全文获取类型
收费全文 | 65篇 |
免费 | 1篇 |
专业分类
化学 | 26篇 |
力学 | 1篇 |
数学 | 2篇 |
物理学 | 37篇 |
出版年
2019年 | 2篇 |
2018年 | 1篇 |
2013年 | 2篇 |
2012年 | 1篇 |
2011年 | 1篇 |
2010年 | 1篇 |
2008年 | 1篇 |
2007年 | 2篇 |
2005年 | 4篇 |
2004年 | 1篇 |
2003年 | 1篇 |
2002年 | 3篇 |
2001年 | 1篇 |
2000年 | 5篇 |
1999年 | 6篇 |
1998年 | 1篇 |
1996年 | 1篇 |
1994年 | 4篇 |
1993年 | 2篇 |
1992年 | 7篇 |
1991年 | 2篇 |
1990年 | 2篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1987年 | 2篇 |
1986年 | 4篇 |
1985年 | 4篇 |
1980年 | 1篇 |
1975年 | 1篇 |
排序方式: 共有66条查询结果,搜索用时 15 毫秒
41.
In this paper the exact solution of the non-symmetric matrixRiccati equation with analytic coefficients is approximatedby a rational matrix function with a prefixed accuracy. Thisrational matrix function is locally defined as the exact solutionof a Riccati problem with matrix polynomial coefficients obtainedby truncation of the Taylor expansions of the matrix coefficientsof the original problem. 相似文献
42.
This paper presents a numerical method for solving the two‐dimensional unsteady incompressible Navier–Stokes equations in a vorticity–velocity formulation. The method is applicable for simulating the nonlinear wave interaction in a two‐dimensional boundary layer flow. It is based on combined compact difference schemes of up to 12th order for discretization of the spatial derivatives on equidistant grids and a fourth‐order five‐ to six‐alternating‐stage Runge–Kutta method for temporal integration. The spatial and temporal schemes are optimized together for the first derivative in a downstream direction to achieve a better spectral resolution. In this method, the dispersion and dissipation errors have been minimized to simulate physical waves accurately. At the same time, the schemes can efficiently suppress numerical grid‐mesh oscillations. The results of test calculations on coarse grids are in good agreement with the linear stability theory and comparable with other works. The accuracy and the efficiency of the current code indicate its potential to be extended to three‐dimensional cases in which full boundary layer transition happens. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
43.
44.
Terence Davis Matthew C Dix Michal J Rokicki Amy JC Brook Caroline S Widdowson David Kipling Mark C Bagley 《Chemistry Central journal》2011,5(1):1-5
To develop more potent small molecules with enhanced free radical scavenger properties, a series of N-substituted isatin derivatives was synthesized, and the cytoprotective effect on the apoptosis of PC12 cells induced by H2O2 was screened. All these compounds were found to be active, and N-ethyl isatin was found with the most potent activity of 69.7% protective effect on PC12 cells. Structure-activity relationship analyses showed the bioactivity of N-alkyl isatins decline as the increasing of the chain of the alkyl group, furthermore odd-even effect was found in the activity, which is interesting for further investigation. 相似文献
45.
Michael A. Jeannot Andrzej Przyjazny John M. Kokosa 《Journal of chromatography. A》2010,1217(16):2326-2336
Single drop microextraction (SDME) has emerged over the last 10–15 years as one of the simplest and most easily implemented forms of micro-scale sample cleanup and preconcentration. In the most common arrangement, an ordinary chromatography syringe is used to suspend microliter quantities of extracting solvent either directly immersed in the sample, or in the headspace above the sample. The same syringe is then used to introduce the solvent and extracted analytes into the chromatography system for identification and/or quantitation. This review article summarizes the historical development and various modes of the technique, some theoretical and practical aspects, recent trends and selected applications. 相似文献
46.
47.
48.
Maroua Ben Haddada Katy Jeannot Jolanda Spadavecchia 《Particle & Particle Systems Characterization》2019,36(2)
Doxycycline (DOXY) is a tetracycline antibiotic with a potent antibacterial activity against a wide variety of bacteria. One potential strategy to enhance the penetration and the antibacterial activity of antibiotics is the use of nanotechnology. In this work, an innovative synthesis of stable PEGylated‐gold nanoparticles (PEG‐AuNPs) loaded with DOXY is reported. As far as it is known, this is the first report on the combination of DOXY with AuNPs as polymeric complex. The obtained nanoparticles are fully characterized by transmission electron microscopy, dynamic light scattering, zeta‐potential, and UV–vis and Raman spectroscopy. The stability and sustained activity of the drug in nanoparticles is determined on a panel of Gram‐positive and Gram‐negative bacteria in comparison with the native form of the drug. This combined therapeutic agent restores the susceptibility of DOXY and shows an antibacterial activity against major human pathogens. 相似文献
49.
The relative rates of H-transfer between partners in ion-neutral complexes were compared with those in intramolecular rearrangements using results of first differential photoionization mass spectrometry measurements. Complex-mediated H-transfers are inferred to have rates of the same order as those for intramolecular hydrogen rearrangements, suggesting a similar range of motion of the reactive sites in both types of reactions. It is also concluded that at their fastest H-transfers take place between the partners in ion-neutral complexes within at most the time of several rotations of the partners in the complexes. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
50.
Liquid chromatography with photodiode array detection (LC-DAD) and liquid chromatography with mass spectrometry (LC-MS) are two techniques that have been widely used in monitoring pesticides and their degradation products in the environment. However, the application of liquid chromatography with tandem mass spectrometry (LC-MS-MS) for such purposes, once considered too costly, is now gaining considerable ground. In this study, we compare these methods for the multi-residue analysis of pesticides in surface waters collected from the central and southeastern regions of France, and from the St. Lawrence River in Canada. Forty-eight pesticides belonging to eight different classes (triazine, amide, phenylurea, triazole, triazinone, benzimidazole, morpholine, phenoxyalkanoic), along with some of their degradation products, were monitored on a regular basis in the surface waters. For LC-MS, we used the electrospray ionization (ESI) interface in the negative ionization mode on acidic pesticides (phenoxyalkanoic, sulfonylurea), and the atmospheric pressure chemical ionization (APCI) interface in the positive ionization mode on the remaining chemicals. Different extraction techniques were employed, including liquid-liquid extraction with dichloromethane, and solid-phase extraction using C18-bonded silica and graphitized carbon black cartridges. Eleven of the target chemicals (desethylatrazine, desisopropylatrazine, atrazine, simazine, terbuthylazine, metolachlor, carbendazime, bentazone, penconazole, diuron and isoproturon) were detected by LC-MS at concentrations ranging from 20 to 900 ng/l in the surface waters from France, and six pesticides (atrazine, desethylatrazine, desisopropylatrazine, cyanazine, simazine and metolachlor) were detected by LC-MS and LC-MS-MS at concentrations ranging from 3 to 52 ng/l in the samples drawn from the St. Lawrence River. There was good correlation between the LC-DAD and LC-MS techniques for 60 samples. The slope of the curves expressing the relationship between the results obtained with LC-DAD versus those obtained by LC-MS was near 1, with a correlation coefficient (r) of over 0.93. The identification potential of the LC-MS technique, however, was greater than that of the LC-DAD; its mass spectra, mainly reflecting the pseudomolecular ion resulting from a protonation or a deprotonation of the molecule, was rich in information. The LC-MS-MS technique with ion trap detectors, tested against the LC-MS on 10 surface water samples, gave results that correlated well with the LC-MS results, albeit generating mass spectra that yielded far more information about the structure of unknown substances. The sensitivity of the LC-MS-MS was equivalent to the selected ion monitoring (SIM) acquisition mode in LC-MS. The detection limits of the target pesticides ranged from 20 to 100 ng/l for the LC-MS technique (under full scan acquisition), and from 2 to 6 ng/l for LC-MS-MS. These limits were improved by a factor of almost 10 by increasing the sample volume to 10 l. 相似文献