全文获取类型
收费全文 | 462篇 |
免费 | 29篇 |
国内免费 | 2篇 |
专业分类
化学 | 348篇 |
晶体学 | 4篇 |
力学 | 21篇 |
数学 | 43篇 |
物理学 | 77篇 |
出版年
2024年 | 5篇 |
2023年 | 8篇 |
2022年 | 30篇 |
2021年 | 44篇 |
2020年 | 29篇 |
2019年 | 23篇 |
2018年 | 25篇 |
2017年 | 16篇 |
2016年 | 30篇 |
2015年 | 14篇 |
2014年 | 18篇 |
2013年 | 41篇 |
2012年 | 39篇 |
2011年 | 41篇 |
2010年 | 31篇 |
2009年 | 18篇 |
2008年 | 15篇 |
2007年 | 20篇 |
2006年 | 14篇 |
2005年 | 9篇 |
2004年 | 5篇 |
2003年 | 8篇 |
2002年 | 1篇 |
2001年 | 2篇 |
1999年 | 1篇 |
1996年 | 2篇 |
1995年 | 1篇 |
1993年 | 1篇 |
1988年 | 1篇 |
1987年 | 1篇 |
排序方式: 共有493条查询结果,搜索用时 15 毫秒
201.
Zhang X Khimji I Gurkan UA Safaee H Catalano PN Keles HO Kayaalp E Demirci U 《Lab on a chip》2011,11(15):2535-2540
5.3 million American couples of reproductive age (9%) are affected by infertility, among which male factors account for up to 50% of cases, which necessitates the identification of parameters defining sperm quality, including sperm count and motility. In vitro fertilization (IVF) with or without intra cytoplasmic sperm injection (ICSI) has become the most widely used assisted reproductive technology (ART) in modern clinical practice to overcome male infertility challenges. One of the obstacles of IVF and ICSI lies in identifying and isolating the most motile and presumably healthiest sperm from semen samples that have low sperm counts (oligozoospermia) and/or low sperm motility (oligospermaesthenia). Microfluidic systems have shown potential to sort sperm with flow systems. However, the small field of view (FOV) of conventional microscopes commonly used to image sperm motion presents challenges in tracking a large number of sperm cells simultaneously. To address this challenge, we have integrated a lensless charge-coupled device (CCD) with a microfluidic chip to enable wide FOV and automatic recording as the sperm move inside a microfluidic channel. The integrated system enables the sorting and tracking of a population of sperm that have been placed in a microfluidic channel. This channel can be monitored in both horizontal and vertical configuration similar to a swim-up column method used clinically. Sperm motilities can be quantified by tracing the shadow paths for individual sperm. Moreover, as the sperm are sorted by swimming from the inlet towards the outlet of a microfluidic channel, motile sperm that reach the outlet can be extracted from the channel at the end of the process. This technology can lead to methods to evaluate each sperm individually in terms of motility response in a wide field of view, which could prove especially useful, when working with oligozoospermic or oligospermaesthenic samples, in which the most motile sperm need to be isolated from a pool of small number of sperm. 相似文献
202.
This paper described a new approach for the preconcentration of lead (Pb2+) by temperature controlled ionic liquid-dispersive liquid phase microextraction (TIL-DLME) prior to analyzing by flame atomic absorption spectrometry (FAAS). An ionic liquid (IL) 1-Butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] was used as an extractant solvent. The Pb2+ was complexed with ammonium pyrrolidinedithiocarbamate (APDC) and then entered into the infinite IL drops at high temperature (> 70 °C). Important variables affecting the microextraction efficiency such as pH, ligand concentration, amount of IL, temperature and incubation time were investigated. The results showed that the coexistent ions had no obvious negative effect on the determination of Pb2+. In the optimum experimental conditions, the limit of detection (LOD) and the enhancement factor (EF) were 0.13 μg L? 1 and 93, respectively. The relative standard deviation (RSD) of 10 μg L? 1 Pb2+ was 4.3%. The developed method was validated by determining Pb2+ in certified reference material (CRM) and the results showed that the determined values of Pb2+ were in good agreement with the certified value. The proposed method was applied satisfactorily for the preconcentration of Pb2+ in acid digested blood samples of children with different respiratory disorders. 相似文献
203.
Banerjee S Prasad P Hussain A Khan I Kondaiah P Chakravarty AR 《Chemical communications (Cambridge, England)》2012,48(62):7702-7704
Curcumin (Hcur) as a cellular imaging and PDT agent shows remarkable photocytotoxicity in HeLa cells in visible light of 400-700 nm giving IC(50) = 8.2 ± 0.2 μM and its degradation is arrested on formation of photocytotoxic dipyridophenazine (dppz) complex [VO(cur)(dppz)Cl] (IC(50) = 3.3 ± 0.4 μM), while both are less toxic in the dark. 相似文献
204.
Bakhat Ali Rashad Mehmood Uzma Rasheed Mughal Abdul Malik Muhammad Safder Riaz Hussain Muhammad Imran Rasool Bakhsh Tareen 《Helvetica chimica acta》2012,95(4):586-593
Eremosides A–C ( 1 – 3 ), three new iridoid glucosides, were isolated from the AcOEt‐soluble fraction of the EtOH extract of the whole plant of Eremostachys loasifolia, along with buddlejoside B ( 4 ), 10‐O‐benzoylcatalpol ( 5 ), and pakiside A ( 6 ) reported for the first time from this species. The structures of these compounds were elucidated by spectroscopic data including 2D‐NMR, FAB‐MS, ESI‐MS, as well as by acid and basic hydrolyses. 相似文献
205.
Hassan Imran Afridi Mohammad Khan Jamali Gul Hasan Kazi Mohammad Bilal Arain Nusrat Jalbani 《光谱学快报》2013,46(2):203-214
The abnormal metabolism of metal ions plays an important role in health and disease conditions, and studies about them have been attracting significant interest. The aim of our study was to assess the heavy metals (cadmium, copper, iron, nickel, chromium, lead, and zinc) in scalp hair samples of 200 hypertensive (HT) patients of an urban population together with 215 non‐hypertensive male subjects in the age group of 30–60 years. Hair samples were digested with conventional wet ashing and microwave digestion. Analyses of both digests were done by flame and graphite furnace atomic absorption spectrometry. The validity of methodology was checked by use of the certified reference material (CRM 397) hair, provided the Community Bureau of Reference, Commission of the European Communities. According to a statistical evaluation of the results, the microwave digestion method was a valid alternative to the conventional acid digestion method, p value >0.05, but it gave a faster digestion. The overall metal recoveries were 96–98% of those obtained with microwave digestion. Among the toxic elements determined, levels of nickel, cadmium, copper, chromium, and lead in scalp hair samples of hypertensive patients were significantly higher compared normal male subjects, whereas the essential elements such as iron and zinc were found to be low compared age‐matched non‐hypertensive subjects. 相似文献
206.
207.
We give an upper bound for the Stanley depth of the edge ideal of a complete k-partite hypergraph and as an application we give an upper bound for the Stanley depth of a monomial ideal in a polynomial ring S. We also give a lower and an upper bound for the cyclic module S/I associated to the complete k-partite hypergraph. 相似文献
208.
For a square-free monomial ideal I ? S = k[x 1, x 2,…, x n ], we introduce the notion of quasi-linear quotients. By using the quasi-linear quotients, we give a new algebraic criterion for the shellability of a pure simplicial complex Δ over [n]. Also, we provide a new criterion for the Cohen–Macaulayness of the face ring of a pure simplicial complex Δ. Moreover, we show that the face ring of the spanning simplicial complex (defined in [2]) of an r-cyclic graph is Cohen–Macaulay. 相似文献
209.
In this paper we present two new numerically stable methods based on Haar and Legendre wavelets for one- and two-dimensional parabolic partial differential equations (PPDEs). This work is the extension of the earlier work , and from one- and two-dimensional boundary-value problems to one- and two- dimensional PPDEs. Two generic numerical algorithms are derived in two phases. In the first stage a numerical algorithm is derived by using Haar wavelets and then in the second stage Haar wavelets are replaced by Legendre wavelets in quest for better accuracy. In the proposed methods the time derivative is approximated by first order forward difference operator and space derivatives are approximated using Haar (Legendre) wavelets. Improved accuracy is obtained in the form of wavelets decomposition. The solution in this process is first obtained on a coarse grid and then refined towards higher accuracy in the high resolution space. Accuracy wise performance of the Legendre wavelets collocation method (LWCM) is better than the Haar wavelets collocation method (HWCM) for problems having smooth initial data or having no shock phenomena in the solution space. If sharp transitions exists in the solution space or if there is a discontinuity between initial and boundary conditions, LWCM loses its accuracy in such cases, whereas HWCM produces a stable solution in such cases as well. Contrary to the existing methods, the accuracy of both HWCM and LWCM do not degrade in case of Neumann’s boundary conditions. A distinctive feature of the proposed methods is its simple applicability for a variety of boundary conditions. Performances of both HWCM and LWCM are compared with the most recent methods reported in the literature. Numerical tests affirm better accuracy of the proposed methods for a range of benchmark problems. 相似文献
210.
This study describes a rapid and sensitive analytical method for the determination of amino acids in foods and drinks. The method entailed dilution or extraction of amino acids from foods using the mixture of acetonitrile and 0.1% aqueous formic acid (50:50, v/v). Chromatographic separation of underivatized amino acids was performed using a hydrophilic interaction liquid chromatography within a runtime of 6 min. Both hydrophobicity and charge of the side chain played important roles on the elution order of amino acids under the chromatographic conditions. High-resolution mass spectrometry allowed qualitative and quantitative detection of amino acids in complex food matrices. Its response was found linear over a concentration range of 0.25-10 μg/ml. The method could be successfully applied to various foods and drinks to profile individual amino acids. Mean percentage recoveries of amino acids from different matrices were 88.5% or higher with residual standard deviation of less than 5.0%. 相似文献