排序方式: 共有64条查询结果,搜索用时 0 毫秒
11.
Capillary electrophoresis for the analysis of paralytic shellfish poisoning toxins in shellfish: Comparison of detection methods 下载免费PDF全文
Aemi S. Abdul Keyon Rosanne M. Guijt Andras Gaspar Artaches A. Kazarian Pavel N. Nesterenko Christopher J. Bolch Michael C. Breadmore 《Electrophoresis》2014,35(10):1496-1503
Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre‐ or postcolumn oxidation for fluorescence detection (HPLC‐FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on‐site monitoring. In this study, CE methods were developed for C4D, FLD, UV absorption detection, and MS—making this first report of C4D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE‐UV and CZE‐C4D methods provide better resolution, selectivity, and separation efficiency compared to CZE‐MS and MEKC‐FLD. The sensitivity of the CZE‐C4D and MEKC‐FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE‐C4D and 60.9 to 104 ng/mL for MEKC‐FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE‐C4D and MEKC‐FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE‐C4D method suffered from significant interferences from the shellfish matrix, MEKC‐FLD was successfully used for PST screening of a periodate‐oxidized mussel sample, with results confirmed by HPLC‐FLD. This confirms the potential of MEKC‐FLD for screening of PSTs in shellfish samples. 相似文献
12.
13.
A UV light emitting diode (LED) with a maximum output of 372 nm was collimated using a pinhole and a small plastic tube and focused using a microscope objective onto a substrate for direct lithographic patterning of the photoresist. Movement of the substrate with a motorised linear stage (syringe pump) allowed lines in SU-8 to be pattered with a width down to 35 microm at a linear velocity of 80 microm s(-1), while in the dry film resist Ordyl SY 330, features as narrow as 17 microm were made at a linear velocity of 245 microm s(-1). At this linear velocity, a 75 mm long feature could be patterned in 5 min. Functional microfluidic devices were made by casting PDMS on a master made by LED lithography. The results show that UV LEDs are a suitable light source for direct writing lithography, offering a budget friendly, and high resolution alternative for rapid prototyping of features smaller than 20 microm. 相似文献
14.
C McConville RM Kalin D Flood 《Rapid communications in mass spectrometry : RCM》1999,13(13):1339-1345
Current methods for stable oxygen isotopic (delta (18)O) analysis of soil water rely on separation of water from the soil matrix before analysis. These separation procedures are not only time consuming and require relatively large samples of soil, but also have been shown to introduce a large potential source of error. Current research at Queen's University Belfast is focused on using direct equilibration of CO(2) with the pore water to eliminate this extraction step using the automated Multiprep system and a Micromass Prism III isotope ratio mass spectrometer (IRMS). The findings of this research indicate the method is less time consuming, more reliable, and reproducible to within accepted limits (+/-0.1% per thousand delta (18)O). In this study the direct equilibration method is used to analyse delta (18)O tracer profiles in the unsaturated zone of field soils, concurrently with chloride tracer profiles, which can be used to assess infiltration rates and mechanisms through the unsaturated zone. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
15.
V. Vijayasundaram V. Ramasamy PL. RM. Palaniappan 《Journal of Thermal Analysis and Calorimetry》2009,98(1):183-188
The paper presents the changes in the thermal properties of control, arsenic exposed and DMSA treated Labeo rohita bones by using thermo analytical techniques. The result shows that the mass loss due to the thermal decomposition occurs
in three distinct steps due to loss of water, organic and inorganic materials. The arsenic exposed bones present a different
thermal behaviour compared to the control bones. The residue masses are increased due to arsenic exposure, while the DMSA
treatment reduces the residue mass level. These thermal characteristics can be used as a qualitative method to check the metal
accumulation in samples. 相似文献
16.
Berthold A Laugere F Schellevis H de Boer CR Laros M Guijt RM Sarro PM Vellekoop MJ 《Electrophoresis》2002,23(20):3511-3519
Glass microdevices for capillary electrophoresis (CE) gained a lot of interest in the development of micrototal analysis systems (microTAS). The fabrication of a microTAS requires integration of sampling, chemical separation and detection systems into a microdevice. The integration of a detection system into a microchannel, however, is hampered by the lack of suitable microfabrication technology. Here, a microfabrication method for integration of insulated microelectrodes inside a leakage-free microchannel in glass is presented. A combination of newly developed technological approaches, such as low-temperature glass-to-glass anodic bonding, channel etching, fabrication of buried metal interconnects, and deposition of thin plasma-enhanced chemical vapour deposition (PECVD) silicon carbide layers, enables the fabrication of a CE microdevice with an integrated contactless conductivity detector. The fabrication method of this CE microdevice with integrated contactless conductivity detector is described in detail. Standard CE separations of three inorganic cations in concentrations down to 5 microM show the viability of the new microCE system. 相似文献
17.
The O‐allylation of bisphenol A (BPA) has been performed with the most selective catalysts for O‐allylation of phenols reported previously. Both the cyclopentadienyl–ruthenium catalysts and the palladium–diphosphine catalysts are capable of selectively performing single and double O‐allylation of BPA. An intriguing solvent effect is observed; the choice of the solvent is of key importance for both conversion and selectivity. The use of an excess of diallyl ether as allylating agent results in relatively high yields of the bisallyl ether of bisphenol A, while maintaining the high selectivity for O‐allylation. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
18.
Dr. Ibraam E. Mikhail Dr. Masoomeh Tehranirokh Dr. Andrew A. Gooley Prof. Rosanne M. Guijt Prof. Michael C. Breadmore 《Angewandte Chemie (Weinheim an der Bergstrasse, Germany)》2020,132(51):23362-23368
Here, an electrokinetic extraction (EkE) syringe is presented allowing for on-line electrokinetic removal of serum proteins before ESI-MS. The proposed concept is demonstrated by the determination of pharmaceuticals from human serum within minutes, with sample preparation limited to a 5× dilution of the sample in the background electrolyte (BGE) and application of voltage, both of which can be performed in-syringe. Signal enhancements of 3.6–32 fold relative to direct infusion of diluted serum and up to 10.8 fold enhancement, were obtained for basic and acidic pharmaceuticals, respectively. Linear correlations for the basic drugs by EkE-ESI-MS/MS were achieved, covering the necessary clinical range with LOQs of 5.3, 7.8, 6.1, and 17.8 ng mL−1 for clomipramine, chlorphenamine, pindolol, and atenolol, respectively. For the acidic drugs, the EkE-ESI-MS LOQs were 3.1 μg mL−1 and 2.9 μg mL−1 for naproxen and paracetamol, respectively. The EkE-ESI-MS and EkE-ESI-MS/MS methods showed good accuracy (%found of 81 % to 120 %), precision (≤20 %), and linearity (r>0.997) for all the studied drugs in spiked serum samples. 相似文献
19.
Md Fokhrul Islam Yiing C. Yap Feng Li Rosanne M. Guijt Michael C. Breadmore 《Electrophoresis》2020,41(23):2007-2014
A three-dimensional-printed microfluidic device made of a thermoplastic material was used to study the creation of molecular filters by controlled dielectric breakdown. The device was made from acrylonitrile butadiene styrene by a fused deposition modeling three-dimensional printer and consisted of two V-shaped sample compartments separated by 750 µm of extruded plastic gap. Nanofractures were formed in the thin piece of acrylonitrile butadiene styrene by controlled dielectric breakdown by application voltage of 15–20 kV with the voltage terminated when reaching a defined current threshold. Variation of the size of the nanofractures was achieved by both variation of the current threshold and by variation of the ionic strength of the electrolyte used for breakdown. Electrophoretic transport of two proteins, R-phycoerythrin (RPE; <10 nm in size) and fluorescamine-labeled BSA (f-BSA; 2–4 nm), was used to monitor the size and transport properties of the nanofractures. Using 1 mM phosphate buffer, both RPE and f-BSA passed through the nanofractures when the current threshold was set to 25 µA. However, when the threshold was lowered to 10 µA or lower, RPE was restricted from moving through the nanofractures. When we increased the electrolyte concentration during breakdown from 1 to 10 mM phosphate buffer, BSA passed but RPE was blocked when the threshold was equal to, or lower than, 25 µA. This demonstrates that nanofracture size (pore area) is directly related to the breakdown current threshold but inversely related to the concentration of the electrolyte used for the breakdown process. 相似文献
20.
MK Bhide RM Kadam MD Sastry Ajay Singh Shashwati Sen Manmeet Kaur DK Aswal SK Gupta VC Sahni 《Pramana》2002,58(5-6):799-802
Microwave absorption studies have been carried out on MgB2 superconductor using a standard X-band EPR spectrometer. The modulated low-field microwave absorption signals recorded for
polycrystalline (grain size ∼ 10 μm) samples suggested the absence of weak-link character. The field dependent direct microwave