首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   175篇
  免费   14篇
  国内免费   4篇
化学   129篇
晶体学   5篇
力学   12篇
数学   10篇
物理学   37篇
  2022年   1篇
  2021年   4篇
  2020年   8篇
  2019年   9篇
  2018年   12篇
  2017年   9篇
  2016年   19篇
  2015年   10篇
  2014年   14篇
  2013年   27篇
  2012年   8篇
  2011年   13篇
  2010年   13篇
  2009年   8篇
  2008年   12篇
  2007年   3篇
  2006年   5篇
  2005年   5篇
  2004年   2篇
  2003年   2篇
  2002年   2篇
  1999年   3篇
  1997年   1篇
  1988年   1篇
  1980年   2篇
排序方式: 共有193条查询结果,搜索用时 15 毫秒
191.
A modified carbon paste electrode was constructed for the determination of dissolved oxygen using diamino‐o‐benzoquinone (DABQ) as the modifier. The electrochemical behavior of the electrode in citrate buffer (pH 2.0) was studied. In the presence of dissolved oxygen (DO) both cathodic and anodic peak currents decreased, indicating a chemical reaction between modifier and O2. The decrease in peak current was linearly proportional to the amount of dissolved oxygen in the concentration range of 252–1260 μM of DO. The electrode was utilized in the determination of DO in urine samples. The relative error and RSD of the method were 1.6% and 4.1%, respectively. The electrode was applied more than two months for the determination of DO without any significant divergence in its voltammetric response.  相似文献   
192.
A simple, sensitive and selective flotation method is described for the preconcentration and atomic absorption spectrometric determination of zinc ion in water and blood samples. At a solution pH of 5.2, 4-(2-pyridylazo-resorcinol) and Triton X-114 were used as hydrophobic ligand and non-ionic surfactant, respectively. The chemical variables affecting the preconcentration process were optimized. Under the optimized experimental conditions, the selective preconcentration and determination of as low zinc concentration as 6.5 μg L−1 can be made. The proposed method was successfully applied to the preconcentration and low-level determination of zinc in different water and blood serum samples.   相似文献   
193.
The polyethylene fibers containing Ag nanoparticles were prepared through the chemical reduction under ultrasound irradiation. The effect of reducing reagent, power of ultrasound irradiation, reaction time and temperature in growth of the nanometric Ag were studied. Particle sizes and morphology of nanoparticle are depending on power of ultrasound irradiation. Results show a decrease in the particles size as increasing power of ultrasound irradiation. Also, an increase in temperature led to increase of particle size. The polyethylene fibers containing Ag nanoparticles were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy (SEM).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号