全文获取类型
收费全文 | 264篇 |
免费 | 2篇 |
专业分类
化学 | 174篇 |
晶体学 | 1篇 |
数学 | 6篇 |
物理学 | 85篇 |
出版年
2023年 | 1篇 |
2016年 | 2篇 |
2015年 | 2篇 |
2014年 | 1篇 |
2013年 | 4篇 |
2012年 | 12篇 |
2011年 | 17篇 |
2010年 | 15篇 |
2009年 | 8篇 |
2008年 | 26篇 |
2007年 | 22篇 |
2006年 | 30篇 |
2005年 | 35篇 |
2004年 | 14篇 |
2003年 | 12篇 |
2002年 | 12篇 |
2001年 | 8篇 |
2000年 | 6篇 |
1999年 | 9篇 |
1998年 | 3篇 |
1997年 | 6篇 |
1996年 | 1篇 |
1994年 | 3篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1990年 | 3篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1987年 | 1篇 |
1984年 | 1篇 |
1980年 | 1篇 |
1978年 | 2篇 |
1976年 | 1篇 |
1975年 | 1篇 |
排序方式: 共有266条查询结果,搜索用时 15 毫秒
21.
Szabolcs Fekete Jean-Luc Veuthey Sebastiaan Eeltink Davy Guillarme 《Analytical and bioanalytical chemistry》2013,405(10):3137-3151
Various recent wide-pore reversed-phase stationary phases were studied for the analysis of intact monoclonal antibodies (mAbs) of 150 kDa and their fragments possessing sizes between 25 and 50 kDa. Different types of column technology were evaluated, namely, a prototype silica-based inorganic monolith containing mesopores of ~250 Å and macropores of ~?1.1 μm, a column packed with 3.6 μm wide-pore core-shell particles possessing a wide pore size distribution with an average around 200 Å and a column packed with fully porous 1.7 μm particles having pore size of ~300 Å. The performance of these wide-pore materials was compared with that of a poly(styrene–divinyl benzene) organic monolithic column, with a macropore size of approximately 1 μm but without mesopores (stagnant pores). A systematic investigation was carried out using model IgG1 and IgG2 mAbs, namely rituximab, panitumumab, and bevacizumab. Firstly, the recoveries of intact and reduced mAbs were compared on the two monolithic phases, and it appeared that adsorption was less pronounced on the organic monolith, probably due to the difference in chemistry (C18 versus phenyl) and the absence of mesopores (stagnant zones). Secondly, the kinetic performance was investigated in gradient elution mode for all columns. For this purpose, peak capacities per meter as well as peak capacities per time unit and per pressure unit (PPT) were calculated at various flow rates, to compare performance of columns with different dimensions. In terms of peak capacity per meter, the core-shell 3.6 μm and fully porous 1.7 μm columns outperformed the two monolithic phases, at a temperature of 60 °C. However, when considering the PPT values, the core-shell 3.6 μm column remained the best phase while the prototype silica-based monoliths became very interesting, mostly due to a very high permeability compared with the organic monolith. Therefore, these core-shell and silica-based monolith provided the fastest achievable separation. Finally, at the maximal working temperature of each column, the core-shell 3.6 μm column was far better than the other one, because it is the only one stable up to 90 °C. Lastly, the loading capacity was also measured on these four different phases. It appeared that the organic monolith was the less interesting and rapidly overloaded, due to the absence of mesopores. On the other hand, the loading capacity of prototype silica-based monolith was indeed reasonable. 相似文献
22.
Candice Grivel Jean-Louis Rocca Davy Guillarme Jean-Luc Veuthey Sabine Heinisch 《Journal of chromatography. A》2010,1217(4):459-472
Reversed phase gradient elution is the method of choice for pharmaceuticals analysis since it allows reducing the analysis time while improving both the quality of the separation and the detection limits. The current trends are towards faster separations which can be achieved thanks to equipments withstanding ultra-high pressures and/or high temperatures. Under such conditions, gradient separations can be carried out within a few minutes or even a few tens of seconds. A long equilibration time in addition to the gradient time can be therefore very detrimental. In this work, we investigated the extent to which the gradient equilibration time can be reduced and which parameters mainly affect the retention variability of ionizable compounds when using volatile buffers. We first found out an excellent repeatability between run-to-run experiments whatever the equilibration time and the operating conditions. We then pointed out the key operating parameters which allow achieving reproducible runs when varying the equilibration time between runs. With a view of reducing the equilibration time, the effects of various conditions were examined. The latter include the type of additive for mobile phase pH adjustment, the initial eluent composition, the type of stationary phase, the temperature and the flow-rate. Although much remains to be understood about the equilibration process, our study allows making progress in the knowledge of this phenomenon. Based on the present results, a beneficial effect of both temperature and flow-rate was highlighted and operating conditions leading to faster column equilibration are suggested. 相似文献
23.
Jeanty G Wojciechowska A Marty JL Trojanowicz M 《Analytical and bioanalytical chemistry》2002,373(8):691-695
Determination of the organophosphorus pesticides paraoxon, chlorpyrifos oxon, and malaoxon has been performed by a method based on inhibition of acetylcholinesterase (AChE) and amperometric detection in a flow-injection system with enzymes obtained from the electric eel (eeAChE) and Drosophila melanogaster (dmAChE) and immobilized on the surface of platinum electrode within a layer of poly(vinyl alcohol) bearing styrylpyridinium groups. dmAChE is more sensitive than eeAChE to inhibition by chlorpyrifos oxon and paraoxon. The sensitivity difference was largest for chlorpyrifos oxon (detection limit approx. 17 times lower), and practically none for malaoxon. Determination of the analytes in spiked river water samples by use of the dmAChE biosensor resulted in recoveries from 50 to 90 % for chlorpyrifos oxon at levels of 20 to 40 nmol L(-1), 50 to 100 % for paraoxon at 0.6 to 0.8 micro mol L(-1), and 140 to 190 % for malaoxon at 0.6 to 1.2 micro mol L(-1). 相似文献
24.
Reversed phase high performance liquid chromatography (RPLC) is currently the method of choice for the analysis of basic compounds. However, with traditional silica materials, secondary interactions between the analyte and residual silanols produce peak tailing which can negatively affect resolution, sensitivity, and reproducibility. In order to reduce these secondary interactions, which comprise ion exchange, hydrogen bonding, and London forces interactions, chromatographic analyses can be carried out at low or high pH values where silanol groups and basic compounds are mostly uncharged. The chromatographic behaviour of a particular bidentate stationary phase, Zorbax Extend C18, was studied with a set of basic and neutral compounds. Thanks to a higher chemical stability than traditional silica based supports, analyses were carried out with a high pH mobile phase, which represents a good alternative to the acidic mobile phases generally used to reduce ion exchange interactions. The performance of this bidentate stationary phase was also compared with that of other supports and it was proved that it is advantageous to work with high pH mobile phases when analyzing basic compounds. 相似文献
25.
The stress-strain relations and the yield behavior of a model glass (a 80:20 binary Lennard-Jones mixture) is studied by means of molecular dynamics simulations. In a previous paper it was shown that, at temperatures below the glass transition temperature, Tg, the model exhibits shear banding under imposed shear. It was also suggested that this behavior is closely related to the existence of a (static) yield stress (under applied stress, the system does not flow until the stress sigma exceeds a threshold value sigmay). A thorough analysis of the static yield stress is presented via simulations under imposed stress. Furthermore, using steady shear simulations, the effect of physical aging, shear rate and temperature on the stress-strain relation is investigated. In particular, we find that the stress at the yield point (the "peak"-value of the stress-strain curve) exhibits a logarithmic dependence both on the imposed shear rate and on the "age" of the system in qualitative agreement with experiments on amorphous polymers, and on metallic glasses. In addition to the very observation of the yield stress which is an important feature seen in experiments on complex systems like pastes, dense colloidal suspensions and foams, further links between our model and soft glassy materials are found. An example is the existence of hysteresis loops in the system response to a varying imposed stress. Finally, we measure the static yield stress for our model and study its dependence on temperature. We find that for temperatures far below the mode coupling critical temperature of the model (Tc = 0.435 in Lennard-Jones units), sigmay decreases slowly upon heating followed by a stronger decrease as Tc is approached. We discuss the reliability of results on the static yield stress and give a criterion for its validity in terms of the time scales relevant to the problem. 相似文献
26.
Karine Vuignier Szabolcs Fekete Pierre‐Alain Carrupt Jean‐Luc Veuthey Davy Guillarme 《Journal of separation science》2013,36(14):2231-2243
In the present study, three types of silica‐based monoliths, i.e. the first and second generations of commercial silica monolithic columns and a wide‐pore prototype monolith were compared for the analysis of large biomolecules. These molecules possess molecular weights between 1 and 66 kDa. The gradient kinetic performance of the first‐generation monolith was lower than that of the second generation, for large biomolecules (>14 kDa) but very close with smaller ones (1.3–5.8 kDa). In contrast, the wide‐pore prototype column was particularly attractive with proteins larger than 19 kDa (higher peak capacity). Among these three columns, the selectivity and retention remained quite similar but a possible larger number of accessible and charged residual silanols was noticed on the wide‐pore prototype material, which led to unpredicted small changes in selectivity and slightly broader peaks than expected. The peak shapes attained with the addition of 0.1% formic acid in the mobile phase remained acceptable for MS coupling, particularly for biomolecules of less than 6 kDa. It was found that one of the major issues with all of these silica‐based monoliths is the possible poor recovery of large biomolecules (principally with monoclonal antibody fragments of more than 25 kDa). 相似文献
27.
Hrobarikova J Robert JL Calberg C Jérôme R Grandjean J 《Langmuir : the ACS journal of surfaces and colloids》2004,20(22):9828-9833
The structure and dynamics of surfactant and polymer chains in intercalated poly(epsilon-caprolactone)/clay nanocomposites are characterized by (31)P magic-angle spinning (MAS) and (13)C cross-polarization MAS NMR techniques. To obtain hybrid materials with the low polymer content required for this study, in situ intercalative polymerization was performed by adapting a published procedure. After nanocomposite formation, the chain motion of the surfactant is enhanced in the saponite-based materials but reduced in the Laponite ones. Compared to the starting clay, the trans conformer population of the surfactant hydrocarbon chain in the nanocomposite decreases for the saponite systems. Mobility of the polymer chain is higher in the nanocomposites than in the bulk phase. The charge of the modified saponite does not significantly influence chain mobility in the nanocomposites. 相似文献
28.
On-line combination of partial filling capillary electrophoresis and electrospray ionization mass spectrometry was demonstrated for the simultaneous enantioseparation of tramadol and its main phase I metabolites. The partial filling technique was efficient at avoiding MS contamination by the chiral selector. Different experimental factors were investigated, including the chiral selector nature and concentration, plug length as well as the separation temperature. The best enantioseparation of the investigated compounds was achieved with a coated polyvinyl alcohol capillary and a 40 mM ammonium acetate buffer, pH 4.0, adding sulfobutyl ether beta-cyclodextrin (2.5 mg/ml) as the chiral selector. The charged cyclodextrin not only allowed enantioseparation of tramadol and its metabolites, but also improved the selectivity of compounds with the same molecular mass. Finally, CE-electrospray ionisation-MS was successfully applied to the stereoselective analysis of tramadol and its main metabolites in plasma after a simple liquid-liquid extraction. 相似文献
29.
Aline Staub Sylvain Giraud Martial Saugy Serge Rudaz Jean‐Luc Veuthey Julie Schappler 《Electrophoresis》2010,31(2):388-395
CE is a powerful analytical tool used to separate intact biomolecules such as proteins. The coupling of CE with TOF/MS produces a very promising method that can be used to detect and identify proteins in different matrices. This paper describes an efficient, rapid, and simple CE‐ESI‐TOF/MS procedure for the analysis of endogenous human growth hormone and recombinant human growth hormone without sample preparation. Operational factors were optimized using an experimental design, and the method was successfully applied to distinguish human growth hormone and recombinant human growth hormone in unknown samples. 相似文献
30.