排序方式: 共有19条查询结果,搜索用时 31 毫秒
11.
12.
13.
14.
The capillary electrophoretic enantioseparation of rac-propranolol using cellobiohydrolase Tr Cel7A as selector was optimized by an unbiased statistical experimental design. A set of pre-experiments was performed in order to identify critical experimental factors. In the definitive chemometric design pH, ranging from 5 to 7, ionic strength ranging between 0.01 and 0.02 and organic solvent additive in concentration from 1 to 19% v/v were studied. The response surface plot revealed a separation optimum in the pH interval studied. When all parameters were taken into account, a background electrolyte consisting of 0.016 M bistris-acetate buffer with pH 6.5 and 17% v/v acetonitrile gave the optimum separation. The significance of the statistical design was confirmed by the generally good agreement obtained between predicted response and actual experimental data. 相似文献
15.
16.
Harang V Eriksson J Sänger-van de Griend CE Jacobsson SP Westerlund D 《Electrophoresis》2004,25(1):80-93
The separation of anionic, cationic and neutral drugs in microemulsion electrokinetic chromatography (MEEKC) was studied with a statistical experimental design. The concentration of sodium dodecyl sulfate (SDS, surfactant), 1-butanol (co-surfactant) and borate buffer and the factors Brij 35 (surfactant), 2-propanol (organic solvent) and cassette temperature were varied simultaneously, while the parameters pH (9.2), the concentration of octane (oil, 0.8% w/w), the voltage (10 kV) and the dimension of the fused-silica capillary, were kept constant. Eight different model substances were chosen with different hydrophobicities. Two of the analytes were positively charged, two were negatively charged, and the remaining four were neutral or close to neutral at the pH explored. The importance of each parameter on the separation window, the plate height and the retention factor for each of the analytes was studied by means of multiple linear regression (MLR) models. A new response was evaluated for anions, the quotient between the effective mobility in the microemulsion and the effective mobility in the corresponding buffer. Factors affecting selectivity changes were also explored, and it was found that SDS and 2-propanol had the largest effect on selectivity. 相似文献
17.
Determination of protein-ligand affinity constants from direct migration time in capillary electrophoresis 总被引:2,自引:0,他引:2
Nilsson M Harang V Bergström M Ohlson S Isaksson R Johansson G 《Electrophoresis》2004,25(12):1829-1836
A simple method to calculate dissociation constants for protein-ligand interactions by partial-filling capillary electrophoresis is demonstrated. The method uses raw migration time data for the ligand and needs only additional information about capillary inner radius and the absolute amount of protein loaded. A theoretical study supported by experimental data also demonstrates that the retention of analyte in affinity capillary electrophoresis (ACE) using the partial-filling technique depends linearly on the absolute amount of selector added but is independent of both selector zone length and selector mobility. Factors such as field strength and electroosmotic flow are also cancelled out if they are kept constant. The theory is confirmed and the usefulness of the method is demonstrated by enantioseparations using alpha-acid glycoprotein (AGP) and cellulase (Cel 7A) as chiral selectors. 相似文献
18.
19.