全文获取类型
收费全文 | 87篇 |
免费 | 0篇 |
专业分类
化学 | 22篇 |
数学 | 1篇 |
物理学 | 64篇 |
出版年
2022年 | 1篇 |
2019年 | 2篇 |
2016年 | 1篇 |
2014年 | 2篇 |
2013年 | 5篇 |
2012年 | 4篇 |
2011年 | 1篇 |
2009年 | 1篇 |
2008年 | 5篇 |
2007年 | 4篇 |
2006年 | 4篇 |
2005年 | 5篇 |
2004年 | 3篇 |
2003年 | 1篇 |
2001年 | 2篇 |
2000年 | 3篇 |
1999年 | 2篇 |
1998年 | 1篇 |
1996年 | 3篇 |
1995年 | 2篇 |
1994年 | 8篇 |
1993年 | 10篇 |
1992年 | 6篇 |
1991年 | 4篇 |
1989年 | 2篇 |
1986年 | 2篇 |
1985年 | 1篇 |
1982年 | 1篇 |
1976年 | 1篇 |
排序方式: 共有87条查询结果,搜索用时 9 毫秒
21.
22.
23.
24.
Lifetime of levels up to 22+, have been measured in 78Kr and an oblate shape is assigned to the ground state using the CSM and the configuration dependent shell correction calculations.
Calculations further show that 78Kr is highly γ-soft nucleus. The experimental Q
t values coupled with theoretical calculations indicate an oblate shape for 78Kr at low spins and triaxial shape at higher spins 相似文献
25.
26.
27.
28.
Double quantum dots offer unique possibilities for the study of many-body correlations. A system containing one Kondo dot and one effectively noninteracting dot maps onto a single-impurity Anderson model with a structured (nonconstant) density of states. Numerical renormalization-group calculations show that, while band filtering through the resonant dot splits the Kondo resonance, the singlet ground state is robust. The system can also be continuously tuned to create a pseudogapped density of states and access a quantum-critical point separating Kondo and non-Kondo phases. 相似文献
29.
KM Clauwaert Van Bocxlaer JF HJ Major JA Claereboudt WE Lambert Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
30.
Stable isotope methods are potentially quite useful for validating natural or enhanced mineral degradation of contaminants. For this reason, a continuous flow gas chromatograph (GC), isotope ratio mass spectrometer (IRMS) has been coupled with a quadrupole mass selective detector (MSD) to allow simultaneous mass spectral and stable carbon isotope ratio data to be obtained from a single chromatographic analysis. This allows the target contaminant and any extra-cellular degradation intermediates to be both qualified and quantified. Previously acceptable limits of precision (0.3 parts per mil) are undesirable given the small fractionation observed during aerobic degradation. To further understand the fate of organic contaminants and to gain information about the metabolic degradative pathway employed by a microorganism, routine isotopic analyses on a range of analytes have been performed. Quantities of sample producing mass-44 ion beam signal (I(44)) of 2 x 10(-10) to 1 x 10(-8) A were analysed. When the IRMS was tuned for high sensitivity, ion source nonlinearities were overcome by peak height correction from an algorithm that was produced using known isotopic standards of varying concentrations. This led to sample accuracy of <0.01 per thousand and sample precision of 0.1 per thousand. Copyright 1999 John Wiley & Sons, Ltd. 相似文献