A new and green method for the synthesis of α,β-unsaturated arylsulfones had been achieved through the condensation of aromatic aldehydes,chloroacetonitrile,benzenesulfinic acid sodium salt in the presence of l-butyl-3-methyl imidazolium hydroxide([bmim]OH) in EtOH under reflux.The ionic liquid was recovered and recycled for subsequent reactions.The advantages of this protocol were non-toxic,easy work-up and good yields. 相似文献
A new preparative column for the vortex counter-current chromatograph was fabricated by making many (966) cylindrical separation units to a high-density polyethylene disk and then threading them with 6–40 taps. The resulting column had a total capacity of 364 mL. The performance of this vortex column was examined with three different two-phase solvent systems each using a set of suitable test samples: hexane–ethyl acetate–methanol–0.1 M hydrochloric acid (1:1:1:1, v/v) for the separation of DNP-amino acids; 1-butanol–acetic acid–water (4:1:5, v/v) for the separation of dipeptides; and hexane–acetonitrile–water (20:15:2, v/v) for the separation of Sudan dyes. Most of the separations show high partition efficiency of over a thousand theoretical plates, as expected based on the results previously obtained in preliminary separations with a small column. Overall, the results of the present study suggest that further improvement of the partition efficiency can be obtained by the modifying column configuration.
In this paper,we derive an elementary identity for smooth solutions of the following equation:△u(x) K(x)e^2u(x)=0 in R^2 and use it to get some global properties of the solutions. 相似文献
ECR离子源的等离子体阻抗对其微波传输与阻抗匹配设计至关重要。在中国科学院近代物理研究所现有的2.45 GHz ECR 质子源上,对等离子体阻抗进行了测量。首先用水吸收负载代替等离子体负载测量得到了所用微波窗阻抗,然后根据质子源测量数据,推算得到了等离子体阻抗。实验结果表明,脊波导输出端阻抗与后续负载不完全匹配,等离子体阻抗随微波功率变化呈非线性。这些结果为ECR离子源过渡匹配和微波窗的设计提供了参考依据。Plasma impedance of an ECR ion source is important for microwave transmission and impedance matching design. Plasma impedance was measured indirectly with the 2.45 GHz ECR proton source at the Institute of Modern Physics, Chinese Academy of Sciences. In the test, we got microwave window mpedance by using water absorption load instead of plasma load, and the source plasma impedance was derived from the test data with the 2.45 GHz ECR proton source and microwave window impedance. The experimental results show that ridge waveguide output impedance and the subsequent load does not exactly match, plasma impedance variation is nonlinear with microwave power. The achievedresult is useful in the design of ridged waveguide and microwave window. 相似文献