排序方式: 共有74条查询结果,搜索用时 15 毫秒
11.
Alves GA Amato S Anjos JC Appel JA Astorga J Bracker SB Cremaldi LM Darling CL Dixon RL Errede D Fenker HC Gay C Green DR Halling AM Jedicke R Karchin PE Kwan S Leuking LH Mantsch PM de Mello Neto JR Metheny J Milburn RH de Miranda JM da Motta Filho H Napier A Passmore D Rafatian A dos Reis AC Ross WR Santoro AF Sheaff M Souza MH Spalding WJ Stoughton C Streetman ME Summers DJ Takach SF Wallace A Wu Z 《Physical review D: Particles and fields》1994,49(9):R4317-R4320
12.
Alves GA Amato S Anjos JC Appel JA Bracker SB Cremaldi LM Darling CL Dixon RL Errede D Fenker HC Gay C Green DR Jedicke R Kaplan D Karchin PE Kwan S Leedom I Lueking LH Luste GJ Mantsch PM de Mello Neto JR Metheny J Milburn RH de Miranda JM da Motta Filho H Napier A Rafatian A dos Reis AC Reucroft S Ross WR Santoro AF Sheaff M Souza MH Spalding WJ Stoughton C Streetman ME Summers DJ Takach SF Wu Z 《Physical review letters》1993,70(6):722-725
13.
14.
Cletus A D'Souza Vikramjit Chopra Richard Varhol Yuan-Yun Xie Slavita Bohacec Yongjun Zhao Lisa LC Lee Mikhail Bilenky Elodie Portales-Casamar An He Wyeth W Wasserman Daniel Goldowitz Marco A Marra Robert A Holt Elizabeth M Simpson Steven JM Jones 《BMC neuroscience》2008,9(1):1-14
Background
We have recorded responses from single neurons in murine visual cortex to determine the effectiveness of the input from the two murine cone photoreceptor mechanisms and whether there is any unique selectivity for cone inputs at this higher region of the visual system that would support the possibility of colour vision in mice. Each eye was stimulated by diffuse light, either 370 (strong stimulus for the ultra-violet (UV) cone opsin) or 505 nm (exclusively stimulating the middle wavelength sensitive (M) cone opsin), obtained from light emitting diodes (LEDs) in the presence of a strong adapting light that suppressed the responses of rods.Results
Single cells responded to these diffuse stimuli in all areas of striate cortex. Two types of responsive cells were encountered. One type (135/323 – 42%) had little to no spontaneous activity and responded at either the on and/or the off phase of the light stimulus with a few impulses often of relatively large amplitude. A second type (166/323 – 51%) had spontaneous activity and responded tonically to light stimuli with impulses often of small amplitude. Most of the cells responded similarly to both spectral stimuli. A few (18/323 – 6%) responded strongly or exclusively to one or the other spectral stimulus and rarely in a spectrally opponent manner.Conclusion
Most cells in murine striate cortex receive excitatory inputs from both UV- and M-cones. A small fraction shows either strong selectivity for one or the other cone mechanism and occasionally cone opponent responses. Cells that could underlie chromatic contrast detection are present but extremely rare in murine striate cortex. 相似文献15.
Di Leonardo R Ruocco G Leach J Padgett MJ Wright AJ Girkin JM Burnham DR McGloin D 《Physical review letters》2007,99(1):010601
The Brownian dynamics of an optically trapped water droplet are investigated across the transition from over- to underdamped oscillations. The spectrum of position fluctuations evolves from a Lorentzian shape typical of overdamped systems (beads in liquid solvents) to a damped harmonic oscillator spectrum showing a resonance peak. In this later underdamped regime, we excite parametric resonance by periodically modulating the trapping power at twice the resonant frequency. The power spectra of position fluctuations are in excellent agreement with the obtained analytical solutions of a parametrically modulated Langevin equation. 相似文献
16.
Anthony JM Garrett 《Contemporary Physics》2013,54(2):163-165
The dynamic electronic structure of atoms and molecules can be directly observed by means of the (e, 2e) reaction, which measures the distribution of energies and momenta of two electrons in coincidence after a knockout reaction initiated by an electron beam of known momentum incident on a molecular gas target. The molecular state for each event is identified by the electron separation energy. The recoil momentum for each event is known from the difference of measured initial and final momenta. It has been verified that values of this momentum are equal under suitable conditions to the momentum of the electron in the target immediately before knockout. Thus the spherically-averaged electron momentum distribution for each molecular orbital is measured. This is directly related to molecular orbitals calculated by the methods of quantum chemistry. Properties obtained by this method for different types of molecules are discussed. 相似文献
17.
Jordan P Leach J Padgett M Blackburn P Isaacs N Goksör M Hanstorp D Wright A Girkin J Cooper J 《Lab on a chip》2005,5(11):1224-1228
We report the creation of permanent 3D configurations of cells, at predefined positions, within a gelatin matrix. The technique used holographic optical tweezers to manipulate individual E. coli within a solution comprising monomer precursors. The matrix was then set and after the laser beam was removed, we were able to demonstrate that the structures remained intact for many days. We were also able to demonstrate that, in the presence of appropriate nutrients, the E. coli survived within the gelatin matrix for several days. The technique could have a number of potential future applications, including the arrangement of a variety of different cell types in complex architectures, as motifs for promoting tissue differentiation and growth within the field of cell engineering. 相似文献
18.
Leach J Wright AJ Götte JB Girkin JM Allen L Franke-Arnold S Barnett SM Padgett MJ 《Physical review letters》2008,100(15):153902
We contrast the two situations in which either a light beam is incident on a moving medium or a moving optical image is incident on a stationary medium. The principle of relativity suggests that the effects on the light of propagating through the medium should be similar. We find, however, that there are subtle differences which we can understand in terms of the relative alignment of the Poynting and wave vectors. Our analysis and experiments investigate both translational motion and rotation. 相似文献
19.
Hughes DA Girkin JM Poland S Longbottom C Button TW Elgoyhen J Hughes H Meggs C Cochran S 《Ultrasonics》2009,49(2):212-218
Dental erosion and decay are increasingly prevalent but as yet there is no quantitative monitoring tool. Such a tool would allow earlier diagnosis and treatment and ultimately the prevention of more serious disease and pain. Despite ultrasound having been demonstrated as a method of probing the internal structures of teeth more than 40 years ago, development of a clinical tool has been slow. The aim of the study reported here was to investigate the use of a novel high frequency ultrasound transducer and validate it using a known dental technique.A tooth extracted for clinical reasons was sectioned to provide a sample that contained an enamel and dentine layer such that the enamel-dentine junction (EDJ) was of a varying depth. The sample was then submerged in water and a B-scan recorded using a custom-designed piezocomposite ultrasound transducer with a centre frequency of 35 MHz and a −6 dB bandwidth of 24 MHz.The transducer has an axial resolution of 180 μm and a spatial resolution of 110 μm, a significant advance on previous work using lower frequencies. The depth of the EDJ was measured from the resulting data set and compared to measurements from the sequential grinding and imaging (SGI) method.The B-scan showed that the EDJ was of varying depth. Subsequently, the EDJ measurements were found to have a correlation of 0.89 (p < 0.01) against the SGI measurements. The results indicate that high frequency ultrasound is capable of measuring enamel thickness to an accuracy of within 10% of the total enamel thickness, whereas currently there is no clinical tool available to measure enamel thickness. 相似文献
20.
本文报导了采用氩离子激光器来泵浦Pr3+:YLF晶体,应用声光调制器实现了主动锁模;同时应用振动─高反射平面镜也实现了被动锁模,两种锁模均得到了ps光脉冲.据作者了解这是这种晶体材料的第一次锁模运转. 相似文献