calibration model based on kinetic—spectrophotometric measurement, for the simultaneous determination of Cu(II), Ni(II) and Co(II) ions is described. The method was based on the difference in the rate of the reaction between Co(II), Ni(II) and Cu(II) ions with 1-(2-pyridylazo)2-naphthol in a pH 5.8 buffer solution and in micellar media at 25°C. The absorption kinetic profiles of the solutions were monitored by measuring the absorbance at 570 nm at 2 s intervals during the time range of 0–10 min after initiation of the reaction. The experimental calibration matrix for the partial least squares (PLS-1) model was designed with 30 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.1-2 μg mL−1 for each cation. The proposed method was successfully applied to the simultaneous determination of Cu(II), Ni(II) and Co(II) ions in water and in synthetic alloy samples.   相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号