首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   339篇
  免费   18篇
化学   290篇
晶体学   1篇
力学   3篇
数学   38篇
物理学   25篇
  2023年   7篇
  2022年   36篇
  2021年   44篇
  2020年   12篇
  2019年   7篇
  2018年   9篇
  2017年   15篇
  2016年   33篇
  2015年   15篇
  2014年   10篇
  2013年   28篇
  2012年   27篇
  2011年   16篇
  2010年   14篇
  2009年   14篇
  2008年   21篇
  2007年   9篇
  2006年   12篇
  2005年   9篇
  2004年   6篇
  2003年   6篇
  2002年   2篇
  2001年   2篇
  2000年   1篇
  1992年   1篇
  1990年   1篇
排序方式: 共有357条查询结果,搜索用时 62 毫秒
301.
302.
A new type of carbon ceramic electrode modified with bismuth oxide nanoparticles (referred to as Bi-CCE) was fabricated via the sol-gel method. The Bi-CCE was applied to the determination of syringic acid by square wave adsorptive stripping voltammetry. The electrochemical properties of the Bi-CCE and the voltammetric response to syringic acid were investigated by cyclic voltammetry. The effects of the pH value of supporting electrolyte, of accumulation potential, accumulation time, SW mode parameters, and of possible interferents were tested. Under optimized conditions, the oxidation peak current (best measured at 0.8 V vs Ag/AgCl after an accumulation time of 20 s) increases linearly in the 0.4 to 24 μmol·L?1 syringic acid concentration range. Other figures of merit include an LOD of 47 nmol·L?1, a sensitivity of 3.3 μA·μmol?1·L·cm?2, and a relative standard deviation of 4.7% (for n = 5) at 2 μmol·L?1 of syringic acid. The method was successfully applied to the determination of syringic acid in red, white and rose wine as well as water samples.
Graphical abstract Schematic presentation of the preparation of carbon ceramic electrode (CCE) containing Bi2O3 nanoparticles and its application in square wave adsorptive stripping voltammetric (SW AdSV) determination of syringic acid.
  相似文献   
303.
The activity concentration of an 88Y solution was measured by means of a new custom-built 4πβ(LS)-γ coincidence counting system. Efficiency variation was carried out using chemical quenching and neutral density filters. A relative uncertainty of 0.57% was obtained for the activity concentration. Details of the measurements and of the analysis, as well as possibilities to reduce the uncertainty are discussed. Additional validation measurements were carried out by means of the well-established coincidence counting technique using a proportional counter (PC) in the β channel. The results of both coincidence methods were found to be in excellent agreement.  相似文献   
304.
H2O2 is a versatile chemical and can be generated by the oxygen reduction reaction (ORR) in proton donor solution in molecular solvents or room temperature ionic liquids (IL). We investigated this reaction at interfaces formed by eleven hydrophobic ILs and acidic aqueous solution as a proton source with decamethylferrocene (DMFc) as an electron donor. H2O2 is generated in colorimetrically detectable amounts in biphasic systems formed by alkyl imidazolium hexafluorophosphate or tetraalkylammonium bis(trifluoromethylsulfonyl)imide ionic liquids. H2O2 fluxes were estimated close to liquid|liquid interface by scanning electrochemical microscopy (SECM). Contrary to the interfaces formed by hydrophobic electrolyte solution in a molecular solvent, H2O2 generation is followed by cation expulsion to the aqueous phase. Weak correlation between the H2O2 flux and the difference between DMFc/DMFc+ redox potential and 2 electron ORR standard potential indicates kinetic control of the reaction.  相似文献   
305.
Task‐specific ionic liquid‐based ultrasound‐assisted dispersive liquid–liquid microextraction was used for the preconcentration of cadmium(II), cobalt(II), and lead(II) ions in tea samples, which were subsequently analyzed by liquid chromatography with UV detection. The proposed method of preconcentration is free of volatile organic compounds, which are often used as extractants and dispersing solvents in classic techniques of microextraction. A task‐specific ionic liquid trioctylmethylammonium thiosalicylate was used as an extractant and a chelating agent. Ultrasound was used to disperse the ionic liquid. After microextraction, the phases were separated by centrifugation, and the ionic liquid phase was solubilized in methanol and directly injected into the liquid chromatograph. Selected microextraction parameters, such as the volume of ionic liquid, the pH of the sample, the duration of ultrasound treatment, the speed and time of centrifugation, and the effect of ionic strength, were optimized. Under optimal conditions an enrichment factor of 200 was obtained for each analyte. The limits of detection were 0.002 mg/kg for Cd(II), 0.009 mg/kg for Co(II), and 0.013 mg/kg for Pb(II). The accuracy of the proposed method was evaluated by an analysis of the Certified Reference Materials (INCT‐TL‐1, INCT‐MPH‐2) with the recovery values in the range of 90–104%.  相似文献   
306.
The composition of wine is determined by a complex interaction between environmental factors, genetic factors (i.e., grape varieties), and winemaking practices (including technology and storage). Metabolomics using NMR spectroscopy, GC-MS, and/or LC-MS has shown to be a useful approach for assessing the origin, authenticity, and quality of various wines. Nonetheless, the use of additional analytical techniques with complementary separation mechanisms may aid in the deeper understanding of wine's metabolic processes. In this study, we demonstrate that CE-MS is a very suitable approach for the efficient profiling of polar ionogenic metabolites in wines. Without using any sample preparation or derivatization, wine was analyzed using a 10-min CE-MS workflow with interday RSD values for 31 polar and charged metabolites below 3.8% and 23% for migration times and peak areas, respectively. The utility of this workflow for the global profiling of polar ionogenic metabolites in wine was evaluated by analyzing different cool-climate Polish wine samples.  相似文献   
307.
308.
309.
In this theoretical study, we report on the molecular electrostatic potential (MEP) of titled molecules confined by repulsive potentials of cylindrical symmetry mimicking a topology. Our calculations show that the spatial restriction significantly changes the picture of the MEP of molecules in a quantitative and qualitative sense. In particular, the drastic changes in the MEP as a function of the strength of spatial confinement are observed for the BrCN molecule. This preliminary study is the first step in the investigation of the behavior of the MEP of molecular systems under orbital compression.  相似文献   
310.
Future food supply will become increasingly dependent on edible material extracted from insects. The growing popularity of artisanal food products enhanced by insect proteins creates particular needs for establishing effective methods for quality control. This study focuses on developing rapid and efficient on-site quantitative analysis of protein content in handcrafted insect bars by miniaturized near-infrared (NIR) spectrometers. Benchtop (Büchi NIRFlex N-500) and three miniaturized (MicroNIR 1700 ES, Tellspec Enterprise Sensor and SCiO Sensor) in hyphenation to partial least squares regression (PLSR) and Gaussian process regression (GPR) calibration methods and data fusion concept were evaluated via test-set validation in performance of protein content analysis. These NIR spectrometers markedly differ by technical principles, operational characteristics and cost-effectiveness. In the non-destructive analysis of intact bars, the root mean square error of cross prediction (RMSEP) values were 0.611% (benchtop) and 0.545–0.659% (miniaturized) with PLSR, and 0.506% (benchtop) and 0.482–0.580% (miniaturized) with GPR calibration, while the analyzed total protein content was 19.3–23.0%. For milled samples, with PLSR the RMSEP values improved to 0.210% for benchtop spectrometer but remained in the inferior range of 0.525–0.571% for the miniaturized ones. GPR calibration improved the predictive performance of the miniaturized spectrometers, with RMSEP values of 0.230% (MicroNIR 1700 ES), 0.326% (Tellspec) and 0.338% (SCiO). Furthermore, Tellspec and SCiO sensors are consumer-oriented devices, and their combined use for enhanced performance remains a viable economical choice. With GPR calibration and test-set validation performed for fused (Tellspec + SCiO) data, the RMSEP values were improved to 0.517% (in the analysis of intact samples) and 0.295% (for milled samples).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号